    * This is a newly released patch... *
    * *
    * Online links can be found at *
    * http://ftp.support.compaq.com/patches/public/vms/axp/v7.1-2/dec-axpvms-vms712_cliutl-v0100--4.README
    *******************************************************************************

    TITLE: OpenVMS VMS712_CLIUTL-V0100 Alpha V7.1-2 CLIUTL ECO Summary

    Modification Date: 17-JAN-2001
    Modification Type: New Kit
     
    NOTE: An OpenVMS saveset or PCSI installation file is stored
           on the Internet in a self-expanding compressed file.
     
           For OpenVMS savesets, the name of the compressed saveset
           file will be kit_name.a-dcx_vaxexe for OpenVMS VAX or
           kit_name.a-dcx_axpexe for OpenVMS Alpha. Once the OpenVMS
           saveset is copied to your system, expand the compressed
           saveset by typing RUN kitname.dcx_vaxexe or kitname.dcx_alpexe.
     
           For PCSI files, once the PCSI file is copied to your system,
           rename the PCSI file to kitname-dcx_axpexe.pcsi, then it can
           be expanded by typing RUN kitname-dcx_axpexe.pcsi. The resultant
           file will be the PCSI installation file which can be used to install
           the ECO.
     

     

    Copyright (c) Compaq Computer Corporation 2000. All rights reserved.

    OP/SYS: OpenVMS Alpha

    COMPONENT: CLIUTL

    SOURCE: Compaq Computer Corporation

    ECO INFORMATION:

         ECO Kit Name: VMS712_CLIUTL-V0100
                        DEC-AXPVMS-VMS712_CLIUTL-V0100--4.PCSI
         ECO Kits Superseded by This ECO Kit: None
         ECO Kit Approximate Size: 2048
         Kit Applies To: OpenVMS Alpha V7.1-2
         System/Cluster Reboot Necessary: No
         Rolling Re-boot Supported: Information Not Available
         Installation Rating: 3

         Kit Dependencies:

           The following remedial kit(s) must be installed BEFORE
           installation of this kit:

               VMS712_UPDATE-V0300
               VMS62TO71U2_PCSI-V0200

           In order to receive all the corrections listed in this
           kit, the following remedial kits should also be installed:

             VMS712_RMS-V0100

    ECO KIT SUMMARY:

    An ECO kit exists for CLIUTL on OpenVMS Alpha V7.1-2. This kit addresses
    the following problems:

    Problems Addressed In VMS712_CLIUTL-V0100:

       o A SET DEVICE/SERVED <TAPEDEV> command may fail with a
           %SYSTEM-F-IVDEVNAM error. This problem could occur when an
           ALPHA system is mistakenly booted with a SYSGEN parameter
           TMSCP_SERVE_ALL = 0. As a result, none of the tape drives are
           served to the cluster clients. Consequently, typing the SET
           DEVICE/SERVED <TAPEDEV> command fails. Since the SYSGEN
           parameter is not dynamic, a reboot of the server is necessary
           to make the tape devices available to the client nodes.

           This change extends functionality of the SET DEVICE/SERVED on
           ALPHA servers to include tape devices.

               Images Affected: [SYSEXE]SET.EXE

     
       o If the $SET AUDIT/SERVER=START command fails, the system
           STARTUP process will hang in a loop waiting for the
           AUDIT_SERVER process to start.

               Images Affected: [SYSEXE]SETAUDIT.EXE

       o When an unprivileged user attempts to access a queue and is
           denied, the event is not alarmed or audited.

               Images Affected: [SYSEXE]SUBMIT.EXE

       o Add a new /CONTENTION_POLICY qualifier to SET RMS_DEFAULT to
           address locking fairness issues.

           The new Alpha global buffer read-mode lock support introduced
           in V7.2-1H1 is functionally compatible with both VAX and older
           Alpha releases. Operations in mixed clusters produce correct
           results. However, there is a locking fairness issue that may
           arise with mixed cluster operations.

           In a mixed cluster environment with very high contention for
           specific buckets, it is possible for accesses to write-shared
           files on nodes using read-mode bucket locking to dominate
           access to a bucket. Nodes without this support might be
           unable to access the bucket for a protracted period of time.
           It is also possible to observe comparable behavior on all
           OpenVMS versions when dealing with accesses to write-shared
           files without global buffers enabled -- even on a standalone
           system. A similar fairness issue between lock conversions and
           new lock requests may be observed in which the new lock
           requests may remain un-granted for an extended period of time.

           This kit provides an interface for RMS support for a new
           option to improve fairness under high contention conditions
           for write-shared files. The option is controlled using the
           /CONTENTION_POLICY qualifier to the DCL command SET
           RMS_DEFAULT. The option may be set at a process or system
           level. Since selecting this option may noticeably increase
           locking overhead and since many applications will never
           encounter this issue, the default system behavior leaves this
           option disabled. A future lock management enhancement should
           make this fairness workaround unnecessary for later releases.

           The following are valid PROCESS keywords (/SYSTEM not
           specified) for SET RMS_DEFAULT/CONTENTION_POLICY:

              NEVER Never use the higher overhead option to
                              improve fairness for any write-shared files
                              accessed by this process; minimal
                              overhead.

              SOMETIMES Use this option for fairer bucket access
                              (but higher overhead) to any write-shared
                              files with global buffers enabled that are
                              accessed by this process.

              ALWAYS Use this option for fairer bucket access
                              (but higher overhead) to all write-shared
                              files accessed by this process.

              SYSTEM_DEFAULT Use system setting. Note that this keyword
                (Default) is disallowed with /SYSTEM.

           The following are valid SYSTEM keywords (/SYSTEM specified):

              NEVER (Default) Never use the higher overhead
                              option to improve fairness for any
                              write-shared files accessed on the system;
                              minimal overhead.

              SOMETIMES Use this option for fairer bucket access
                              (but higher overhead) to any write-shared
                              files with global buffers enabled that are
                              accessed on the system.

              ALWAYS Use this option for fairer bucket access
                              (but higher overhead) to all write-shared
                              files accessed on the system.

              Images Affected: [SYSEXE]SET.EXE

       o SHOW LOGICAL allocates virtual address space based on pagesize
            rather than pagelet size for Alpha only. De-allocation of
            used virtual memory was incorrect.

               Images Affected: [SYSEXE]SHOW.EXE

       o If the virtual-circuit (PB$ path-block) count exceeds four
            times the SCS-node count, a SHOW CLUSTER command will hang on
            startup on cluster nodes with many SCS ports, e.g., CIPCA,
            CIXCD, MC:... or Pxx0: devices. An "SCS-node" is defined as
            any SCS-speaking node, such as HSJxx/HSCxx Storage
            Controllers, RFxx DSSI disk controllers, or VMS nodes, etc.

               Images Affected: [SYSEXE]SHWCLSTR.EXE

     
    INSTALLATION NOTES:

    No reboot is necessary after successful installation of this kit.
    However, users must log out and log back in to use the new features
    provided by this kit.

    Install this kit with the POLYCENTER Software installation utility
    by logging into the SYSTEM account, and typing the following at the
    DCL prompt:

       PRODUCT INSTALL VMS712_CLIUTL /SOURCE=[location of Kit]

    The kit location may be a tape drive, CD, or a disk directory that
    contains the kit.

    Additional help on installing PCSI kits can be found by typing
    HELP PRODUCT INSTALL at the system prompt