From: Ludovic Rousseau (ludovic.rousseau
gmail.com)
Date: Tue Jul 29 2008 - 04:28:40 CDT
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
On Sun, Jul 20, 2008 at 9:37 AM, Harald Milz <hm
seneca.muc.de> wrote:
> Hi,
Hello,
> Q1: does pcscd support talking to multiple pcsc clients at the same time?
> If yes, is there an architectural limit how many?
Yes. 16 by default.
> Q2: on the pcsc client level, how do I tell the smartcard readers apart
> when they are the same make and model, in order to build the proper
> rdesktop command for each user?
You can't, unless each reader has a (different) USB serial number.
Only a minority of smart card readers have a serial number.
> Q3: has any progress been made as far as access security? In 2006 there
> were talks about running pcscd against PAM. Would that include separating
> card readers from each other, and allowing a user to see only her/his
> reader?
I am still waiting for patches :-)
Maybe your company wants to sponsor this development?
Regards,
--
Dr. Ludovic Rousseau
_______________________________________________