    Hi,

    Thanks Peter for your great explanation.
     
    > 7816-3:1997 section 8.2 on work waiting time:
    >
    > wwt = 960 * WI * (Fi / f)
    >

    This is exactly what I get doning variable
    substitution and symplification in the formula that
    comes in ISO 7816-3: 1992.

    [snip]

    > It seems, therefore, that changing the value of Di
    > in the ATR does not
    > change the value of the wwt, but changing the value
    > of Fi does. Is this what
    > the writers of 7816-3:1997 meant? I don't think so,
    > because the wwt required
    > is related to the values of clock sent to the card,
    > the internal structure
    > of the card's CPU and clock processing circuits, and
    > the application
    > algorithm programmed into the card. Changing Fi and
    > Di doesn't change the
    > way that the card runs its application code, and so
    > should not change the
    > wwt - but changing Fi does change the wwt.
    >
    > FI from the card, besides influencing I/O bit rate,
    > also indicates the max
    > clock frequency that the card can be run at. So:
    >
    > FI = 0 (means Fi = 372), Di = 1 gives a bit rate of
    > 9600 in our example, a
    > wwt of 1 sec, and indicates (Table 7) a max clock
    > frequency of 4 MHz
    > (typical for a card run at 3 Volts Vcc)
    >
    > FI = 1 (also means Fi = 372), Di = 1 gives a bit
    > rate of 9600 in our
    > example, a wwt of 1 sec, and indicates (Table 7) a
    > max clock frequency of 5
    > MHz (typical for a low cost card run at 5 Volts Vcc)
    >
    > FI = 3 (means Fi = 744), Di = 2 also gives a bit
    > rate of 9600 in our
    > example, but changes the wwt to 2 sec, and indicates
    > (Table 7) a max clock
    > frequency of 8 MHz (e.g. for a Hitachi 3109 card as
    > used by "rollout spec"
    > Mondex in a single application environment)
    >

    But the reader that I'm ussing provides 3.5712 MHz
    constant clock rate to the smartcard regardless of the
    ATR in the card.

    So, must I assume that if the clock rate doesn't
    change I must not change the wwt from the standard 1s
    value ?

    Does this apply to T=1 timeout values, BWT and CWT?

    Thanks,
    Carlos.

    __________________________________________________
    Do You Yahoo!?
    Get personalized email addresses from Yahoo! Mail - only $35
    a year! http://personal.mail.yahoo.com/
    ***************************************************************
    Linux Smart Card Developers - M.U.S.C.L.E.
    (Movement for the Use of Smart Cards in a Linux Environment)
    http://www.linuxnet.com/smartcard/index.html
    ***************************************************************