OSEC

Neohapsis is currently accepting applications for employment. For more information, please visit our website www.neohapsis.com or email hr@neohapsis.com
 
From: system PRIVILEGED account (rootstage1.cxo.cpqcorp.net)
Date: Thu Nov 15 2001 - 02:30:06 CST

  • Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]

    *******************************************************************************
    * *
    * This is a newly released patch... *
    * *
    * Online links can be found at *
    * http://ftp.support.compaq.com/patches/public/vms/axp/v7.3/dec-axpvms-vms73_mount96-v0100--4.README
    *******************************************************************************

    TITLE: OpenVMS VMS73_MOUNT96-V0100 Alpha V7.3 MOUNT96 ECO Summary

    New Kit Date: 15-NOV-2001
    Modification Date: Not Applicable
    Modification Type: New Kit
     
    NOTE: An OpenVMS saveset or PCSI installation file is stored
           on the Internet in a self-expanding compressed file.
     
           For OpenVMS savesets, the name of the compressed saveset
           file will be kit_name.a-dcx_vaxexe for OpenVMS VAX or
           kit_name.a-dcx_axpexe for OpenVMS Alpha. Once the OpenVMS
           saveset is copied to your system, expand the compressed
           saveset by typing RUN kitname.dcx_vaxexe or kitname.dcx_alpexe.
     
           For PCSI files, once the PCSI file is copied to your system,
           rename the PCSI file to kitname-dcx_axpexe.pcsi, then it can
           be expanded by typing RUN kitname-dcx_axpexe.pcsi. The resultant
           file will be the PCSI installation file which can be used to install
           the ECO.
     

     

    Copyright (c) Compaq Computer Corporation 2001. All rights reserved.

    OP/SYS: OpenVMs Alpha

    COMPONENT: MOUNT96

    SOURCE: Compaq Computer Corporation

    ECO INFORMATION:

         ECO Kit Name: VMS73_MOUNT96-V0100
                        DEC-AXPVMS-VMS73_MOUNT96-V0100--4.PCSI
         ECO Kits Superseded by This ECO Kit: None
         ECO Kit Approximate Size: 736 Blocks
         Kit Applies To: OpenVMS Alpha V7.3
         System/Cluster Reboot Necessary: No
         Rolling Re-boot Supported: Information not available
         Installation Rating: INSTALL_3
                                3 - To be installed on all systems running
                                    the listed versions of OpenVMS which
                                    are experiencing the problems described.

         Kit Dependencies:

           The following remedial kit(s), or later, must be installed BEFORE
           installation of this kit:

             None

           In order to receive all the corrections listed in this
           kit, the following remedial kits, or later, should also be installed:

             VMS73_CLIUTL-V0100
             VMS73_FIBRE_SCSI-V0200
             VMS73_SYS-V0300

    ECO KIT SUMMARY:

    An ECO kit exists for MOUNT on OpenVMS Alpha V7.3.
    This kit addresses the following problems:

    PROBLEMS ADDRESSED IN VMS73_MOUNT96-V0100 KIT:

      o Roxio CD Creator V5.0 for PCs creates a disk that is not
         compliant to the ISO standard. Attempting to mount these
         disks on an OpenVMS system will crash the system with an
         SSRVEXCEPT, Unexpected system service exception bugcheck.

         Crash Dump Summary
         ------------------
         Bugcheck Type: SSRVEXCEPT,
                            Unexpected system service exception
         Current Process: DKA400CACP
         Current Image: $82$DKA0:[SYS0.SYSCOMMON.]
                            [SYSEXE]F11CACP.EXE
         Failing PC: FFFFFFFF.800ACD10 EXE$QIO_C+00170
         Failing PS: 30000000.00000001
         Module: IO_ROUTINES (Link Date/Time:
                                            29-MAR-2000 00:52:23.33)
         Offset: 0001AD10

              Images Affected: [SYSLIB]MOUNTSHR.EXE
                                [SYSEXE]VMOUNT.EXE

      o When adding a shadow set member with /POLICY=MINICOPY fails,
         the error message output is:

           -SYSTEM-F-INCSHAMEM, incompatible shadow set member
                 
         This error message has been changed to the more descriptive
         message:

           -MOUNT-F-REQ_WBM_FAIL, unable to add member using minicopy

              Images Affected: [SYSLIB]MOUNTSHR.EXE
                                [SYSEXE]VMOUNT.EXE

      o A SET VOLUME/REBUILD command on a volume set may not reset the
         volume write count to the correct number of writers in the
         cluster. This can occur when a node that had the volume set
         mounted did not update the volume write count on dismount or
         on a crash. A SHOW DEVICE/REBUILD command always shows this
         volume as needing a rebuild. Even a SET VOLUME/REBUILD=FORCE
         command will not clear this rebuild status.

         Note: To receive this complete change you must also install
               the VMS721_CLIUTL-V0200 ECO kit.

              Images Affected: [SYSLIB]MOUNTSHR.EXE

      o The following problems are corrected:

          - A MOUNT/NOWRITE command on a disk on one cluster will now
             work correctly, even if the disk is mounted with a /WRITE
             qualifier on another cluster in the SAN (Storage Area
             Network). Previously, depending on the order in which the
             mount commands were executed, the mount would fail with
             the error message:

             DIFVOLMNT - different volume already mounted on this
                         device.
     
          - If a disk is mounted with a /WRITE qualifier on one
             cluster and a /NOWRITE qualifier on another cluster in the
             SAN, mount verification will fail with a WrongVolume
             status error on the system which had the disk mounted
             /NOWRITE. This change allows mount verification to
             complete successfully in this configuration.

         Note: To receive this complete correction you must also install
               the VMS721_SYS-V1100 and VMS721_FIBRE_SCSI-V0500 ECO
               kits.

              Images Affected: [SYSLIB]MOUNTSHR.EXE
                                [SYSEXE]VMOUNT.EXE

      o Read failures during a disk mount that were due to an
         inability to read the home block and failures that were due to
         transient errors, such as from a path switch or SCSI bus
         reset, were following the same failure path. That is, reading
         the alternate home block and if successful, mounting the disk
         as read only. However, failures due to transient errors
         should not read the alternate home block and should mount the
         disk as READ/WRITE.

         For transient error failures, this change will now cause the
         READ to be re-tried for 30 seconds (30 re-tries at one per
         second). If the READ succeeds, the disk will be mounted as
         READ/WRITE.

              Images Affected: [SYSEXE]VMOUNT.EXE
                                [SYSLIB]MOUNTSHR.EXE

    INSTALLATION NOTES:

    No reboot is necessary after successful installation of the kit.

    Install this kit with the POLYCENTER Software installation utility
    by logging into the SYSTEM account, and typing the following at the
    DCL prompt:

         PRODUCT INSTALL VMS73_MOUNT96 /SOURCE=[location of Kit]

    The kit location may be a tape drive, CD, or a disk directory that
    contains the kit.

    Additional help on installing PCSI kits can be found by typing
    HELP PRODUCT INSTALL at the system prompt

    SPECIAL INSTALLATION INSTRUCTIONS:

      o Image Installation

         If you have other nodes in your VMScluster, an INSTALL/REPLACE
         command will need to be issued on each node in order to make
         use of the images in this kit. The commands needed are:

         INSTALL/REPLACE SYS$SHARE:MOUNTSHR.EXE/SHARE/OPEN/HEADER/PROT

         INSTALL REPLACE SYS$SYSTEM:VMOUNT.EXE

      o Scripting of Answers to Installation Questions

         During installation, this kit will ask and require user
         response to several questions. If you wish to automate the
         installation of this kit and avoid having to provide responses
         to these questions, you must create a DCL command procedure
         that includes the following definitions and commands:

           1. Define logical NO_ASK$BACKUP as TRUE

           2. Define logical NO_ASK$REBOOT as TRUE

           3. Add the following qualifiers to the PRODUCT INSTALL
               command and add that command to the DCL procedure.

               /PROD=DEC/BASE=AXPVMS/VER=V1.0

           4. De-assign the logicals assigned

         For example, a sample command file to install the
         VMS73_MOUNT96-V0100 kit would be:

              $ DEFINE/SYS NO_ASK$BACKUP TRUE
              $!
              $ PROD INSTALL VMS73_MOUNT96/PROD=DEC/BASE=AXPVMS/VER=V1.0
              $!
              $ DEASSIGN/SYS NO_ASK$BACKUP
              $ exit

    All trademarks are the property of their respective owners.

    ---