OSEC

Neohapsis is currently accepting applications for employment. For more information, please visit our website www.neohapsis.com or email hr@neohapsis.com
 
From: system PRIVILEGED account (rootstage1.cxo.cpqcorp.net)
Date: Tue Apr 16 2002 - 02:30:04 CDT

  • Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]

    *******************************************************************************
    * *
    * This is an update to an existing patch... *
    * *
    * Online links can be found at *
    * http://ftp.support.compaq.com/patches/public/vms/axp/v7.2-1/dec-axpvms-vms721_fibre_scsi-v0500--4.README
    *******************************************************************************

    TITLE: OpenVMS VMS721_FIBRE_SCSI-V0500 Alpha V7.2-1 FibreChannel/SCSI ECO Summary
     
    NOTE: An OpenVMS saveset or PCSI installation file is stored
           on the Internet in a self-expanding compressed file.
     
           For OpenVMS savesets, the name of the compressed saveset
           file will be kit_name.a-dcx_vaxexe for OpenVMS VAX or
           kit_name.a-dcx_axpexe for OpenVMS Alpha. Once the OpenVMS
           saveset is copied to your system, expand the compressed
           saveset by typing RUN kitname.dcx_vaxexe or kitname.dcx_alpexe.
     
           For PCSI files, once the PCSI file is copied to your system,
           rename the PCSI file to kitname-dcx_axpexe.pcsi, then it can
           be expanded by typing RUN kitname-dcx_axpexe.pcsi. The resultant
           file will be the PCSI installation file which can be used to install
           the ECO.
     

     
    Copyright (c) Compaq Computer Corporation 2000, 2001. All rights reserved.

    New Kit Date: 31-OCT-2001
    Modification Date: 16-APR-2002
    Modification Type: Note added about kit installation.

    OP/SYS: OpenVMS Alpha

    COMPONENT: FibreChannel
                SCSI Drivers

    SOURCE: Compaq Computer Corporation

    ECO INFORMATION:

         ECO Kit Name: VMS721_FIBRE_SCSI-V0500
                         DEC-AXPVMS-VMS721_FIBRE_SCSI-V0500--4.PCSI
         ECO Kits Superseded by This ECO Kit: None
         ECO Kit Approximate Size: 4608 Blocks
         Kit Applies To: OpenVMS Alpha V7.2-1
         System/Cluster Reboot Necessary: Yes
         Rolling Re-boot Supported: Yes
         Installation Rating: INSTALL_1
                               To be installed by all customers.

         Kit Dependencies:

           The following remedial kit(s), or later, must be installed BEFORE
           installation of this kit:

              VMS721_PCSI-V0100
              VMS721_UPDATE-V0300
              
           In order to receive all the corrections listed in this
           kit, the following remedial kits, or later, should also be installed:

             VMS721_SYS-V1100
             VMS721_MOUNT96-V0300

    ECO KIT SUMMARY:

    An ECO kit exists for FibreChannel and SCSI Drivers on OpenVMS Alpha
    V7.2-1. This kit addresses the following problems:

    PROBLEMS ADDRESSED IN VMS721_FIBRE_SCSI-V0500 KIT:

      o If an MCR SYMAN IO AUTO command is issued to hot add/ swap
         SCSI targets, there is a possibility that a system can
         experience a hang.

           Images Affected: [SYS$LDR]SYS$PKADRIVER.EXE

      o A system can experience excessive SCSI bus resets due to
         un-synchronized access to device registers.

           Images Affected: [SYS$LDR]SYS$PKWDRIVER.EXE

      o Tape Density values are not stored correctly. This causes
         third party tape applications, such as Oracle's RMU backup
         utility, to fail when performing multi-volume tape backup and
         other operations which require the tape density to be stored
         correctly.

           Images Affected: [SYS$LDR]SYS$MKDRIVER.EXE

      o The system can hang due to IO's Timing Out, and the driver not
         re-trying the IO command. The IO timeout can be detected
         through the error log.

           Images Affected: [SYS$LDR]SYS$PKADRIVER.EXE

      o On OpenVMS Alpha clusters sharing a SCSI bus and attached to
         the bus with KZPBA SCSI controllers, disks may not come out of
         Mount Verify.

           Images Affected: [SYS$LDR]SYS$PKQDRIVER.EXE

      o When performing multi-volume Backup (and various other Backup
         operations involving label processing) with generic SCSI
         tapes, compaction status gets turned off.

           Images Affected: [SYS$LDR]SYS$MKDRIVER.EXE

      o Odd byte records read from tape to a memory buffer larger than
         the tape record results in one extra byte of data.

           Images Affected: [SYS$LDR]SYS$PKWDRIVER.EXE

      o When an HSZ/HSG device reports mirror copy status events, the
         ERRCNT of the device is incremented. This gives the false
         impression that there is a problem with the device(s).

           Images Affected: [SYS$LDR]SYS$DKDRIVER.EXE

      o In a multiprocessor environment, exception conditions (such as
         AUTOGEN, disk errors, power glitches, etc.) cause the
         PKWDRIVER, the hardware interface, and the script code to
         become un-synchronized relative to each other. This lack of
         synchronization can cause excessive bus resets, mount verify
         timeouts, command timeouts, I/O system hangs, system crashes
         and/or file corruption. The most obvious problem is the
         occurrence of SCSI bus resets. These can be seen with a "SHOW
         ERROR" command and will be in the error log.

           Images Affected: [SYS$LDR]SYS$PKWDRIVER.EXE

      o Tape drive performance degrades significantly after a tape
         error.

           Images Affected: [SYS$LDR]SYS$MKDRIVER.EXE

      o If a disk is mounted software write protected, when the disk
         enters and completes mount verification, the disk is software
         write enabled.

           Images Affected: [SYS$LDR]SYS$DKDRIVER.EXE

      o A system can crash with an INVEXCEPTN, Exception while above
         ASTDEL bugcheck.

         Crashdump Summary Information:
         ------------------------------
         Bugcheck Type: INVEXCEPTN, Exception while above ASTDEL
         Current Process: NULL
         Current Image: <not available>
         Failing PC: FFFFFFFF.802FB820 SCS$POLL_MODE_C+00460
         Failing PS: 1C000000.00000804
         Module: SYS$SCS (Link Date/Time:
                            9-DEC-2000 00:44:16.18)
         Offset: 00005820

           Images Affected: [SYS$LDR]SYS$PGADRIVER.EXE

      o A system can experience CPUSPINWAIT Crashes. See Crash dump
         summary below.

         Crashdump Summary Information:
         ------------------------------
         Bugcheck Type: CPUSPINWAIT, CPU spinwait timer
                            expired
         Current Process: NULL
         Current Image: <not available>
         Failing PC: FFFFFFFF.80088384
                            SMP$TIMEOUT_C+00064
         Failing PS: 18000000.00000804
         Module: SYSTEM_SYNCHRONIZATION_MIN
                            (Link Date/Time: 26-MAY-2001 22:21:11.81)
         Offset: 00000384

           Images Affected: [SYS$LDR]SYS$PKQDRIVER.EXE

      o For 8MM tapes (for example Exabyte, TZK15), a COPY command to
         a freshly initialized tape results in a fatal drive error
         whenever the COPY command is issued on a TMSCP client node.
         The error log will show that an Illegal Request has been sent
         to the drive.

           Images Affected: [SYS$LDR]SYS$MKDRIVER.EXE

      o Mounting CDs in the Yamaha CD-Writer CRW8424S results in a
         '%MOUNT-F-FORMAT, invalid media format' error message.

           Images Affected: [SYS$LDR]SYS$DKDRIVER.EXE

      o When booting, a shadowed system disk can hang the cluster.

           Images Affected: [SYS$LDR]SYS$DKDRIVER.EXE

    INSTALLATION NOTES:

    *******************************************************************
    * NOTE *
    * During kit installation, the SMI$OBJSHR.EXE image is installed *
    * in the SYS$COMMON:[SYS$LDR] directory. After kit installation *
    * completes but before rebooting the system, you must rename the *
    * SMI$OBJSHR.EXE image to the SYS$COMMON:[SYSLIB] directory. *
    * *
    *******************************************************************

    This kit requires a system reboot. Compaq strongly recommends that
    a reboot is performed immediately after kit installation to avoid
    system instability

    If you have other nodes in your OpenVMS cluster, they must also be
    rebooted in order to make use of the new image(s). If it is not
    possible or convenient to reboot the entire cluster at this time, a
    rolling re-boot may be performed.

    INSTALLATION INSTRUCTION:

    Install this kit with the POLYCENTER Software installation utility
    by logging into the SYSTEM account, and typing the following at the
    DCL prompt:

    PRODUCT INSTALL VMS721_FIBRE_SCSI /SOURCE=[location of Kit]

    The kit location may be a tape drive, CD, or a disk directory that
    contains the kit.

    Additional help on installing PCSI kits can be found by typing
    HELP PRODUCT INSTALL at the system prompt

    SPECIAL INSTALLATION INSTRUCTIONS:

      o Scripting of Answers to Installation Questions

         During installation, this kit will ask and require user
         response to several questions. If you wish to automate the
         installation of this kit and avoid having to provide responses
         to these questions, you must create a DCL command procedure
         that includes the following definitions and commands:

           1. Define logical NO_ASK$BACKUP as TRUE

           2. Define logical NO_ASK$REBOOT as TRUE

           3. Add the following qualifiers to the PRODUCT INSTALL
               command and add that command to the DCL procedure.

               /PROD=DEC/BASE=AXPVMS/VER=V5.0

           4. De-assign the logicals assigned

         For example, a sample command file to install the
         VMS721_FIBRE_SCSI-V0500 kit would be:

              $ DEFINE/SYS NO_ASK$BACKUP TRUE
              $ DEFINE/SYS NO_ASK$REBOOT TRUE
              $!
              $ PROD INSTALL VMS721_FIBRE_SCSI/PROD=DEC/BASE=AXPVMS/VER=V5.0
              $!
              $ DEASSIGN/SYS NO_ASK$BACKUP
              $ DEASSIGN/SYS NO_ASK$REBOOT
              $ exit

    All trademarks are the property of their respective owners.

    ---