Neohapsis is currently accepting applications for employment. For more information, please visit our website www.neohapsis.com or email hr@neohapsis.com |
From: system PRIVILEGED account (root
stage1.cxo.cpqcorp.net)Date: Thu Nov 15 2001 - 02:30:06 CST
*******************************************************************************
* *
* This is a newly released patch... *
* *
* Online links can be found at *
* http://ftp.support.compaq.com/patches/public/vms/axp/v7.3/dec-axpvms-vms73_mount96-v0100--4.README
*******************************************************************************
TITLE: OpenVMS VMS73_MOUNT96-V0100 Alpha V7.3 MOUNT96 ECO Summary
New Kit Date: 15-NOV-2001
Modification Date: Not Applicable
Modification Type: New Kit
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
For OpenVMS savesets, the name of the compressed saveset
file will be kit_name.a-dcx_vaxexe for OpenVMS VAX or
kit_name.a-dcx_axpexe for OpenVMS Alpha. Once the OpenVMS
saveset is copied to your system, expand the compressed
saveset by typing RUN kitname.dcx_vaxexe or kitname.dcx_alpexe.
For PCSI files, once the PCSI file is copied to your system,
rename the PCSI file to kitname-dcx_axpexe.pcsi, then it can
be expanded by typing RUN kitname-dcx_axpexe.pcsi. The resultant
file will be the PCSI installation file which can be used to install
the ECO.
Copyright (c) Compaq Computer Corporation 2001. All rights reserved.
OP/SYS: OpenVMs Alpha
COMPONENT: MOUNT96
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: VMS73_MOUNT96-V0100
DEC-AXPVMS-VMS73_MOUNT96-V0100--4.PCSI
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 736 Blocks
Kit Applies To: OpenVMS Alpha V7.3
System/Cluster Reboot Necessary: No
Rolling Re-boot Supported: Information not available
Installation Rating: INSTALL_3
3 - To be installed on all systems running
the listed versions of OpenVMS which
are experiencing the problems described.
Kit Dependencies:
The following remedial kit(s), or later, must be installed BEFORE
installation of this kit:
None
In order to receive all the corrections listed in this
kit, the following remedial kits, or later, should also be installed:
VMS73_CLIUTL-V0100
VMS73_FIBRE_SCSI-V0200
VMS73_SYS-V0300
ECO KIT SUMMARY:
An ECO kit exists for MOUNT on OpenVMS Alpha V7.3.
This kit addresses the following problems:
PROBLEMS ADDRESSED IN VMS73_MOUNT96-V0100 KIT:
o Roxio CD Creator V5.0 for PCs creates a disk that is not
compliant to the ISO standard. Attempting to mount these
disks on an OpenVMS system will crash the system with an
SSRVEXCEPT, Unexpected system service exception bugcheck.
Crash Dump Summary
------------------
Bugcheck Type: SSRVEXCEPT,
Unexpected system service exception
Current Process: DKA400CACP
Current Image: $82$DKA0:[SYS0.SYSCOMMON.]
[SYSEXE]F11CACP.EXE
Failing PC: FFFFFFFF.800ACD10 EXE$QIO_C+00170
Failing PS: 30000000.00000001
Module: IO_ROUTINES (Link Date/Time:
29-MAR-2000 00:52:23.33)
Offset: 0001AD10
Images Affected: [SYSLIB]MOUNTSHR.EXE
[SYSEXE]VMOUNT.EXE
o When adding a shadow set member with /POLICY=MINICOPY fails,
the error message output is:
-SYSTEM-F-INCSHAMEM, incompatible shadow set member
This error message has been changed to the more descriptive
message:
-MOUNT-F-REQ_WBM_FAIL, unable to add member using minicopy
Images Affected: [SYSLIB]MOUNTSHR.EXE
[SYSEXE]VMOUNT.EXE
o A SET VOLUME/REBUILD command on a volume set may not reset the
volume write count to the correct number of writers in the
cluster. This can occur when a node that had the volume set
mounted did not update the volume write count on dismount or
on a crash. A SHOW DEVICE/REBUILD command always shows this
volume as needing a rebuild. Even a SET VOLUME/REBUILD=FORCE
command will not clear this rebuild status.
Note: To receive this complete change you must also install
the VMS721_CLIUTL-V0200 ECO kit.
Images Affected: [SYSLIB]MOUNTSHR.EXE
o The following problems are corrected:
- A MOUNT/NOWRITE command on a disk on one cluster will now
work correctly, even if the disk is mounted with a /WRITE
qualifier on another cluster in the SAN (Storage Area
Network). Previously, depending on the order in which the
mount commands were executed, the mount would fail with
the error message:
DIFVOLMNT - different volume already mounted on this
device.
- If a disk is mounted with a /WRITE qualifier on one
cluster and a /NOWRITE qualifier on another cluster in the
SAN, mount verification will fail with a WrongVolume
status error on the system which had the disk mounted
/NOWRITE. This change allows mount verification to
complete successfully in this configuration.
Note: To receive this complete correction you must also install
the VMS721_SYS-V1100 and VMS721_FIBRE_SCSI-V0500 ECO
kits.
Images Affected: [SYSLIB]MOUNTSHR.EXE
[SYSEXE]VMOUNT.EXE
o Read failures during a disk mount that were due to an
inability to read the home block and failures that were due to
transient errors, such as from a path switch or SCSI bus
reset, were following the same failure path. That is, reading
the alternate home block and if successful, mounting the disk
as read only. However, failures due to transient errors
should not read the alternate home block and should mount the
disk as READ/WRITE.
For transient error failures, this change will now cause the
READ to be re-tried for 30 seconds (30 re-tries at one per
second). If the READ succeeds, the disk will be mounted as
READ/WRITE.
Images Affected: [SYSEXE]VMOUNT.EXE
[SYSLIB]MOUNTSHR.EXE
INSTALLATION NOTES:
No reboot is necessary after successful installation of the kit.
Install this kit with the POLYCENTER Software installation utility
by logging into the SYSTEM account, and typing the following at the
DCL prompt:
PRODUCT INSTALL VMS73_MOUNT96 /SOURCE=[location of Kit]
The kit location may be a tape drive, CD, or a disk directory that
contains the kit.
Additional help on installing PCSI kits can be found by typing
HELP PRODUCT INSTALL at the system prompt
SPECIAL INSTALLATION INSTRUCTIONS:
o Image Installation
If you have other nodes in your VMScluster, an INSTALL/REPLACE
command will need to be issued on each node in order to make
use of the images in this kit. The commands needed are:
INSTALL/REPLACE SYS$SHARE:MOUNTSHR.EXE/SHARE/OPEN/HEADER/PROT
INSTALL REPLACE SYS$SYSTEM:VMOUNT.EXE
o Scripting of Answers to Installation Questions
During installation, this kit will ask and require user
response to several questions. If you wish to automate the
installation of this kit and avoid having to provide responses
to these questions, you must create a DCL command procedure
that includes the following definitions and commands:
1. Define logical NO_ASK$BACKUP as TRUE
2. Define logical NO_ASK$REBOOT as TRUE
3. Add the following qualifiers to the PRODUCT INSTALL
command and add that command to the DCL procedure.
/PROD=DEC/BASE=AXPVMS/VER=V1.0
4. De-assign the logicals assigned
For example, a sample command file to install the
VMS73_MOUNT96-V0100 kit would be:
$ DEFINE/SYS NO_ASK$BACKUP TRUE
$!
$ PROD INSTALL VMS73_MOUNT96/PROD=DEC/BASE=AXPVMS/VER=V1.0
$!
$ DEASSIGN/SYS NO_ASK$BACKUP
$ exit
All trademarks are the property of their respective owners.
---
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]