Neohapsis is currently accepting applications for employment. For more information, please visit our website www.neohapsis.com or email hr@neohapsis.com |
From: IT Resource Center (support_feedback_at_us-support2-mail.external.hp.com)
Date: Sun Jan 12 2003 - 13:41:41 CST
HP Support Information Digests
===============================================================================
o IT Resource Center World Wide Web Service
---------------------------------------------------
If you subscribed through the IT Resource Center and would
like to be REMOVED from this mailing list, access the
IT Resource Center on the World Wide Web at:
Login using your IT Resource Center User ID and Password.
Then select Support Information Digests (located under
Maintenance and Support). You may then unsubscribe from the
appropriate digest.
To download a patch referenced below, access the
IT Resource Center on the World Wide Web at:
Login using your IT Resource Center User ID and Password.
Then select Individual Patches (under Maintenance and Support)
to access the patch. You may also download a patch via anonymous
ftp(1) from ftp.itrc.hp.com.
===============================================================================
Digest Name: weekly MPE/iX 6.0 patch digest
Created: Sun Jan 12 6:05:21 EST 2003
Table of Contents:
Document ID Title
--------------- -----------
OSPMX35A Pred stops configuring if pdev>16,memscan aborts if Colossu
The documents are listed below.
-------------------------------------------------------------------------------
Document ID: OSPMX35A
Date Loaded: 20030106
Title: Pred stops configuring if pdev>16,memscan aborts if Colossu
Pred stops configuring if pdev>16,memscan aborts if Colossu
BY: MEL ROBERTSON - CSY Patch Coordinator
Patch Name: OSPMX35A
Path Name: /mpe-ix_patches/c.60.00/OSPMX35A
Patch Description: Pred stops configuring if pdev>16,memscan aborts if Colossu
Last Updated: 01/04/03
Date Entered: 12/13/01
Patch Status: Patch is General Release
SR Number:
8606-230470 8606-178548
Dependency SCO:
ODILXA9 A
Patch Files:
ORGFILE TARGFILE PATCH TYPE
------------------------------------------------------------------
P00MX35A.OSPMX35A.PATCHIX PSMON.PRED.SYS RP
R00MX35A.OSPMX35A.PATCHIX XL.PRED.SYS NC
P01MX35A.OSPMX35A.PATCHIX PSMONX.PRED.SYS RP
C01MX35A.OSPMX35A.PATCHIX CPSMG00X.PRED.SYS RP
P04MX35A.OSPMX35A.PATCHIX PSRULEUP.PRED.SYS RP
P05MX35A.OSPMX35A.PATCHIX DISCSCNP.PRED.SYS RP
P06MX35A.OSPMX35A.PATCHIX LOGSCANP.PRED.SYS RP
P08MX35A.OSPMX35A.PATCHIX SCSISCNP.PRED.SYS RP
P09MX35A.OSPMX35A.PATCHIX PSUXFDMP.PRED.SYS RP
P10MX35A.OSPMX35A.PATCHIX PSUXFRDP.PRED.SYS RP
P13MX35A.OSPMX35A.PATCHIX PSSWINVP.PRED.SYS RP
P14MX35A.OSPMX35A.PATCHIX PTRACKP.PRED.SYS RP
P17MX35A.OSPMX35A.PATCHIX SKEWRUN.PSTEMPDB.SYS AD
P20MX35A.OSPMX35A.PATCHIX DISKTRKP.PRED.SYS RP
P21MX35A.OSPMX35A.PATCHIX PSCPUNAM.PRED.SYS RP
Z21MX35A.OSPMX35A.PATCHIX PREDICTA.PRED.SYS RP
Z24MX35A.OSPMX35A.PATCHIX PSDCTSTD.PRED.SYS NC
Z30MX35A.OSPMX35A.PATCHIX PSDBUP.PSTEMPDB.SYS AD
Z81MX35A.OSPMX35A.PATCHIX TXTRCTSH.PRED.SYS AD
Z82MX35A.OSPMX35A.PATCHIX TEXTRACT.PRED.SYS AD
IHFMX35A.OSPMX35A.PATCHIX I01I779A.USL.SYS
B00MX35A.OSPMX35A.PATCHIX
C00MX35A.OSPMX35A.PATCHIX CPSMG000.PRED.SYS RP
GENMX35A.OSPMX35A.PATCHIX
REFMX35A.OSPMX35A.PATCHIX
OSPMX35A.OSPMX35A.PATCHIX
AUTOPAT.HP31900A.PATCHXL
P16MX35A.OSPMX35A.PATCHIX PSDBCONP.PSTEMPDB.SYS AD
Z66MX35A.OSPMX35A.PATCHIX PSDBUP1.PSTEMPDB.SYS AD
Z31MX35A.OSPMX35A.PATCHIX PSDBUP2.PSTEMPDB.SYS AD
Z32MX35A.OSPMX35A.PATCHIX PSDBUP3.PSTEMPDB.SYS AD
Z33MX35A.OSPMX35A.PATCHIX PSDBUP4.PSTEMPDB.SYS AD
Z69MX35A.OSPMX35A.PATCHIX PSDBUP5.PSTEMPDB.SYS AD
Z74MX35A.OSPMX35A.PATCHIX PSDBUP6.PSTEMPDB.SYS AD
Z67MX35A.OSPMX35A.PATCHIX PSDBCHK1.PSTEMPDB.SYS AD
Z35MX35A.OSPMX35A.PATCHIX PSDBCHK3.PSTEMPDB.SYS AD
Z36MX35A.OSPMX35A.PATCHIX PSDBCHK4.PSTEMPDB.SYS AD
Z75MX35A.OSPMX35A.PATCHIX PSDBCHK6.PSTEMPDB.SYS AD
Z78MX35A.OSPMX35A.PATCHIX PSUPSCHD.PSTEMPDB.SYS AD
P19MX35A.OSPMX35A.PATCHIX PSPSIDEL.PSTEMPDB.SYS AD
P12MX35A.OSPMX35A.PATCHIX PSUXFRNP.PRED.SYS RP
Z49MX35A.OSPMX35A.PATCHIX X017DSWS.PRED.SYS AD
Z38MX35A.OSPMX35A.PATCHIX X020DS22.PRED.SYS AD
Z39MX35A.OSPMX35A.PATCHIX X024DS2F.PRED.SYS AD
P02MX35A.OSPMX35A.PATCHIX PSCONFIG.PRED.SYS AD
P03MX35A.OSPMX35A.PATCHIX PSCONFGP.PRED.SYS AD
P07MX35A.OSPMX35A.PATCHIX MEMSCANP.PRED.SYS AD
P11MX35A.OSPMX35A.PATCHIX PSMDBSP.PRED.SYS AD
Z73MX35A.OSPMX35A.PATCHIX X015DSM1.PRED.SYS AD
Z83MX35A.OSPMX35A.PATCHIX X008DSM3.PRED.SYS AD
Z89MX35A.OSPMX35A.PATCHIX X003DSM4.PRED.SYS AD
Z54MX35A.OSPMX35A.PATCHIX X023ME00.PRED.SYS AD
Z46MX35A.OSPMX35A.PATCHIX X021DS5F.PRED.SYS AD
Z52MX35A.OSPMX35A.PATCHIX X019LU00.PRED.SYS AD
Z55MX35A.OSPMX35A.PATCHIX X022MU00.PRED.SYS AD
Z48MX35A.OSPMX35A.PATCHIX X025DS7S.PRED.SYS AD
Z53MX35A.OSPMX35A.PATCHIX X020MC00.PRED.SYS AD
Z61MX35A.OSPMX35A.PATCHIX X014SU00.PRED.SYS AD
Z84MX35A.OSPMX35A.PATCHIX FIXMEM.PRED.SYS AD
Z85MX35A.OSPMX35A.PATCHIX JFIXMEM.PRED.SYS AD
P22MX35A.OSPMX35A.PATCHIX MEMSCCOL.PRED.SYS AD
P23MX35A.OSPMX35A.PATCHIX PSCONCOL.PRED.SYS AD
P24MX35A.OSPMX35A.PATCHIX PSCFGCOL.PRED.SYS AD
P25MX35A.OSPMX35A.PATCHIX PSMDBCOL.PRED.SYS AD
Patch Package Size: 35376 sectors
General Release Text:
Known Conflicts
===============
Not applicable
Patch-to-Patch Dependencies
===========================
Requires Diagnostics version A.02.25 (ODIKXK2C or later)
(DUI Version A.02.25)
This version of diagnostics supports COLOSSUS.
Note that this is now a real dependency, so we do not need
the pre-colossus/post-colossus versions of MEMSCANP. This
patch must be installed on a system that has ODIKXK2C or
a later patch installed (As of the GR date of 12/16/2002
of OSPMX35A, the current GR ODI patch and the dependency
is ODILXA9A)
External Symptoms, Cause, Fix Description
=========================================
OSPMX35A contains Predictive version B.60.05
This patch (OSPMX35 A) is the 4th patch for Predictive
for MPE iX 6.0 It supercedes patches OSPKXT7B,OSPKXT7A,
and OSPKXP1A. The OSPKXT7 A patch was never released, but
the Quality Review copies of Powerpatch/Express I
had the "A" version of the patch.
This patch fixes 2 new problems:
8606-230470 - Predictive stops configuring devices if it
encounters a device with a path tha is > 16
characters long. This sometimes occurs because
a device is in the PPT (Physical Path Table)
with trailing blanks.
The fix for this is two-fold. First, remove
leading and trailing blanks from all string
fields. The string fields are the ldev,
pdev (path), and product identifier. The
second part of the fix is to NOT stop
configuring devices if 1 device has a path
that is too long. Just skip that device and
go on to the next device.
8606-178548 - Predictive on MPE iX with OSPKXT7B exhibits
an old problem:
If a 997 system has Colossus memory, MEMSCANP
aborts with the following stack trace:
+-------------------------------------+
| |
| H E W L E T T - P A C K A R D |
| |
| H P P R E D I C T I V E |
| |
| S U P P O R T |
| |
+-------------------------------------+
HP Predictive Version B.60.04
PSCONFIG Version B.00.10
Copyright (c) Hewlett-Packard Company, 1993-1994
All rights reserved
Please wait while Predictive checks your system's configuration.
STRING OVERFLOW (PASCERR 650)
ABORT: PSCONFIG.PRED.SYS
NM SYS a.00ab34a0 dbg_abort_trace+$24
NM PUB 260.00193a34 P__PASCFERROR+$3e0
NM PROG 3b5.0005027c retrieve_mem_config.retrieve_mem_detail.$4d54
Program terminated in an error state. (CIERR 976)
This occurs because the MEMSCAN program
submitted as P22KXT7B does NOT have the
Colossus changes as it should.
This patch includes the following rulesets:
DSM1 - X.00.15
These disks are configured as HP Product Number A3182A
DSP3107LS - [X.00.00]--Removed in [X.00.09]
Restored in [X.00.10]
ST31200N - [X.00.00]
These disks are configured as HP Product Number A3058A
DSP3107LSW - [X.00.00]--Removed in [X.00.09]
Restored in [X.00.10]
ST31200W - [X.00.00]
These disks are configured as HP Product Number A2958A
ST3610N - [X.00.02]
These disks are configured as HP Product Number A3191A
ST12400N - [X.00.02]
These disks are configured as HP Product Number C3550R/T
ST12400W - [X.00.02]
These disks are configured as HP Product Number A3349A
ST31230N - [X.00.02]
These disks are configured as HP Product Number A3350A
ST31230W - [X.00.02]
These disks are configured as HP Product Number A3304A
ST32550N - [X.00.02]
VP3215S - [X.00.03]
These disks are configured as HP Product Number A3351A
ST32550W - [X.00.02]
VP3215SW - [X.00.03]
These disks are configured as HP Product Number A3352A
ST15150N - [X.00.02]
These disks are configured as HP Product Number A3353A
ST15150W - [X.00.02]
These disks are configured identify as themselves:
ST19171N - [X.00.07]
ST19171W - [X.00.07]
ST32171N - [X.00.07]
ST32171W - [X.00.07]
ST34371N - [X.00.07]
ST34371W - [X.00.07]
XP32181S - [X.00.07]
XP32181WD - [X.00.07]
XP34361S - [X.00.07]
XP34361WD - [X.00.07]
ST32272N - [X.00.09]
ST32272WC - [X.00.09]
ST34572N - [X.00.09]
ST34572WC - [X.00.09]
XP34361W - [X.00.09]
ST34572W - [X.00.11]
DSM3 - X.00.08 Ruleset full. new disks are added to DSM4
ST32272WD - [X.00.04]
ST34572WD - [X.00.04]
ST34573N - [X.00.01]
ST34573W - [X.00.02]
ST34573WC - [X.00.01]
ST34573WD - [X.00.02]
ST39173N - [X.00.01]
ST39173W - [X.00.02]
ST39173WC - [X.00.01]
ST39173WD - [X.00.02]
ST118273N - [X.00.01]
ST118273W - [X.00.02]
ST118273WC - [X.00.01]
ST118273WD - [X.00.02]
DGHS04Y - [X.00.02]
DGHS09Y - [X.00.02]
ST39175WC - [X.00.03]
ST39175LW - [X.00.03]
ST39175LC - [X.00.05]
ST318203LC - [X.00.06]
ST318275WC - [X.00.03]
ST318275LW - [X.00.03]
ST318275LC - [X.00.06]
ST136475WC - [X.00.03]
ST136475LW - [X.00.03]
ST39102LC - [X.00.03]
ST136403LC - [X.00.07]
ST136403LW - [X.00.07]
ST318203LW - [X.00.07]
DSM4 - X.00.03 supports the following disks:
ST318404LC - [X.00.01]
ST318436LC - [X.00.01]
ST318436LW - [X.00.01]
ST336704LC - [X.00.01]
ST39103LC - [X.00.01]
ST39103LW - [X.00.01]
ST39204LC - [X.00.01]
ST39236LC - [X.00.01]
DMVS09D - [X.00.02]
DMVS18D - [X.00.02]
ST173404LC - [X.00.03]
ST173404LW - [X.00.03]
ST318405LC - [X.00.03]
ST318405LW - [X.00.03]
ST318406LC - [X.00.03]
ST318406LW - [X.00.03]
ST318451LC - [X.00.03]
ST318451LW - [X.00.03]
ST318452LC - [X.00.03]
ST318452LW - [X.00.03]
ST336705LC - [X.00.03]
ST336705LW - [X.00.03]
ST336706LC - [X.00.03]
ST336706LW - [X.00.03]
ST336752LC - [X.00.03]
ST336752LW - [X.00.03]
ST373405LC - [X.00.03]
ST39205LC - [X.00.03]
ST136475LC - [X.00.03]
DSWS - X.00.17
X.00.16 Changed the length portion of each
FNC entry to an even number, the
SCSI driver no longer supports
odd buffer length
X.00.17 Check the firmware revision of
C2490AM and WD disks and report
if firmware revision <5193.
DS2F - X.00.24
X.00.23 Change the 716 event from 1
ever to 2 in a day, Change
the 832 event from 6 in a week
to 6 in a day, Change the
845A event to 2 in a day from 1 ever.
X.00.24 increased threshold for C2201 disks so
they won't be reported
C22xx disks are no longer supported
DS22 - X.00.20
X.00.19 added autoconfig event 455
X.00.20 turned up threshold for C2200 disks so
they won't be reported
C22xx disks are no longer supported
DS5F - X.00.21
X.00.19 Added C2257.
X.00.20 Added C2257A.
X.00.21 DERR 157 on MPE now triggers event 826
as in UX (JAGac51286) and corrected
reference to ruleset version in >90 places
DS7S - X.00.25
X.00.23 Fixed Event 715 to check and report
correct nibble
X.00.24 Changed the length portion of each FNC
entry to an even number, the SCSI
driver no longer supports odd buffer length
X.00.25 Turned off reporting for all events by
increasing the thresholds. Disks C246*,
C247* covered by DS7S are no longer
supported. (JAGab78611)
LU00 - X.00.19
X.00.17 - Added PSCONFIG menu entry for extended scheduling
X.00.18 - Changes for MPE iX 7.0 Predictive
Added events 148,151-159
X.00.19 - Made documentation and message changes.
MC00 - X.00.20
X.00.16 corrected logic in Cheetah event 20,
Shogun event 45, and event 40.
X.00.17 consolidated Chimera and TNT Emeralds,
Added Nitro ($183).
X.00.18 added a number of hversions
jade ($184), kittyhawk (many), mohawk (many)
pcW ($5C6,$5BE,$5CC,$5D3),
X.00.19 added more hversions
pcW ($5DB,$5CB,$5D5,5D6,$5C4,$5C5,$5C9,5CA)
X.00.20 added Cantata hversions $5DF, $5E0
ME00 - X.00.23
X.00.21 Remove & from events 763 and 764
so that complete text would
show up(however) compressed.
X.00.22 Handle, but don't report, L2 cache errors on MPE
X.00.23 Fix up typo in 764 event
introduced with X.00.22
MU00 - X.00.22
X.00.20 - Added PSCONFIG menu entry for extended scheduling
X.00.21 - Added support for L2 Cache errors.
X.00.22 - Changed events for SHERLOCK-> MESA memory
logging changes
SU00 - X.00.14
X.00.13 - Changed 401 to 401A and 401B,
with 401A going to AS RL CN, every time,
and 401B going to AS RL CN RC,
with a threshold of 2 in a week,
and a supression of 3 weeks
X.00.14 - Removed references to obsolete patch
names (JAGab81943)
Changed threshold and suppression for
500B (JAGac40469)
For consistency, added /p/.
to end of text for events
The overall Predictive version of this patch is:
B.60.05
Includes the fixes that were supposed to be in OSPKXT7B:
1. COLOSSUS memory changes for JADE (997) systems
4701-425637
Fixes from the previous patch OSPKXP1 A are included in
OSPKXT7 A. For documentation purposes, here is a list of
the fixes from OSPKXP1 A:
The following problems are fixed in patch OSPKXP1 A:
1. Final Y2K fixes for MPE iX Onsite Predictive.
(SR 4701-415513)
2. A string overflow (PASCERR 650) occurs on EMERALD systems
(SR 4701-416024).
3. The following 5 rulesets have been updated since the
original MPE iX 6.0 submittal, and are included in this
patch (OSPKXP1 A):
DSM1 X.00.12 - Added handling of ASC $47 SCSI Interface
Interface Parity error.
DSWS X.00.17 - Check the firmware revision of C2490AM and
C2490WD disks And report if firmware revision
is less than 5193.
DSM3 X.00.03 -
DS22 X.00.20 -
DS2F X.00.24 -
Customer Environment Changes
============================
Not applicable
Hardware Dependencies
=====================
Not applicable
Software Product/Application Dependencies
=========================================
ODILXA9A is the current dependent ODI patch.
Product Version Information
===========================
See filename information for specific version changes for each module.
The overall Predictive version of this patch is:
B.60.05
Dump Analysis
=============
Not applicable
Product Number/Name:
HP50779 HP PREDICTIVE SUP
Product VUF: B.60.05
OS Release VUF: C.60.00
Fix Release Version: A
Supersedes:
( 0)OSPMX35 A
( 1) OSPKXT7 B
( 2) OSPKXT7 A
( 3) OSPKXP1 A
Criticality:
Non-critical
Distribution Recommendation:
For a FOS product and should be installed if appropiate.
(Special circumstances, the installer should read the text.
Update Required: Yes
Special Instructions:
NO SPECIAL INSTRUCTIONS PROVIDED FOR THIS PATCH
Installation Instructions:
Before installing this patch, please review all instructions and the
Hewlett-Packard SupportLine User Guide or Your Hewlett-Packard Support
Terms and Conditions for precautions, scope of license, restrictions,
and limitation of liability and warranties.
There is a document which gives a detailed descripton of all tasks
required prior to installing your patch. Request this document from
HPSL using e-mail (command: send mpeguide) or download it from the web
Unless there are special instructions, logon as MANAGER.SYS and run
UNPACKP to unpackage and restore all files before installing your patch.
Note! Please back up your system before you patch.
-----End of Document ID: OSPMX35A--------------------------------------------
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]