Re: Default password in Bay Networks switches.

Rolf Obrecht (obrechtIEM.RWTH-AACHEN.DE)
Fri, 12 Mar 1999 12:37:56 +0100

On Thu, 11 Mar 1999, Igor Sviridov wrote:

> On Wed, Mar 10, 1999 at 02:48:58PM -0800, Jan B. Koum wrote:
>
> > 	Ok.. so you would think after 3Com $%#& up last year of inserting
> > 	default password into firmware vendors would learn their lesson?
> > 	[See http://geek-girl.com/bugtraq/1998_2/0340.html for 3com rant]
> >
> > 	Hah! Welcome to the world of strings and Bay Networks firmware
> > 	files. I have looked at some bay networks switches and see that
> > 	the following have default password of "NetICs"
> >
> > BayStack 350T   HW:RevC  FW:V1.01 SW:V1.2.0.10
> > BayStack 350T   HW:RevC  FW:V1.01 SW:V2.0.0.15
>
> Also works on:
>
> BayStack 350T-HD HW:RevA  FW:V1.03 SW:V2.0.2.1	(24 port)
> BayStack 350T    HW:RevC  FW:V1.00 SW:V2.0.2.1	(16 port)
>
> Does not work on:
>
> BayStack 450-24T HW:RevB  FW:V1.04 SW:V1.0.1.0
>
> > -- Yan
>
> --igor
>
Also works on

BayStack 350T HW:RevC  FW:V1.01 SW:V1.03 (16port)

Rolf

---
Rolf Obrecht 			RWTH Aachen
Tel. +49 241 807646		Institut fuer Elektrische Maschinen
Fax  +49 241 8888270		Schinkelstrasse 4, D-52056 Aachen