Neohapsis is currently accepting applications for employment. For more information, please visit our website www.neohapsis.com or email hr@neohapsis.com |
From: IT Resource Center (support_feedback
us-support.external.hp.com)Date: Sun Jan 14 2001 - 05:48:48 CST
HP Support Information Digests
===============================================================================
o IT Resource Center World Wide Web Service
---------------------------------------------------
If you subscribed through the IT Resource Center and would
like to be REMOVED from this mailing list, access the
IT Resource Center on the World Wide Web at:
Login using your IT Resource Center User ID and Password.
Then select Support Information Digests (located under
Maintenance and Support). You may then unsubscribe from the
appropriate digest.
To download a patch referenced below, access the
IT Resource Center on the World Wide Web at:
Login using your IT Resource Center User ID and Password.
Then select Individual Patches (under Maintenance and Support)
to access the patch. You may also download a patch via anonymous
ftp(1) from ftp.itrc.hp.com.
===============================================================================
Digest Name: weekly all firmware patch digest
Created: Sun Jan 14 3:05:02 PST 2001
Table of Contents:
Document ID Title
--------------- -----------
PF_CV220108 SPP.PDC revision 3.0.2 firmware patch
The documents are listed below.
-------------------------------------------------------------------------------
Document ID: PF_CV220108
Date Loaded: 20010109
Title: SPP.PDC revision 3.0.2 firmware patch
Patch Name: PF_CV220108
Patch Description: SPP.PDC revision 3.0.2 firmware patch
- Fixes an DMPF (data memory protection fault) in the LPMC handler
Path Name: /firmware_patches/hp/cpu/PF_CV220108
Creation Date: 01/01/04
Post Date: 01/01/09
SR: None
sum(1) Output: 5880 441 CV220108.frm
Hardware Dependencies: SPP2XXX
Software Dependencies: Exemplar Diagnostic Version 5.2, 5.2.1, or 5.2.2
Supersedes: None
Patch Package Size (Kbytes): 220
Installation Instructions:
Please review all instructions and the Hewlett-Packard
Support Line User Guide or your Hewlett-Packard support terms
and conditions for precautions, scope of license,
restrictions, and, limitation of liability and warranties,
before installing this patch.
Read all of these instructions before proceeding with the update.
Printing these instructions will be helpful.
* * * * * * SIDE AFFECTS FROM UPDATING YOUR FIRMWARE * * * * * * *
* None
* * * * * * * * * * * FIXES IN THIS PATCH * * * * * * * * * * * *
SPP_PDC:
An error in the LPMC handler code will sometimes cause
a Data Memory Protection Fault and a panic.
* * * * * * * IDENTIFY CURRENT VERSION OF FIRMWARE * * * * * * *
Prior to performing the firmware update, verify the current
version of your firmware, using the following steps:
Step 1. In a diagnostic window on the Test Station of your
system execute the following command:
diag_version
Identify the diagnostic revision. The output from the
above command should be one of the following:
Exemplar Diagnostics, Version 5.2
Exemplar Diagnostics, Version 5.2.2
Exemplar Diagnostics, Version 5.2.1
If not then do not proceed with this update.
* * * * * * * * MOVING FIRMWARE TO CORRECT DIRECTORY * * * * * * *
Step 1. Install the new PDC firmware in the correct directory
by executing the following commands in any diagnostic
window on the Test Station:
mv -f /spp/firmware/spp.pdc /spp/firmware/spp.pdc_301
mv CV220108.frm /spp/firmware/spp.pdc
Step 2. Verify that the permissions and user/group ids are properly set
on the file /spp/firmware/spp.pdc. The user and group must be
set to sppuser. Change the user/group with the following commands:
chown sppuser /spp/firmware/spp.pdc
chgrp sppuser /spp/firmware/spp.pdc
The file permissions should be at least 0444. Change the
permission with the following command:
chmod 0444 /spp/firmware/spp.pdc
The file permissions/ownership should look like this when you
are finished.
-r--r--r-- 1 sppuser sppuser 225464 Jan 24 2000 spp.pdc
Step 3. Verify that you are installing the correct version by SPP_PDC
by executing the following command in any diagnostic
window on the Test Station:
what /spp/firmware/spp.pdc
The output should read (the date/time may differ):
/spp/firmware/spp.pdc:
SPP_PDC (64-bit) Release 3.0.2 (01/04/01 13:38:14)
* * * * * * * * * * FIRMWARE UPDATE PROCEDURE * * * * * * * * * *
Step 1. If your system is at the OS level then shutdown the
system via the /etc/shutdown command to the OBP prompt.
When the system completes the shutdown process, either
the "Command: " or "[] ok " prompt should be displayed
in the console window.
Step 2. If the "Command: " prompt is displayed then execute the
following command to switch to the Forth interface:
fm
Step 3. Execute the following commands at the OBP prompt:
fwcp 15.99.111.99:/spp/firmware/spp.pdc spp_pdc
Step 4. Now reset the system by executing the command:
reset
and wait for the OBP prompt.
Step 5. Now boot the system as normal. The Banner should show
that SPP_PDC 3.0.2 is installed, and it should look like
this:
SPP_PDC (64-bit) Release 3.0.2 (01/04/01 13:38:14)
* * * * * * END OF UPDATE * * * * * *
-----End of Document ID: PF_CV220108-----------------------------------------
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]