Neohapsis is currently accepting applications for employment. For more information, please visit our website www.neohapsis.com or email hr@neohapsis.com |
Re: [Muscle] help figuring out reader protocol
From: Chaskiel M Grundman (cg2v
andrew.cmu.edu)
Date: Sat Apr 09 2005 - 10:56:59 CDT
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
--On Saturday, April 09, 2005 05:46:12 PM +0900 Nikolay Elenkov
<nick
wd6.so-net.ne.jp> wrote:
This looks like raw T=1 protocol to me.
> 000080 B> 00000000: 04 0000 0490 0102 0097
NAD = 0 (no logical channels)
PCB = 0 (I_BLOCK; seq=0)
LEN = 4
Info = 90 01 02 00
epilogue = 97, the LRC (simple XOR) checksum of all the previous bytes
> 000081 B< 00000000: 04 0000 026e 006c
NAD = 0 (no logical channels)
PCB = 0 (I_BLOCK; seq=0)
LEN = 2
Info = 6e00
epilogue = 6c, the LRC (simple XOR) checksum of all the previous bytes
> 000082 B> 00000000: 04 0040 0490 0102 01d6
NAD = 0 (no logical channels)
PCB = 40 (I_BLOCK; seq=1)
LEN = 4
Info = 90 01 02 01
epilogue = d6, the LRC (simple XOR) checksum of all the previous bytes
> 000083 B< 00000000: 04 0040 026e 002c
NAD = 0 (no logical channels)
PCB = 40 (I_BLOCK; seq=1)
LEN = 2
Info = 6e00
epilogue = 2c, the LRC (simple XOR) checksum of all the previous bytes
etc.
_______________________________________________
Muscle mailing list
Muscle
lists.musclecard.com
http://lists.drizzle.com/mailman/listinfo/muscle
- application/pkcs7-signature attachment: stored