Neohapsis is currently accepting applications for employment. For more information, please visit our website www.neohapsis.com or email hr@neohapsis.com |
HP-UX series 700 10.X patch digest
From: IT Resource Center (support_feedback
us-support2-mail.external.hp.com)
Date: Sun Apr 06 2003 - 22:54:49 CDT
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
HP Support Information Digests
===============================================================================
o IT Resource Center World Wide Web Service
---------------------------------------------------
If you subscribed through the IT Resource Center and would
like to be REMOVED from this mailing list, access the
IT Resource Center on the World Wide Web at:
http://support.itrc.hp.com/
Login using your IT Resource Center User ID and Password.
Then select Support Information Digests (located under
Maintenance and Support). You may then unsubscribe from the
appropriate digest.
To download a patch referenced below, access the
IT Resource Center on the World Wide Web at:
http://support.itrc.hp.com/
Login using your IT Resource Center User ID and Password.
Then select Individual Patches (under Maintenance and Support)
to access the patch. You may also download a patch via anonymous
ftp(1) from ftp.itrc.hp.com.
===============================================================================
Digest Name: weekly HP-UX series 700 10.X patch digest
Created: Sun Apr 6 6:05:44 EDT 2003
Table of Contents:
Document ID Title
--------------- -----------
PHSS_28727 s700_800 10.X OV OB3.50 patch - CS packet
PHSS_28725 s700_800 10.X OV OB3.50 patch - CC packet
PHSS_28723 s700_800 10.20 OV OB4.10 patch - SAP packet
PHSS_28578 s700_800 10.X OV OB3.50 patch - SSEA packet
PHSS_27297 s700_800 10.20 OV ITO6.0X Solaris Agent Patch A.06.11
PHSS_28570 s700_800 10.X OV OB3.50 patch - CORE packet
PHSS_28887 s700 10.26 Multimedia patch
The documents are listed below.
-------------------------------------------------------------------------------
Document ID: PHSS_28727
Date Loaded: 20030404
Title: s700_800 10.X OV OB3.50 patch - CS packet
Patch Name: PHSS_28727
Patch Description: s700_800 10.X OV OB3.50 patch - CS packet
Creation Date: 03/03/27
Post Date: 03/04/04
Hardware Platforms - OS Releases:
s700: 10.00 10.01 10.10 10.20
s800: 10.00 10.01 10.10 10.20
Products:
OmniBackII A.03.50
Filesets:
OMNIBACK-II.OMNI-CS,A.03.50
Automatic Reboot?: No
Status: General Release
Critical: No
Path Name: /hp-ux_patches/s700_800/10.X/PHSS_28727
Symptoms:
PHSS_28727:
Id = HSLco39169 SR:H555009297
After aborting host backup the object post exec script
does not execute.
Id = HSLco39878 SR:H555009560
Backup run twice when daylight saving time is changed.
Id = HSLco40494 SR:H555009843
While backup with reconnect option is in progress and
BSM loses connection to monitor the message appears:
"[Warning] From: BSM
<host> "<device>" Time: <time>
[61:2013] Some of the backup devices are occupied.
Session is waiting for all the devices to get free.
[Major] From: BSM
<host> "<device>" Time: <time>
[61:3003] Lost connection to Monitor named "noname"
on host <host>.
Ipc subsystem reports: "IPC Read Error
System error: [232] Connection reset by peer"
Id = HSLco40537 SR:H555009863
When backing up very large SAP databases with SSEA
split mirror, backups can fail with error:
"BR280I Time stamp <time>
BR296I Split of mirror disks successful
BR274E File /<sapdata_path>/system.data1 not found"
PHSS_28021:
Id = HSLco35783 SR: H555008533
Informix backup hangs if a resource type is backed up
to a different device than the other resource types.
Id = HSLco36721 SR: H555008690
If a Manager-of-Managers Server is also a
MC/ServiceGuard virtual node, then the command:
"omnirpt -report list_sessions -timeframe
<start_hours_ago><hours_duration>
-multicell -no_multiple"
lists the matching sessions from this node twice.
Id = HSLco37099 SR: H555008780
Queries from client Cell Server in MoM environment
with CMMDB fail with:
"[12:1012] Cannot access the file."
Id = HSLco37193 SR: H555008807
When backing up SAP integration with EMC split mirror
functionality, not all the SAP files are backed up.
Id = HSLco37276 SR: H555008832
OmniBack internal database backup fails with an error:
"[Major] From: BSM
<computer> "<object>" Time: <time>
[61:3003] Lost connection to VBDA named <object>
on host <host>.
Ipc subsystem reports: "IPC Read Error
System error: [232] Connection reset by peer"
Id = HSLco37939 SR: H555008927
While configuring OmniBack II reports using GUI, only
datalists are listed (barlists are missing).
Id = HSLco37723 SR: H555008892
When performing omnimlist -catalog on media, the
program exits and debug.log contains this
Interprocess Communication error:
08/06/02 11:13:15 OMNIMLIST.1224.0
["/src/lib/ipc/ipc.c /main/r31_split/16":3434]
A.03.50 b216
[ipc_receiveDataEx] buffer 102400 bytes to
small to receive data 258487 bytes => ignored
PHSS_26889:
Id = HSLco35076 SR: H555008261
Backup fails with an error:
"Internal error. Allocation from library failed.
The Media Management daemon reports:
Internal error: DbaXXXX functions."
Id = HSLco35364 SR: H555008410
The earlier Patch PHSS_26348 introduced behavior
that can cause database integration
(for example Oracle or SAP) backups to fail.
With PHSS_26348 installed, OmniBack does not properly
lock the logical devices to prevent concurrent access
by multiple sessions. As a result, database integration
backups may fail instead of waiting for the device
to become free.
Id = HSLco35515 SR: H555008452
Backup Session Manager does not terminate after
the time specified in the SmDaIdleTimeout variable
when connection to Disk Agent and Media Agent is lost.
Id = JAGae27169 SR: 8606262839
Configuration report shows an incorrect list of
scheduled backups.
PHSS_26347:
Id = HSLco20414 SR: H555003134
Device maintenance from command line is not sufficient.
Id = HSLco31865 SR: H555006924
The message for the mount request is not in proper
format when forwarded to ITO.
Id = HSLco32789 SR: H555007191
If pre-exec script does not complete in
ScriptOutputTimeout time (default 15 minutes), Backup
Session Manager lopps and can not be aborted.
Id = JAGad90905 SR: 8606221771
Case sensitive search does not work.
Id = JAGae05208 SR: 8606236143
Not all session manager processes are correctly stopped
using csailover.ksh script.
Id = HSLco33360 SR: H555007428
Backup fails with error:
"[Major] From: BMA
<HOST> Time:<TIME>
[90:64] Can not unload exchanger medium
(Storage slot is occupied.)".
Id = JAGae14881 SR: 8606248483
Address of a Cell Console client is incorrectly
handled.
Id = HSLco34255 SR: H555007796
omnirpt failes after the installation of
PHSS_25002/25003.
PHSS_25002:
Id = HSLco24755 SR: B555011718
OmniBack II issues a mount request for tape during
the restore session.
Id = HSLco28232 SR: H555005922
Backup is waiting for all pre/post-exec scripts to
finish before proceeding.
Id = HSLco28279 SR: H555005975
Purge of filenames aborts daily.
Id = HSLco29098 SR: H555006248
Restore session fails with error:
"Can not load exchanger medium.".
Id = HSLco30814 SR: H555006710
Session ends as 'Failed' because OmniBack II tries
to back up non existent SAP redo logs.
Id = HSLco31142 SR: H555006771
Load balancing is not working properly.
Id = HSLco31295 SR: H555006799
OmniBack reports that medium copy session finished
successfully although it failed.
Id = HSLco31325 SR: H555006810
When OmniBack II Integration backup is aborted,
another complete sesson starts and finishes backup of
remaining database objects.
Id = JAGad86475 SR: 8606217323
Cell Request Server and session managers frequently
abort.
PHSS_24658:
Id = JAGad48558
OmniBack II creates duplicated tape labels.
Id = JAGad64442
OmniBack II internal database owner is not
properly set after configuring OmniBack II in
MC/ServiceGuard environment.
Id = NSMex03907
Browsing of a filesystem in Restore GUI sometimes
fails with an error:
"Cannot browse from root. Please specify
starting point.".
Id = NSMex04086
Session status is "Completed/Failures" although there
is no indication of errors.
Id = NSMex04149
If Cell Request Service (CRS) is restarted in cluster
aware mode, error:
"-2 starting omnidbutil -clear!"
occurs in cluster.log file.
Id = NSMex04164
Omnitrig fails with an error:
"Error parsing schedule purge_schedule.".
Id = NSMex04283
Adding OmniBack II licenses in MC/ServiceGuard
environment fails with an error:
"Cell Server host IP is not in IP range.".
Id = NSMex04287
Load balancing uses less devices than expected.
Id = NSMex04319
OmniBack II issues mount request, but it can not be
confirmed because the tape drive is busy.
Id = NSMex04311
Post-exec script specified for a virtual hostname does
not start if pre-exec script fails.
Id = NSMex04403
Tape import is reported successful although it is not.
Id = NSMex04540
Restore session fails with error:
"Can not load exchanger medium.".
PHSS_23470:
Id = JAGad36093
Session status indicates "Completed" although one of the
agents failed.
Id = NSMbb37729
Devbra reports:
"[90:11] Unrecognized option "/" => ignored".
Id = NSMex03425
Backup of SAP archive logs fails with:
"[Major] From: OB2BAR
<hostname> <ORASID> Time:<time>
Can not read BSM message (IPC Read Error
System error: [232] Connection reset by peer.)".
Id = NSMex03621
Restore does not work correctly after the mount
request confirmation.
Id = NSMex03701
OmniBack Session Report contains many
"[Warning] From: BSM
<hostname> <DBNAME> Time:<time>
Received connect from BAR Backup DA on host <host>
that is not specified in CLIENT statement in the
barlist."
warning messages.
Id = NSMex03711
Error:
"Hostname is not in IP range."
is reported after service guard fails over to a
secondary host.
Id = NSMex03739
Pre- and post-exec scripts return invalid exit status.
Id = NSMex03847
After upgrade to OmniBack II 3.50, backup to STK 9840
device fails with an error:
"Invalid physical device type => aborting."
Id = NSMex03894
Host backup fails if host has more than 600
mountpoints.
Id = NSMex03910
If Sybase backup fails before OB2BAR is started,
a Major message is reported in the session output,
but session status is "Completed".
Id = NSMex03917
Objects are lost from OmniBack II internal database
after the execution of "omnidbutil -cdbsync" command.
Id = NSMex03991
Full Oracle backup can be appended to a medium in a
pool with "append incremental only" property.
Id = NSMbb38972
MS Exchange 2000 scheduled backups do not start.
Id = NSMex03246
Backup Session Manager is sending wrong SNMP messages to
ITO Management server.
Id = NSMex04159
When restarting failed sessions multiple sessions are
created.
Id = NSMex04261
Import of session fails.
PHSS_23105:
Id = NSMex03757
Bad backup performance after upgrade from OmniBack II
2.55 or 3.00.
Id = NSMex03977
Execution of command
"omnirpt -report used_media -timeframe <t1> <t2>"
results in the following error message:
"DB[4] internal error [-16] record not connected
to set".
"DB[4] internal error [-16] record not connected
to set".
PHSS_22369:
Id = JAGad13634
Informix barlists are not converted into a OmniBack II
3.50 format after an upgrade from OmniBack II 2.55.
Id = JAGad17029
"List from media" ignores "See private objects" option.
Id = NSMex03356
Permanent license shows up as out of IP range.
Id = NSMex03365
Backup session is not logged in the database if file
pattern search is performed in parallel.
Id = NSMex03419
After importing a tape from 2.55 to 3.x cell some of
the files can not be restored.
Id = NSMex03466
After the upgrade from OmniBack II 3.00 to 3.50, a
warning
"Received connect from BAR backup DA on host
<hostname> that is not specified in CLIENT statement
in barlist."
appears on a client with multiple lan cards.
Id = NSMex03481
A backup of MC/SG can not be aborted after the switch.
Id = NSMex03491, JAGad28516
Directories are backed up even if excluded in host
backup.
Id = NSMex03493
Omnitrig does not pass debugging parameters to omnirpt.
Id = NSMex03583, NSMex03631
OmniBack II ignores the tape loaded after the mount
request for SCSI-II changer device.
Id = NSMex03638 SR: B554000768
Option "-change_objname" does not work properly.
Id = NSMex03501
List of media fails with an error:
"Medium details not available.
Medium owned by Cell Manager: <hostname>."
Id = NSMex03683
Copy session of write-protected tape is aborted and
cleaning tape is requested in the source tape drive.
Id = NSMex02584
Internal database server (RDS) abnormally ends due to
lack of memory.
Id = NSMex03702
Internal database server (RDS) abnormally ends during
a SAP restore.
Id = NSMex03289
Sessions are disappearing from OmniBack II database.
Id = NSMex03521
OmniBack II database gets corrupted.
Id = NSMex03737
Sessions are disappearing from OmniBack II database.
Id = NSMex03758, NSMex03759, NSMex03646
Execution of commands "omnidb -session <sess_id>" and
"omnirpt -report used_media -timeframe <n> <n>"
reports that the database is corrupt, but omnidbcheck
reports no problem.
Defect Description:
PHSS_28727:
Id = HSLco39169 SR:H555009297
Before executing the object post-exec script,
OmniBack II checks if session is aborting.
If it is, then script does not execute.
Resolution:
Global variable PostExecOnAbortHostBackup was added.
If this global variable is set to 1, the post-exec
script will execute even if the session is aborting.
Id = HSLco39878 SR:H555009560
The algorithm, that handles the daylight saving time
changes is incomplete.
Resolution:
The algorithm is changed for both time changes:
02h->03h and 03h->02h.
Id = HSLco40494 SR:H555009843
If BSM loses connection to monitor message appears.
The problem (reconnect) should only be reported
for agents (DA, MA...).
Resolution:
The function is modified to check if the connection
with the agent (DA, MA ...) is broken. If BSM loses
connection to monitor, no messages are displayed.
Part of SSPUX350_089.
Id = HSLco40537 SR:H555009863
In split mirror environment with very large SAP
databases, it can happen that the size of the message
buffer that OmniBack II uses is too small to fit in
for the complete list of SAP files to be backed up.
Resolution:
New environment variable is introduced: OB2IPCBUFSIZE.
In order to solve this problem, the buffer size can
be increased by setting the OB2IPCBUFSIZE environment
variable in the .omnirc file on CM, R1 and R2 hosts,
specifying the desired amount of memory to be used
for the buffer.
For determining buffer size please see the Resolution
of Id = HSLco37193 below.
Part of SSPUX350_088.
PHSS_28021:
Id = HSLco35783
With Informix integration backup, it is possible to
specify which resource type will be backed up by which
device. If most of the resource types are backed up to
n devices, but the L (Log) resource type is backed up
to a separate, additional device, and load balancing
is set to (max=n, min=n), then the session will hang
because it tries to lock n+1 devices for all the
resource type backups.
Resolution:
OmniBack now unlocks devices, if they were not used for
any backup for a certain amount of time. It also stops
media agents that have not had any backup agents
assigned to them for the timeout period. With both
changes (unlock device, stop media agent), it can start
new media agents, required by specific resource type
backup agents that have already contacted Backup Session
Manager.
Important note:
---------------
In order to get the session running, there are some
timeout parameters (global options) that have to be
properly set :
Global options
--------------
A - BackupDeviceIdle
B - SmPeerID
C - SmDaIdleTimeOut
D - SmMaIdleTimeOut
Conditions that have to be satisfied :
-----------
A<B
C<D
Example:
Default Suggested
value value
-----------------------------------
A 10min 4min
B 5min 5min
C 120min 120min
D 140min 140min
Explanation:
------------
[A<B]
After all BAR clients stop sending data to a device,
the BSM waits for either A or B timeout to happen for
the device. If the timeout A is reached, the backup
device will be stopped gracefully, if B timeout is
reached, it will be aborted. That's why it is important
that the condition A<B is fulfilled.
[C<D]
This is a general condition that must be met for all MA
and DA processes, and is stated in the global options
file.
It is important to keep the option BackupDeviceIdle
under 300 seconds (5 minutes). If 300 or higher, the
session behavior will be unpredictable (errors are
likely to appear).
Part of SSPUX350_087.
Id = HSLco36721
When running "omnirpt" command all the cell servers from
the "mom_info" and the local Cell Server are queried for
matching sessions. The virtual node and the local host
are actually the same machine, so the matching sessions
are listed twice.
Resolution:
The function gethostname() is not used any more to
determine if the inspected host is also the local host,
because in case of a Manager-of-Managers/ServiceGuard
environment it returns the physical node hostname and
not the virtual node hostname, making the virtual
hostname being seen as a non-local host. In this way
the virtual hostname is not queried for matching
sessions any more.
Id = HSLco37099
Format of messages is changed from buffer to pointer
but change is not implemented in all areas. Database
Session Manager gets message from MoM server in
improper format and closes the connection.
Resolution:
Size of message is dynamically changed, messages are
not send in fixed size anymore.
Id = HSLco37193
In split mirror environment with huge SAP databases
it can happen that the size of the message buffer
OmniBack II uses is too small to receive complete list
of SAP files to be backed up.
Resolution:
Setting the OB2IPCBUFSIZE environment variable in the
/opt/omni/.omnirc file on Cell Server, R1 and R2 hosts,
specifying the desired amount of memory to be used for
the buffer solves the described problem.
Please read the following instructions and make sure
that the patches listed in "Other Dependencies" section
(see below) are installed and the environment
variable is set on Cell Server, R1 and R2 systems before
running the backup!
How to determine the buffer size?
---------------------------------
N_obj: number of objects (files)
N_fs: number of file systems
N_lvmvg: number of volume groups
N_dg: number of disk groups
N_rdsk: number of rawdisks
Obj: Object Name
ObjBack: Object Backup Name
MntPathLen: Path name on backup (R2) host
(example: /var/opt/omni/tmp/App_host)
fsmnt: File System Mount Point
fsdev: File System Device File
(example: /dev/dsk/[c0t1d1,lvol1])
vg: Volume group
(ex: /dev/vg01)
dg: Disk group (VxVM) - dependence on mapfile
which is required for creating disk group
(example:/dev/vx/dsk/dg01)
rdsk: Raw disk file name
(example: /dev/rdsk/c1t1d1)
AvgLen_<xxx> average length of <xxx>
There are two different buffers used:
1. BSM <-> R1
2. R1 <-> R2
Calculating the BSM <-> R1 buffer size
--------------------------------------
MsgSize_BSM_R1 = N_obj * (AvgLen_Obj + 1 + MntPathLen)
Calculating the R1 <-> R2 buffer size
-------------------------------------
MsgSize_R1_R2 =
N_obj*(AvgLen_Obj+1+AvgLen_ObjBack) +
N_fs*(AvgLen_fsmnt*2 + MntPathLen + AvgLen_fsdev*2)+
N_lvmvg*(AvgLen_vg*2) + N_dg*(AvgLen_dg*2) +
N_rdsk*(AvgLen_rdsk*2)
Calculating the OB2IPCBUFSIZE value
-----------------------------------
OB2IPCBUFSIZE > max (MsgSize_BSM_R1, MsgSize_R1_R2)
RESTORE NOTE:
-------------
If restore is started using the sapbda utility,
the variable OB2IPCBUFSIZE must be exported to
environment prior to starting sapbda.
Known problems:
---------------
If the calculated variable OB2IPCBUFSIZE is correctly
set, but is still too small for the file list to fit
into the message buffer, the session will fail with
the following error seen in the report:
BR295I Splitting mirror disks...
BR280I Time stamp <time>
BR279E Return code from '/opt/omni/lbin/ob2smbsplit
/<sap_homedir_path>/.<filename>.lst': 2
BR299E Split/resynchronization of mirror disks failed
In this case the variable OB2IPCBUFSIZE must be
recalculated to appropriate value. See above how to
determine it.
Part of SSPUX350_080.
Id = HSLco37276
Last message from Disk Agent is sometimes lost. This
causes Disk Agent's status reported as "Failed".
Resolution:
New OmniBack II environment variable:
OB2VBDASLEEPBEFORECLOSE
is introduced.
Its default value is 0. Setting it to a positive
number, in /<OMNIBACK_HOME>/.omnirc file, it specifies
number of seconds to pass before Disk Agent completes
after sending the last block of data.
Sleep time insignificantly influences backup
performance.
Id = HSLco37939
Barlists are members of a group which is not displayed
under reporting group in GUI Reporting.
Resolution:
Barlists are moved to a group that is displayed in GUI.
Id = HSLco37723
Media handling results in IPC error when the buffer
size is increased and variable OB2IPCBUFSIZE is set as
described in above Resolution for problem HSLco37193.
Resolution:
Media Session Manager is rebuilt in order to properly
include the changes introduced with Resolution for
HSLco37193.
Part of SSPUX350_085.
PHSS_26889:
Id = HSLco35076
In case of Media Management Database corruption
backup can fail due to problems with the media
allocation.
Resolution:
Media allocation is improved.
Part of SSPUX350_066.
Id = HSLco35364
Two or more integration backup sessions using the same
device do not queue for backup, but they all try to use
this device at the same time. This results in media
agent failure. During integration backup device
should be locked for backup, but other sessions
can still use it.
Resolution:
Backup Session Manager correctly locks the device(s),
and other sessions wait in the queue for backup until
the device is free.
Part of SSPUX350_077.
Id = HSLco35515
In some cases because of incorrect agent exit code
Backup Session Manager does not terminate other agents
in correct order, which results in Backup Session
Manager hang.
Resolution:
The exit code is changed.
Part of SSPUX350_076.
Id = JAGae27169
Database session manager compares days, not taking
into account 15 minute units. Therefore report shows
some additional backups, which are scheduled past
the specified time frame.
Resolution:
Beside days Database Session Manager compares 15
minute units.
PHSS_26347:
Id = HSLco20414
Device enabling, disabling and status report cannot be
performed using OmniBack II command line.
Resolution:
New options "-disable_device", "-enable_device" and
"-device" are added to omnimm, omniupload and
omnidownload.
Part of SSPUX350_038.
Id = HSLco31865
The message is not properly filtered out.
Resolution:
The message is properly filtered before it is send
to ITO.
Id = HSLco32789
Improper implementation of object assigning to Media
Agent causes Backup Session Manager to loop forever.
Resolution:
Object assignment to Media Agent is corrected.
Id = JAGad90905
Flag for case sensitivity is not checked before
search session is executed.
Resolution:
Case sensitivity flag is always checked.
Id = JAGae05208
The regular expression that is parsed by the awk script
does not return the process ID (PID) which should be
killed.
Resolution:
Regular expression string in awk parse command is
changed.
Id = HSLco33360
Executing an "enter" operation for the slot being
used for backup results in backup failure.
Resolution:
New global option EnterEjectCheckLocking is
introduced. If this option is set, Media Management
operation checks if slot is locked and does not
use it.
Part of SSPUX350_072.
Id = JAGae14881
When a Cell Console client connects to the server,
user name, system name and domain are parsed
correctly, but IP address is not.
Resolution:
A new environment variable
'OB2CRSSTRICTHOSTNAMECHECKING'
is introduced. Setting its value to 1 is to enforce
the use of hostnames obtained from IP address.
Id = HSLco34255
Improperly built Database Session Manager causes
omnirpt to fail.
Resolution:
Properly built Database Session Manager in included
in patch.
PHSS_25002:
Id = HSLco24755
Rescan before backup option incorrectly deletes locked
slots information from OmniBack II database.
Resolution:
Locked slots are not updated during any rescan.
Id = HSLco28232
Backup session is in sleep mode during the
pre/post-exec scripts execution. This can cause
the session to last a long time.
Resolution:
New global option is introduced. Details:
name: PrePostExecOnEveryVolumeForHostBackup
format:
PrePostExecOnEveryVolumeForHostBackup=<0 or 1>
default: 0
If this option is set (=1), Backup Disk Agent (BDA)
will execute pre/post-exec scripts for every
volume of host object specified.
If this option is not set (=0), Backup Session
Manager (BSM) will execute pre-exec script
prior to starting first volume BDA and post-exec
script after last volume BDA. During the
execution of these scripts, the BSM will sleep.
Id = HSLco28279
In some special cases it is possible for purge of
filenames to fail with error written in the debug.log:
"DB[9] internal error [-16]
record not connected to set."
Resolution:
Purge is improved in order to correctly remove
such records.
Id = HSLco29098
After the mount request during restore from SCSI-II
library, OmniBack II tries to load "" medium into drive.
Resolution:
Restore session manager rechecks the configuration
after the mount request is confirmed.
Part of SSPUX350_048.
Id = HSLco30814
By design, OmniBack II ends session as 'Failed' if
there are no objects to back up.
Resolution:
Two new global variables have been introduced:
1) SessSucessfullWhenNoObjectsBackedUp=0
By setting this variable to 1 user can change the
Omniback II behavior in order to end the session
as successful when there are no objects backed up.
2) TreatScriptReturnAsNormal=<script return>
Setting this variable to a certain number instructs
OmniBack II to treat all the script returns equal
to the specified number as normal.
Part of SSPUX350_062.
Id = HSLco31142
There is no warning reported when one creates a datalist
or a barlist with load balancing enabled and minimum
number of devices greater than number of configured
logical devices.
Resolution:
Comparison of minimum and configured devices number
is implemented.
Id = HSLco31295
Media Session Manager does not send abort message to
Backup Media Agent started after Copy Media Agent
failed.
Resolution:
Media Session Manager properly handles abort message
from Copy Media Agent.
Id = HSLco31325
1) Error in Backup Session Manager.
When OmniBack II - Informix backup aborting,
another session starts and finishes the remaining
database spaces.
2) Informix wrong error handling.
Resolution:
1) Case BSM_STATE_ABORTING was changed in the order
that Backup Session Manager aborts session when
requested.
2) The way of translating OmniBack II errors into
Informix errors was changed with new condition
checking.
Part of SSPUX350_063.
Id = JAGad86475
Cell Request Server and session managers abort
because of an accept() command failure on some
HP-UX 11.x systems.
Resolution:
accept() command is re-executed in case of
ENOBUFS failure.
Part of SSPUX350_059.
PHSS_24658:
Id = JAGad48558
Initializition with "Autolabel" option creates
duplicated tape labels.
Resolution:
Medium initialization does not create duplicated tape
labels.
Id = JAGad64442
OmniBack II internal database ownership belongs to
primary node instead of floating hostname in
MC/ServiceGuard environment.
Resolution:
Database ownership is set to floating hostname.
Id = NSMex03907
The data backed up with an older version of OmniBack II
and option "-encrypt" can not be selected from
Restore GUI.
Resolution:
It is possible to select objects backed up with an
older version of OmniBack II in Restore GUI.
Id = NSMex04086
Message level of a resuming failure in XP environment
is set to "Normal" instead of "Major".
Resolution:
Message level is corrected.
Id = NSMex04149
Cell Request Service (CRS) executes "omnidbutil -clear"
and returns incorrect exit code.
Resolution:
Correct exit code is returned.
Id = NSMex04164
The parser incorrectly enumerates schedule types.
Resolution:
Schedule types are properly enumerated.
Part of SSPUX350_039.
Id = NSMex04283
OmniBack II is not able to list all interfaces in cells
with more than 20 LAN cards because the buffer is too
small.
Resolution:
Buffer for storing interfaces is increased.
Id = NSMex04287
OmniBack II does not lock all available devices.
Resolution:
Load balancing locks enough available devices to be used
for a session.
Id = NSMex04319
When there is no more media available for the running
session, mount request is issued. This mount request can
not be confirmed because the drive is locked by Backup
Session Manager.
Resolution:
Media Session Manager ignores Backup Session Manager
lock making the slot free for mount request
confirmation.
Id = NSMex04311
OmniBack II improperly recognizes post-exec script as a
start request if pre-exec script fails in cluster
environment.
Resolution:
OB2FORCEPOSTEXEC environment variable is added.
Setting its value to 1 in the .omnirc file causes
post-exec scripts to be started regardless of pre-exec
script exit code.
Part of SSPUX350_040.
Id = NSMex04403
Reporting functionality is missing in Media Session
Manager.
Resolution:
Reporting functionality is added to Media Session
Manager.
Part of SSPUX350_042.
Id = NSMex04540
After the mount request during restore from SCSI-II
library, Omniback tries to load "" medium into drive.
Resolution:
Restore session manager rechecks the configuration
after the mount request is confirmed.
PHSS_23470:
Id = JAGad36093
If one of the agent fails session status should
indicate "Completed/Errors" instead of "Completed".
Resolution:
Session status is correct.
Part of SSPUX350_027.
Id = NSMbb37729
Database Session Manager starts Device Browser with
incorrect options.
Resolution:
Structure containing Device Browser options is
initialized before it is filled with the parameters.
Id = NSMex03425
Backup of SAP archive logs fails if a backup request
for next archive log comes when Backup Session Manager
is already exiting.
Resolution:
Datalist entries for BAR session are removed.
Id = NSMex03621
When restoring the data from STK or GRAU library,
wrong medium is loaded into drive after the mount
request confirmation.
Resolution:
Mount request is properly handled.
Id = NSMex03701
Backing up Informix Parallel Server with many
datafiles where request is coming from the node
that is not specified in Informix backup
specification results in many warning messages reported
during the session.
Resolution:
New global option InformixparallelBackupIgnoreWarning
is added. Warnings are ignored if this option is set
to 1. Default value is 0.
Id = NSMex03711
Licensing is not working properly for systems with
more than 20 lan cards, due to an OmniBack limitation.
Resolution:
Number of lan cards on a single system can be up to 100.
Id = NSMex03739
Pre- and post-exec scripts return invalid exit status
because of timing problem.
Resolution:
Environment variable OB2EXECTIMEOUT is introduced.
Variable represents timeout (in seconds) after the end
of pre- and post-exec script. Default value is 0.
Recommended value is between 5 and 10 seconds.
Id = NSMex03847
New Media Class, 9840, is introduced with A.03.50
release. This caused that some of previously created
devices did not work with OmniBack II 3.50.
Resolution:
New utility, mchange, changes media class for a pool
and for all devices that use the particular pool.
Usage of mchange is:
mchange -version | -help
mchange -pool PoolName -newtype NewMediaClass
Id = NSMex03894
OmniBack II has a 600 mountpoints limitation. Host
backup fails if there are more than 600 mountpoints.
Resolution:
Number of mountpoints per host increased to 50000.
Id = NSMex03910
Major messages are not checked by Backup Session
Manager.
Resolution:
Backup Session Manager checks all messages.
Id = NSMex03917
If "omnidbutil -cdbsync" command is started in
Service Guard environment, some objects disappear
from OmniBack II internal database.
Resolution:
omnidbutil works properly in Service Guard
environment.
Part of SSPUX350_026.
Id = NSMex03991
Backup Session Manager incorrectly appends full
Oracle backups.
Resolution:
Backup Session Manager correctly checks properties
of pool.
Id = NSMbb38972
omnitrig does not support MS Exchange 2000 integration.
Resolution:
Scheduled MS Exchange 2000 backups are properly
started.
Part of SSPUX350_020.
Id = NSMex03246
Normal, Warning and Minor messages can be seen on ITO
Management server even though OVfilter is set up to
forward only Critical messages.
Resolution:
Messages are forwarded according to OVfilter setup.
Id = NSMex04159
When Backup Session Manager waits for the next client it
disables new client connections.
Resolution:
Proper previously failed session is restarted.
Id = NSMex04261
Import of integration session fails if the session is
spanned over two or more media.
Resolution:
Checking for object description is changed.
PHSS_23105:
Id = NSMex03757
Performance degrated by up to 50% after upgrade from
OmniBack II 2.55 or 3.00.
Resolution:
Redundant update of the objects removed.
Part of SSPUX350_023.
Id = NSMex03977
Listing of objects failed for the objects that have
been purged from the database, because there is no
link between objects and object versions.
Resolution:
Fix is implemented in libob2ecbd.sl.
PHSS_22369:
Id = JAGad13634
File /opt/omni/sbin/nb_informix is missing.
Resolution:
File /opt/omni/sbin/nb_informix is added to OMNI-CS
fileset.
Id = JAGad17029
Using "List from media" option in restore context
ignores "See private objects" option. Objects that are
backed up as "Private" are not listed.
Resolution:
Option parsing in restore context is improved.
Id = NSMex03356
If there are more than 100 network interfaces, ioctl()
call fails.
Resolution:
Buffer for SIOCGIFCONF is increased to support up to
1000 network interfaces.
Id = NSMex03365
When backup and file search sessions are started in
parallel, file search session locks the database.
Backup Session Manager tries to write backup
information into locked database. Since this action can
not be performed, the following messages are logged
in the rds.log:
"11740 [10-Apr-00 17:37:07] error status=5
11741 [10-Apr-00 17:37:07] GROUPLOCK ELEMENT:
userID=4, LockType=6, LockMode= *, RecSetType=10002,
dba=[0:0], odnum=1"
Resolution:
File pattern search is optimized to minimize the
possibilities of group locks.
Id = NSMex03419
OmniBack II 3.50 objects are case insensitive which is
not true for the SAP objects backed up with 2.55
version. Object tape format is changed with 3.50 as
well. These changes caused some SAP objects not to be
displayed in the Restore GUI after importing the tape
with SAP objects from 2.55 to 3.50.
Resolution:
Object names from tape are converted into OmniBack II
3.50 format after tape import from 2.55.
Id = NSMex03466
System name checking is not performed for systems with
multiple LAN cards. Backup Session Manager is checking
the system names only when looking for clusters.
Resolution:
System name checking is performed when looking for
clusters and systems with multiple LAN cards.
Id = NSMex03481
Aborting backup session is not possible because
Backup Session Manager incorrectly aborts Disk Agents
after the package switch.
Resolution:
Disk Agents are properly aborted.
Id = NSMex03491, JAGad28516
In host backup only mount point directories can be
excluded. If a directory is not a mount point then it
cannot be excluded from the backup.
Resolution:
Non-mountpoint directories can now be excluded.
Id = NSMex03493
Scheduled reports are not started with "-debug" option
although omnitrig is.
Resolution:
Command line option passing is implemented for omnirpt.
Id = NSMex03583, NSMex03631
Mount request is not properly implemented for SCSI-II
changer devices.
Resolution:
OmniBack II properly handles mount requests.
Id = NSMex03638
Option "-change_objname" is not meant to be a part of
OmniBack II A.03.50.
Resolution:
Option "-change_objname" is removed.
Id = NSMex03501
After upgrading OmniBack ServiceGuard package from
3.00 to 3.50, it is not possible to list media due to
incorrect ownership of medium.
Resolution:
Virtual hostname is used for medium ownership.
Part of SSPUX350_001.
Id = NSMex03683
Copy session is aborted when copying a write-protected
tape. When write-protected tape in the source drive is
checked, the cleaning tape for that drive is requested
and the following message appears:
"Cleaning tape requested by device <device_name>.
Please clean the drive.".
Resolution:
The cleanme signal is now processed correctly.
Part of SSPUX350_004.
Id = NSMex02584
Execution of command
"omnidb -filesystem <FS_Object> -file <File_Name>"
causes a memory leak in RDS (approx. 300 bytes). If the
command is started more than 100000 times, it can cause
RDS to die due to a lack of memory.
Resolution:
Fix is implemented in libob2ecdb.sl.
Part of SSPUX350_006.
Id = NSMex03702
RDS dies during a large SAP restore due to memory leak
described in NSMex02584.
Resolution:
Fix is implemented in libob2ecbd.sl.
Part of SSPUX350_006.
Id = NSMex03289
Media sync does not work properly when table of
exported/recycled media gets too big (>3000 media).
Some new sessions dissapear from database. No error is
reported.
Resolution:
Improved error handling logs this event in debug.log.
Part of SSPUX350_003.
Id = NSMex03521
Database stays in the hot mode after issuing an
"omnidbcheck" command. If a large amount of data is
written before OmniBack II daemons are stopped, it can
happen that hot files are not properly flushed. This
causes corruption of database.
Resolution:
omnidbcheck flushes hot files immediately after
database check.
Part of SSPUX350_003.
Id = NSMex03737
Media Session Manager is incorrectly initializing media
in ServiceGuard environment. Owner of medium is set to
hostname of the active node. This results in wrong
medium handling and objects from such medium are
removed from the OmniBack II database each time Media
Session Manager is started.
Resolution:
Initialization of media in ServiceGuard environment
is improved.
Before applying the fix for NSMex03737 please run
following commands:
omnidbutil -change_cell_name <hostname1>
and
omnidbutil -change_cell_name <hostname2>
where <hostname1> and <hostname2> are names of
ServiceGuard nodes.
Part of SSPUX350_010.
Id = NSMex03758, NSMex03759, NSMex03646
OmniBack II reports an error:
"Database is probably corrupt."
for backup sessions that span over two or more media
if one of them is already overwritten/exported because
then some of the objects are already removed from the
database.
Resolution:
Removed objects are skipped during the database queries.
Part of SSPUX350_010.
SR:
H555009863 H555009297 H555009560 H555009843 H555008927
H555008892 B554000611 B554000630 B554000712 B554000622
B554000550 B554000650 B554000623 B554000830 B554000831
B554000813 B554000418 B554000751 B554000761 B554000556
B554000487 B554000496 B554000776 B554000867 B554000597
B554000887 B554000888 B554000889 B555002886 H555008533
H555008832 H555004477 H555008807 H555008780 H555008690
H555008261 8606262839 H555008452 H555008410 B554000768
8606221771 8606248483 H555007191 H555003134 H555007796
H555007428 H555006924 8606236143 H555005975 H555005922
H555006248 B555011718 H555006771 H555006710 H555006799
H555006810 8606217323 H555005697 H555005402 H555005732
H555005680 H555005149 H555004871 H555005681 H555005583
H555005917 H555005973 8606179334 8606195237 H555004061
H555004026 H555004027 B555008272 H555005234 H555004452
H555003831 B554000869 H555005624 H555004364 H555004475
B554000372 B554000841 H555004021 8606166806 H555004350
8606159187 8606144294 8606147687
Patch Files:
/opt/omni/lbin/crs
/opt/omni/lbin/bsm
/opt/omni/lbin/dbsm
/opt/omni/lbin/msm
/opt/omni/lbin/mmd
/opt/omni/lbin/rsm
/opt/omni/lbin/psm
/opt/omni/lbin/dbbda
/opt/omni/sbin/omnitrig
/opt/omni/sbin/omnidbutil
/opt/omni/sbin/omnidbcheck
/opt/omni/sbin/nb_informix
/opt/omni/sbin/utilns/mchange
/opt/omni/sbin/install/omniforsg.ksh
/opt/omni/lib/libob2ecmn.sl
/opt/omni/lib/libob2ecdb.sl
/opt/omni/lib/libob2emmdb.sl
/opt/omni/lib/libob2eadm.sl
/opt/omni/newconfig/etc/opt/omni/options/global
/opt/omni/newconfig/etc/opt/omni/sg/csfailover.ksh
what(1) Output:
/opt/omni/lbin/crs:
[TZ=GMT0 /opt/omni/lbin/crs -version]
HP OpenView OmniBack II A.03.50: CRS, internal build
PHSS_28021/PHSS_28022, built on Wed Nov 20
13:11:01 2002
/opt/omni/lbin/bsm:
[TZ=GMT0 /opt/omni/lbin/bsm -version]
HP OpenView OmniBack II A.03.50: BSM, internal build
PHSS_28727/PHSS_28728, built on Wed Mar 26
11:11:09 2003
/opt/omni/lbin/dbsm:
[TZ=GMT0 /opt/omni/lbin/dbsm -version]
HP OpenView OmniBack II A.03.50: DBSM, internal buil
d PHSS_28021/PHSS_28022, built on Wed Nov 20
12:01:28 2002
/opt/omni/lbin/msm:
[TZ=GMT0 /opt/omni/lbin/msm -version]
HP OpenView OmniBack II A.03.50: MSM, internal build
PHSS_28021/PHSS_28022, built on Wed Nov 20
11:44:13 2002
/opt/omni/lbin/mmd:
[TZ=GMT0 /opt/omni/lbin/mmd -version]
HP OpenView OmniBack II A.03.50: MMD, internal build
PHSS_28021/PHSS_28022, built on Wed Nov 20
12:12:19 2002
/opt/omni/lbin/rsm:
[TZ=GMT0 /opt/omni/lbin/rsm -version]
HP OpenView OmniBack II A.03.50: RSM, internal build
PHSS_28021/PHSS_28022, built on Wed Nov 20
11:32:05 2002
/opt/omni/lbin/psm:
[TZ=GMT0 /opt/omni/lbin/psm -version]
HP OpenView OmniBack II A.03.50: PSM, internal build
PHSS_28021/PHSS_28022, built on Thu Nov 21
10:10:36 2002
/opt/omni/lbin/dbbda:
[TZ=GMT0 /opt/omni/lbin/dbbda -version]
HP OpenView OmniBack II A.03.50: DBBDA, internal bui
ld PHSS_28021/PHSS_28022, built on Thu Nov 2
1 09:47:19 2002
/opt/omni/sbin/omnitrig:
[TZ=GMT0 /opt/omni/sbin/omnitrig -version]
HP OpenView OmniBack II A.03.50: OMNITRIG, internal
build PHSS_28727/PHSS_28728, built on Tue Ma
r 25 10:08:42 2003
/opt/omni/sbin/omnidbutil:
[TZ=GMT0 /opt/omni/sbin/omnidbutil -version]
HP OpenView OmniBack II A.03.50: OMNIDBUTIL, interna
l build PHSS_28021/PHSS_28022, built on Thu
Nov 21 10:10:16 2002
/opt/omni/sbin/omnidbcheck:
[TZ=GMT0 /opt/omni/sbin/omnidbcheck -version]
HP OpenView OmniBack II A.03.50: OMNIDBCHECK, intern
al build PHSS_28021/PHSS_28022, built on Thu
Nov 21 10:10:26 2002
/opt/omni/sbin/nb_informix:
None
/opt/omni/sbin/utilns/mchange:
[TZ=GMT0 /opt/omni/sbin/utilns/mchange -version]
HP OpenView OmniBack II A.03.50: MCHANGE, internal b
uild PHSS_23470/PHSS_23471, built on Fri Mar
2 10:43:47 2001
/opt/omni/sbin/install/omniforsg.ksh:
None
/opt/omni/lib/libob2ecmn.sl:
None
/opt/omni/lib/libob2ecdb.sl:
None
/opt/omni/lib/libob2emmdb.sl:
None
/opt/omni/lib/libob2eadm.sl:
None
/opt/omni/newconfig/etc/opt/omni/options/global:
None
/opt/omni/newconfig/etc/opt/omni/sg/csfailover.ksh:
None
cksum(1) Output:
612034413 726899 /opt/omni/lbin/crs
1218843371 1182707 /opt/omni/lbin/bsm
1264986274 1239560 /opt/omni/lbin/dbsm
3952351799 694260 /opt/omni/lbin/msm
1499776461 530043 /opt/omni/lbin/mmd
3337452184 874939 /opt/omni/lbin/rsm
2483849962 435578 /opt/omni/lbin/psm
2181795817 365783 /opt/omni/lbin/dbbda
50284200 406791 /opt/omni/sbin/omnitrig
2522875831 697971 /opt/omni/sbin/omnidbutil
3950965868 472364 /opt/omni/sbin/omnidbcheck
2755861046 353611 /opt/omni/sbin/nb_informix
161435393 209564 /opt/omni/sbin/utilns/mchange
3275622251 5084 /opt/omni/sbin/install/omniforsg.ksh
114168317 812458 /opt/omni/lib/libob2ecmn.sl
1916829165 885460 /opt/omni/lib/libob2ecdb.sl
1619154841 651912 /opt/omni/lib/libob2emmdb.sl
3526392551 692720 /opt/omni/lib/libob2eadm.sl
2258981330 34415 /opt/omni/newconfig/etc/opt/omni/options/
global
1805127806 2350 /opt/omni/newconfig/etc/opt/omni/sg/
csfailover.ksh
Patch Conflicts: None
Patch Dependencies: None
Hardware Dependencies: None
Other Dependencies:
If any newer SSP for the Cell Server is installed
on your system, you must re-apply the SSP after
installing this Cell Server patch.
PHSS_28725:
Release Date: Available
Id = HSLco40537 SR:H555009863
Id = HSLco20414 SR:H555003134
Id = HSLco37193 SR:H555008807
PHSS_28725 is required for these defect fixes.
PHSS_28578:
Release Date: Available
Id = HSLco40537 SR:H555009863
PHSS_28578 is required for this defect fix.
PHSS_28570:
Release Date: Available
Id = HSLco40537 SR:H555009863
Id = HSLco37193 SR:H555008807
Bad catalog access messages are displayed without
PHSS_28570.
PHSS_28019:
Release Date: Available
Id = HSLco37193 SR:H555008807
PHSS_28019 is required for this defect fix.
PHSS_28017:
Release Date: Available
Id = HSLco40537 SR:H555009863
Id = HSLco30814 SR:H555006710
Id = HSLco37193 SR:H555008807
PHSS_28017 is required for these defect fixes.
PHSS_27589:
Release date: Available
Id = HSLco20414 SR:H555003134
Id = NSMex03638 SR:B554000768
PHSS_27589 is required for these defect fixes.
PHSS_25950:
Release date: Available
Id = HSLco31325 SR:H555006810
PHSS_25950 is required for this defect fix.
Supersedes:
PHSS_22369 PHSS_23105 PHSS_23470 PHSS_24658 PHSS_25002 PHSS_26347
PHSS_26889 PHSS_28021
Equivalent Patches:
PHSS_28728:
s700: 11.00 11.11 11.20
s800: 11.00 11.11 11.20
Patch Package Size: 11090 KBytes
Installation Instructions:
Please review all instructions and the Hewlett-Packard
SupportLine User Guide or your Hewlett-Packard support terms
and conditions for precautions, scope of license,
restrictions, and, limitation of liability and warranties,
before installing this patch.
------------------------------------------------------------
1. Back up your system before installing a patch.
2. Login as root.
3. Copy the patch to the /tmp directory.
4. Move to the /tmp directory and unshar the patch:
cd /tmp
sh PHSS_28727
5a. For a standalone system, run swinstall to install the
patch:
swinstall -x autoreboot=true -x match_target=true \
-s /tmp/PHSS_28727.depot
By default swinstall will archive the original software in
/var/adm/sw/patch/PHSS_28727. If you do not wish to retain a
copy of the original software, you can create an empty file
named /var/adm/sw/patch/PATCH_NOSAVE.
WARNING: If this file exists when a patch is installed, the
patch cannot be deinstalled. Please be careful
when using this feature.
It is recommended that you move the PHSS_28727.text file to
/var/adm/sw/patch for future reference.
To put this patch on a magnetic tape and install from the
tape drive, use the command:
dd if=/tmp/PHSS_28727.depot of=/dev/rmt/0m bs=2k
Special Installation Instructions:
PHSS_28727:
NOTE!
This Patch has to be installed on the Cell Manager host.
OmniBack II Services must be shut down before the patch is
installed. Use the following command to shut down the
services:
"/opt/omni/sbin/omnisv.sh stop".
After the installation is complete, restart OmniBack II
Services using "/opt/omni/sbin/omnisv.sh start".
Patch includes the following Site Specific Patches:
SSPUX350_001
SSPUX350_003
SSPUX350_004
SSPUX350_006
SSPUX350_010
SSPUX350_020
SSPUX350_023
SSPUX350_026
SSPUX350_027
SSPUX350_038
SSPUX350_039
SSPUX350_040
SSPUX350_042
SSPUX350_048
SSPUX350_059
SSPUX350_062
SSPUX350_063
SSPUX350_066
SSPUX350_072
SSPUX350_076
SSPUX350_077
SSPUX350_080
SSPUX350_085
SSPUX350_087
SSPUX350_088
SSPUX350_089
-----End of Document ID: PHSS_28727------------------------------------------
Document ID: PHSS_28725
Date Loaded: 20030404
Title: s700_800 10.X OV OB3.50 patch - CC packet
Patch Name: PHSS_28725
Patch Description: s700_800 10.X OV OB3.50 patch - CC packet
Creation Date: 03/03/24
Post Date: 03/04/04
Hardware Platforms - OS Releases:
s700: 10.00 10.01 10.10 10.20
s800: 10.00 10.01 10.10 10.20
Products:
OmniBackII A.03.50
Filesets:
OMNIBACK-II.OMNI-HPUX-P,A.03.50
OMNIBACK-II.OMNI-OTHUX-P,A.03.50
Automatic Reboot?: No
Status: General Release
Critical: No
Path Name: /hp-ux_patches/s700_800/10.X/PHSS_28725
Symptoms:
PHSS_28725:
Id = HSLco39486 SR:H555009404
GUI started with "xomni -restore -debug 1-99"
ends abnormally when Informix server option in
Restore context is selected.
Id = HSLco40532 SR:H555009862
When starting "omnir -mssql -barhost <host> -base
<basename>", restore ends with:
"Set '<basename>:0' not found. Most probably there
is a DNS configuration problem or one of the systems
is not in the same Cell Manager system."
Id = HSLco40537 SR:H555009863
When backing up very large SAP databases with SSEA
split mirror, backups can fail with error:
"BR280I Time stamp <time>
BR296I Split of mirror disks successful
BR274E File /<sapdata_path>/system.data1 not found"
PHSS_28222:
Id = HSLco37193 SR:H555008807
When backing up SAP integration with EMC split mirror
functionality, not all the SAP files are backed up.
Id = HSLco37723 SR: H555008892
If a Manager-of-Managers Server is also a
MC/ServiceGuard virtual node, then the command
"omnirpt -report list_sessions -timeframe
<start_hours_ago><hours_duration>
-multicell -no_multiple"
lists the matching sessions from this node twice.
PHSS_27595:
Id = HSLco31733 SR: H555006893
Additional dates added to periodic backup schedule
after 13 months.
Id = HSLco35611 SR: H555008476
Restore GUI can not handle two separate Oracle7
databases with the same SID. GUI does not display
all objects versions.
Id = HSLco35661 SR: H555008490
Filesystem restore summary displays incorrect version
of file selected for restore.
Id = HSLco36478 SR: H555008657
GUI ends abnormally when trying to perform Informix
restore.
Id = HSLco36904 SR: H555008730
xomnimm reports "Internal error" when trying to load
large media pool or device.
Id = JAGad97576 SR: 8606228519
Command Line (CLI) command omnimcopy does not provide
error codes.
Id = HSLco36916 SR: H555008732
HP-UX GUI corrupts barlists for SSEA backup created
using Windows GUI.
PHSS_25956:
Id = HSLco28793 SR: H555006144
Omnir command starts multiple Database Session
Managers.
Id = HSLco29971 SR: H555006524
Double-clicking an existing EMC datalist results in
the following error:
"Unknown object type encountered.".
Id = HSLco31433 SR: H555006834
omnir incorrectly parses "-srdf_smmf" option.
Id = HSLco31734 SR: H555006894
OmniBack does not select all the objects with the
same timestamp.
Id = JAGad57038 SR: 8606187829
"Omnidb -filesystem -detail" generates output in which
Object Name and Object Type files contents are
reversed.
PHSS_24660:
Id = NSMex03922
Listing of Oracle objects on GUI fails.
Id = NSMex03986
Omnir core dumps.
Id = NSMex04296
Backup scheduler shows incorrect dates.
Id = NSMex04323
Command "omnimm -enter [slot_range]" returns invalid
slot error.
Id = NSMex04347
Restore to a different host fails with an error:
"Can not stat script /usr/omni/bin/(null).".
Id = NSMbb39907
Any attempt to change object format in Oracle8 RMAN
script using OmniBack II GUI fails with the following
error:
"[12:1645] Format of RMAN channel names is not
correct.".
Id = HSLco20414
Device maintenance from command line is not sufficient.
Id = NSMex03989
Command
"omnirpt -report db_size -html -email <e-address>"
works improperly.
Id = NSMex04439
omnib command ignores "-encode" option.
Id = NSMbb38972
Exchange 2000 backup cannot be started from command
line.
PHSS_22850:
Id = JAGad30352
"EMC Support" tab is not available in
"Backup Specification - Options" GUI.
Id = JAGad35002
If database integration in a MC/ServiceGuard cluster is
backed up, the backup can report an error.
Id = NSMex03419
After importing a tape from 2.55 to 3.50 cell some of
the files can not be restored.
Id = NSMex03475
Restore GUI does not display SAP objects, if two
SAP instances with the same name are backed up on
different host.
Id = NSMex03505
a) When selecting restore of SAP object, message
"Cannot browse from root" appears.
b) When selecting restore from File System Restore
Dialog GUI might core dump.
Id = NSMex03658
Exit code of omniminit is incorrect.
Id = NSMex03833
The options under Edit button are not accessible even
if user has rights.
Id = JAGad29457
Ownership incorrectly displayed within restore GUI.
Id = JAGad33161
Datalists/barlists with EMC integration are incorrectly
created.
PHSS_22038:
Id = NSMex03503
Users with only "Start Backup" privilege can delete
datalists.
Id = NSMex03511
"Send external" method always executes external script
on Cell Manager system.
Defect Description:
PHSS_28725:
Id = HSLco39486
DbgPlain function is called with wrong string format.
Resolution:
String format for DbgPlain() is corrected.
Id = HSLco40532
The source of <basename> is not parsed.
Resolution:
The source of <basename> is parsed.
Id = HSLco40537
In split mirror environment with very large SAP
databases, it can happen that the size of the message
buffer that OmniBack II uses is too small to fit in
for the complete list of SAP files to be backed up.
Resolution:
New environment variable is introduced: OB2IPCBUFSIZE.
In order to solve this problem, the buffer size can
be increased by setting the OB2IPCBUFSIZE environment
variable in the .omnirc file on CM, R1 and R2 hosts,
specifying the desired amount of memory to be used
for the buffer.
For determining buffer size please see the Resolution
of Id = HSLco37193 below.
Part of SSPUX350_088.
PHSS_28222:
Id = HSLco37193 SR:H555008807
In split mirror environment with huge SAP databases
it can happen that the size of the message buffer
OmniBack II uses is too small to receive complete list
of SAP files to be backed up.
Resolution:
Setting the OB2IPCBUFSIZE environment variable in the
/opt/omni/.omnirc file on Cell Server, R1 and R2 hosts,
specifying the desired amount of memory to be used for
the buffer solves the described problem.
Please read the following instructions and make sure
that the patches listed in "Other Dependencies" section
(see below) are installed and the environment
variable is set on Cell Server, R1 and R2 systems before
running the backup!
How to determine the buffer size?
---------------------------------
N_obj: number of objects (files)
N_fs: number of file systems
N_lvmvg: number of volume groups
N_dg: number of disk groups
N_rdsk: number of rawdisks
Obj: Object Name
ObjBack: Object Backup Name
MntPathLen: Path name on backup (R2) host
(example: /var/opt/omni/tmp/App_host)
fsmnt: File System Mount Point
fsdev: File System Device File
(example: /dev/dsk/[c0t1d1,lvol1])
vg: Volume group
(ex: /dev/vg01)
dg: Disk group (VxVM) - dependence on mapfile
which is required for creating disk group
(example:/dev/vx/dsk/dg01)
rdsk: Raw disk file name
(example: /dev/rdsk/c1t1d1)
AvgLen_<xxx> average length of <xxx>
There are two different buffers used:
1. BSM <-> R1
2. R1 <-> R2
Calculating the BSM <-> R1 buffer size
--------------------------------------
MsgSize_BSM_R1 = N_obj * (AvgLen_Obj + 1 + MntPathLen)
Calculating the R1 <-> R2 buffer size
-------------------------------------
MsgSize_R1_R2 =
N_obj*(AvgLen_Obj+1+AvgLen_ObjBack) +
N_fs*(AvgLen_fsmnt*2 + MntPathLen + AvgLen_fsdev*2)+
N_lvmvg*(AvgLen_vg*2) + N_dg*(AvgLen_dg*2) +
N_rdsk*(AvgLen_rdsk*2)
Calculating the OB2IPCBUFSIZE value
-----------------------------------
OB2IPCBUFSIZE > max (MsgSize_BSM_R1, MsgSize_R1_R2)
RESTORE NOTE:
-------------
If restore is started using the sapbda utility,
the variable OB2IPCBUFSIZE must be exported to
environment prior to starting sapbda.
Known problems:
---------------
If the calculated variable OB2IPCBUFSIZE is correctly
set, but is still too small for the file list to fit
into the message buffer, the session will fail with
the following error seen in the report:
BR295I Splitting mirror disks...
BR280I Time stamp <time>
BR279E Return code from '/opt/omni/lbin/ob2smbsplit
/<sap_homedir_path>/.<filename>.lst': 2
BR299E Split/resynchronization of mirror disks failed
In this case the variable OB2IPCBUFSIZE must be
recalculated to appropriate value. See above how to
determine it.
Part of SSPUX350_080.
Id = HSLco37723
Media handling results in IPC error when the buffer
size is increased and variable OB2IPCBUFSIZE is set as
described in above Resolution for problem HSLco37193.
Resolution:
Media Session Manager is rebuilt in order to properly
include the changes introduced with Resolution for
HSLco37193.
Part of SSPUX350_085.
PHSS_27595:
Id = HSLco31733
In next year the same date is not the same day in
week. Scheduled dates after one year are just copied,
so backups are scheduled on wrong days.
Resolution:
Days are correctly moved to next year.
Id = HSLco35611
GUI does not check on which host Oracle7 database is
backed up and all backup versions are appended to
the first one found.
Resolution:
Host matching and object version adding to list is
improved.
Id = HSLco35661
Restore summary always displays the last version of
file selected for restore.
Resolution:
Restore summary displays file versions as they were
selected for restore.
Id = HSLco36478
Incorrect pointer handling causes GUI to end
ungracefully.
Resolution:
Pointers are properly handled.
Id = HSLco36904
A buffer sent to xomnimm after loading large media pool
or device is too big.
Resolution:
xomnimm reads the buffer size as specified in .omnirc
file with OB2IPCBUFSIZE variable.
Id = JAGad97576
Omniback II reports the same exit code regardless of
success or failure of the command omnimcopy.
Resolution:
When command omnimcopy fails Omniback II returns
exit code 3 = EX_ERR_INTERNAL.
Id = HSLco36916
Saving a SSEA barlist with HP-UX GUI corrupts barlist.
Resolution:
Saving a barlist with HP-UX GUI is not possible.
Part of SSPUX350_078.
PHSS_25956:
Id = HSLco28793
New Database Session Manager instance is started
every time when omnir is trying to retrieve object
information from the database.
Resolution:
Omnir reuses existing connections.
Part of SSPUX350_051.
Id = HSLco29971
Displaying EMC datalists is disabled.
Resolution:
Displaying EMC datalists is enabled.
Part of SSPUX350_055.
Id = HSLco31433
When "-rawdisk" option is combined with "-srdf",
"-smmf" or "-srdf_smmf", it is recognized only after
latter options have been checked.
Resolution:
Option "-rawdisk" has higher priority.
Id = HSLco31734
Restore GUI incorrectly interprets the data obtained
from Database Session Manager.
Resolution:
Restore GUI properly displays the latest versions of
restore objects.
Id = JAGad57038
The order of putting Object Type and Object FileName
into output files is wrong.
Resolution:
Object Type and Object FileName are displayed in
correct order.
PHSS_24660:
Id = NSMex03922
Incorrect memory usage causes GUI to core dump
whilst listing Oracle sessions.
Resolution:
Memory usage is improved.
Id = NSMex03986
The omnir command causes a memory fault and core dumps
if it is run with a long list of objects.
Resolution:
Omnir can handle long list of objects.
Id = NSMex04296
Backup scheduler loses months prior to January, 2002.
Resolution:
Scheduler optimization improved.
Id = NSMex04323
When executing "omnimm -enter [slot_range]" command
a "0" is appended to slot range. This causes invalid
slot error.
Resolution:
"omnimm -enter [slot_range]" command works properly.
Id = NSMex04347
Restore GUI improperly sends empty pre- and post-exec
options to Restore Session Manager.
Resolution:
Fix is implemented in Restore GUI.
Id = NSMbb39907
It is impossible to define the object format in an
Oracle8 RMAN script using the Omniback II GUI.
Resolution:
It is possible to change object format in Oracle8 RMAN
script using OmniBack II GUI.
Part of SSPUX350_031.
Id = HSLco20414
Device enabling, disabling and status report can not be
performed using OmniBack II command line.
Resolution:
New options "-disable_device", "-enable_device" and
"-device" are added to omnimm, omniupload and
omnidownload.
To disable/enable specific device and all other devices
with the same lockname, run:
omnimm -disable_device {device name}
omnimm -enable_device {device name}
To disable/enable all devices with the same lockname,
run:
omnimm -disable_lockname {lock name}
omnimm -enable_lockname {lock name}
To check if specific device is enabled/disabled, run:
omnidownload -device {device name}
Part of SSPUX350_038.
Id = NSMex03989
Command
"omnirpt -report db_size -html -email <e-address>"
returns HTML code instead of formatted report.
Resolution:
Missing header is added to HTML report.
Id = NSMex04439
omnib command ignores "-encode" option.
Resolution:
omnib command properly recognizes "-encode" option.
Id = NSMbb38972
Exchange 2000 backup cannot be started from command
line.
Resolution:
It is possible to start Exchange 2000 backup from
command line.
Part of SSPUX350_020.
PHSS_22850:
Id = JAGad30352
"EMC Support" tab is not available in
"Backup Specification - Options" GUI, unless the
cell_info entry for the Cell Manager has the
"-emc" option.
Resolution:
xomnibackup now correctly checks cell_info file
for "-emc" options.
Id = JAGad35002
a )Windows NT GUI supports cluster import which
creates additional attributes in the cell info
file to mark cluster nodes and virtual servers.
MC/SG clusters do not have such support yet.
b) Motif GUI does not have any way to import cluster
in the cell. Session Manager starts agent on certain
machine and expects that the connection will come
from that machine or a physical node on a cluster. If
additional attributes in the cell info are not set
then SM aborts the connection.
Resolution:
.util shell script has been enhanced to allow import
of the cluster using Windows GUI. The script handles
messages INFO_CLUS and INFO_CLUS1 which allow the
import to happen.
Id = NSMex03419
OmniBack II 3.50 objects are case insensitive which is
not true for the SAP objects backed up with 2.55
version. Object tape format is changed with 3.50 as
well. These changes caused some SAP objects not to be
displayed in the Restore GUI after importing the tape
with SAP objects from 2.55 to 3.50.
Resolution:
Names are tape format are converted into OmniBack II
3.50 format after tape import from 2.55.
Id = NSMex03475
Restore GUI does not display SAP objects, if two
SAP instances with the same name are backed up on
different host.
Resolution:
xomnirestore has been improved to show all object.
Id = NSMex03505
a) When selecting restore of SAP object, message
"Cannot browse from root" appears.
b) Two different structures with the same name
were defined.
Resolution:
xomnirestore has been improved.
Id = NSMex03658
Exit code 0 is returned when the medium initialization
fails with error:
"This medium can be initialized only with force option
specified."
Resolution:
Exit code of omniminit for failed operation is
redefined.
Id = NSMex03833
User rights are not properly interpreted.
Resolution:
User rights permissions has been modified.
Id = JAGad29457
xomnirestore shows user name and group name for backed
up objects. If users on different clients have
different UID and GID wrong user will be shown in
version browser.
Resolution:
New option GUIShowUID has to be set in file:
/etc/opt/omni/options/global on Cell Manager host.
GUIShowUID=<number>
where <number> means:
- 0, GUI converts UIDs and GIDs to strings
- 1, only UIDs and GIDs numbers will be showen
Part of SSPUX350_013.
Id = JAGad33161
Options for EMC integration are incorrectly saved when
datalist/barlist is created with Motif GUI.
Resolution:
EMC type resolving has been improved.
Part of SSPUX350_013.
PHSS_22038:
Id = NSMex03503
User rights are not properly checked.
Resolution:
User rights checking is properly improved.
Id = NSMex03511
Execution of external script can not be prevented.
Resolution:
Omnirpt is changed so that the execution of "Send
external" method can be controlled by adding a line
ExternalScriptMode=<number>
in Global Options file, where <number> means:
- 0, no checking is performed
- 1, script can be executed only in bin directory
- 2, executing of external scripts is not allowed.
SR:
H555009862 H555009592 H555009404 H555009863 H555008927
H555008892 H555008803 H555008807 H555008476 H555008657
H555006893 H555008730 B554000640 B554000632 H555008732
H555008490 8606228519 H555006524 H555006894 H555006834
H555006144 8606187829 H555004942 H555003134 8606179663
H555005709 H555005547 H555005845 H555004369 H555004246
H555004381 8606160131 8606161034 8606163859 B554000788
8606165711 B554000550 H555003728 B554000606 B554000634
Patch Files:
/opt/omni/databases/vendor/cc/hp/s800/hp-ux-1020/A.03.50/
packet.Z
/opt/omni/databases/vendor/cc/hp/s800/hp-ux-10/A.03.50/
packet.Z
/opt/omni/databases/vendor/cc/hp/s800/hp-ux-11/A.03.50/
packet.Z
/opt/omni/databases/vendor/cc/ncr/i386/mp-ras/A.03.50/
packet.Z
/opt/omni/databases/vendor/cc/dec/alpha/osf1-4/A.03.50/
packet.Z
/opt/omni/databases/vendor/cc/gpl/i386/linux/A.03.50/
packet.Z
/opt/omni/databases/vendor/cc/ibm/rs6000/aix-42/A.03.50/
packet.Z
/opt/omni/databases/vendor/cc/sco/i386/sco_sv/A.03.50/
packet.Z
/opt/omni/databases/vendor/cc/sco/i386/unixware/A.03.50/
packet.Z
/opt/omni/databases/vendor/cc/sequent/i386/dynix/A.03.50/
packet.Z
/opt/omni/databases/vendor/cc/sgi/mips/irix/A.03.50/packet.Z
/opt/omni/databases/vendor/cc/sgi/mips/irix-62/A.03.50/
packet.Z
/opt/omni/databases/vendor/cc/siemens/r400/sinix/A.03.50/
packet.Z
/opt/omni/databases/vendor/cc/sun/sparc/solaris/A.03.50/
packet.Z
/opt/omni/databases/vendor/cc/sun/sparc/solaris-26/A.03.50/
packet.Z
/opt/omni/databases/vendor/cc/sun/sparc/sunos/A.03.50/
packet.Z
what(1) Output:
/opt/omni/databases/vendor/cc/hp/s800/hp-ux-1020/A.03.50/
packet.Z:
None
/opt/omni/databases/vendor/cc/hp/s800/hp-ux-10/A.03.50/
packet.Z:
None
/opt/omni/databases/vendor/cc/hp/s800/hp-ux-11/A.03.50/
packet.Z:
None
/opt/omni/databases/vendor/cc/ncr/i386/mp-ras/A.03.50/
packet.Z:
None
/opt/omni/databases/vendor/cc/dec/alpha/osf1-4/A.03.50/
packet.Z:
None
/opt/omni/databases/vendor/cc/gpl/i386/linux/A.03.50/
packet.Z:
None
/opt/omni/databases/vendor/cc/ibm/rs6000/aix-42/A.03.50/
packet.Z:
None
/opt/omni/databases/vendor/cc/sco/i386/sco_sv/A.03.50/
packet.Z:
None
/opt/omni/databases/vendor/cc/sco/i386/unixware/A.03.50/
packet.Z:
None
/opt/omni/databases/vendor/cc/sequent/i386/dynix/A.03.50/
packet.Z:
None
/opt/omni/databases/vendor/cc/sgi/mips/irix/A.03.50/
packet.Z:
None
/opt/omni/databases/vendor/cc/sgi/mips/irix-62/A.03.50/
packet.Z:
None
/opt/omni/databases/vendor/cc/siemens/r400/sinix/A.03.50/
packet.Z:
None
/opt/omni/databases/vendor/cc/sun/sparc/solaris/A.03.50/
packet.Z:
None
/opt/omni/databases/vendor/cc/sun/sparc/solaris-26/A.03.50/
packet.Z:
None
/opt/omni/databases/vendor/cc/sun/sparc/sunos/A.03.50/
packet.Z:
None
cksum(1) Output:
1535824785 11152455 /opt/omni/databases/vendor/cc/hp/s800/
hp-ux-1020/A.03.50/packet.Z
903497905 11208336 /opt/omni/databases/vendor/cc/hp/s800/
hp-ux-10/A.03.50/packet.Z
2271713999 11147314 /opt/omni/databases/vendor/cc/hp/s800/
hp-ux-11/A.03.50/packet.Z
2055934160 4172467 /opt/omni/databases/vendor/cc/ncr/i386/
mp-ras/A.03.50/packet.Z
3047406478 4949573 /opt/omni/databases/vendor/cc/dec/alpha/
osf1-4/A.03.50/packet.Z
2143153229 8627390 /opt/omni/databases/vendor/cc/gpl/i386/
linux/A.03.50/packet.Z
723479229 4217255 /opt/omni/databases/vendor/cc/ibm/rs6000/
aix-42/A.03.50/packet.Z
3759737747 4028813 /opt/omni/databases/vendor/cc/sco/i386/
sco_sv/A.03.50/packet.Z
3343189653 3941384 /opt/omni/databases/vendor/cc/sco/i386/
unixware/A.03.50/packet.Z
3819542767 4126913 /opt/omni/databases/vendor/cc/sequent/
i386/dynix/A.03.50/packet.Z
1089219669 5022182 /opt/omni/databases/vendor/cc/sgi/mips/
irix/A.03.50/packet.Z
2371282407 5922365 /opt/omni/databases/vendor/cc/sgi/mips/
irix-62/A.03.50/packet.Z
3937653808 4878331 /opt/omni/databases/vendor/cc/siemens/
r400/sinix/A.03.50/packet.Z
1711704483 4578857 /opt/omni/databases/vendor/cc/sun/sparc/
solaris/A.03.50/packet.Z
3292819385 4661017 /opt/omni/databases/vendor/cc/sun/sparc/
solaris-26/A.03.50/packet.Z
2190727103 6980139 /opt/omni/databases/vendor/cc/sun/sparc/
sunos/A.03.50/packet.Z
Patch Conflicts: None
Patch Dependencies: None
Hardware Dependencies: None
Other Dependencies:
If any newer SSP for the Cell Console is installed
on your system, you must re-apply the SSP after
installing this Cell Console patch.
PHSS_28727:
Release date: Available
Id = HSLco40537 SR:H555009863
Id = HSLco37193 SR:H555008807
PHSS_28727 is required for these defect fixes.
PHSS_28578:
Release date: Available
Id = HSLco40537 SR:H555009863
PHSS_28578 is required for this defect fix.
PHSS_28570:
Release date: Available
Id = HSLco40537 SR:H555009863
Id = HSLco37193 SR:H555008807
Bad catalog access messages are displayed without
PHSS_28570.
PHSS_28019:
Release Date: Available
Id = HSLco37193 SR:H555008807
PHSS_28019 is required for this defect fix.
PHSS_28017:
Release Date: Available
Id = HSLco40537 SR:H555009863
Id = HSLco37193 SR:H555008807
PHSS_28017 is required for these defect fixes.
Supersedes:
PHSS_22038 PHSS_22850 PHSS_24660 PHSS_25956 PHSS_27595 PHSS_28222
Equivalent Patches:
PHSS_28726:
s700: 11.00 11.11 11.20
s800: 11.00 11.11 11.20
Patch Package Size: 97360 KBytes
Installation Instructions:
Please review all instructions and the Hewlett-Packard
SupportLine User Guide or your Hewlett-Packard support terms
and conditions for precautions, scope of license,
restrictions, and, limitation of liability and warranties,
before installing this patch.
------------------------------------------------------------
1. Back up your system before installing a patch.
2. Login as root.
3. Copy the patch to the /tmp directory.
4. Move to the /tmp directory and unshar the patch:
cd /tmp
sh PHSS_28725
5a. For a standalone system, run swinstall to install the
patch:
swinstall -x autoreboot=true -x match_target=true \
-s /tmp/PHSS_28725.depot
By default swinstall will archive the original software in
/var/adm/sw/patch/PHSS_28725. If you do not wish to retain a
copy of the original software, you can create an empty file
named /var/adm/sw/patch/PATCH_NOSAVE.
WARNING: If this file exists when a patch is installed, the
patch cannot be deinstalled. Please be careful
when using this feature.
It is recommended that you move the PHSS_28725.text file to
/var/adm/sw/patch for future reference.
To put this patch on a magnetic tape and install from the
tape drive, use the command:
dd if=/tmp/PHSS_28725.depot of=/dev/rmt/0m bs=2k
Special Installation Instructions:
PHSS_28725:
NOTE!
This Patch has to be installed on the Installation
Server host.
The User Interface must be redistributed to the client
system(s) after the installation of the patch in order
to get the fixes into effect.
For distribution of the User Interface, refer to the
OmniBackII Installation guide.
Patch includes the following Site Specific Patches:
SSPUX350_013
SSPUX350_020
SSPUX350_031
SSPUX350_038
SSPUX350_051
SSPUX350_055
SSPUX350_078
SSPUX350_080
SSPUX350_085
SSPUX350_088
-----End of Document ID: PHSS_28725------------------------------------------
Document ID: PHSS_28723
Date Loaded: 20030404
Title: s700_800 10.20 OV OB4.10 patch - SAP packet
Patch Name: PHSS_28723
Patch Description: s700_800 10.20 OV OB4.10 patch - SAP packet
Creation Date: 03/03/20
Post Date: 03/04/04
Hardware Platforms - OS Releases:
s700: 10.20
s800: 10.20
Products:
OmniBackII A.04.10
Filesets:
OMNIBACK-II.OMNI-SAP-P,A.04.10
Automatic Reboot?: No
Status: General Release
Critical: No
Path Name: /hp-ux_patches/s700_800/10.X/PHSS_28723
Symptoms:
PHSS_28723:
Id = HSLco39882 SR: H555009563
Data Protector SAP R/3 integration does not work on
SAP R/3 system with Oracle 9i.
Id = HSLco40709 SR: H555009941
Restore of sap tablespace on raw disk bigger than the
one backed up falls into loop. Restore agent is then
aborted due to inactivity by session manager.
Id = HSLco40764 SR: H555009971
During a SAP backup session, debug.log file is being
filled with "Unknown state" messages.
PHSS_28343:
Id = HSLco36193 SR: H555008621
Errors are reported in debug.log for files of size 0 and
for missing function entry statements.
Id = HSLco36404 SR: H555008642
SAP BR tools 6.10 reports:
"BR247E No Backup utility ID or ID longer than 16
characters".
Id = HSLco37193 SR: H555008807
When backing up SAP integration with EMC split mirror
functionality, not all the SAP files are backed up.
Id = HSLco37210 SR: H555008812
During raw device SAP restore following error is
reported:
"|Minor| From: OB2BAR_SAPREST
<host> "" Time:<time>
Error: Cannot open object <raw disk path>
|20| Not a directory)."
Id = HSLco37773 SR: H555008906
During some backint queries following error is reported:
"|Critical| From: OB2BAR
<host> "" Time:<time>
Failed to allocate memory.
System error: |12| Not enough space"
Id = HSLco37783 SR: H555008908
When OmniBack II tries to backup nonexistent SAP redo
logs, session ends as failed.
Id = HSLco39552 SR: H555009439
SAP backup on Linux, reports the following error:
"Cannot get information on file
'/sapmnt/SID/exe/brarchive ...' Error: 22."
PHSS_27452:
Id = HSLco35628 SR: H555008480
Raw partition backup is not restored even though
OmniBack II states that restore session is completed
successfully.
Id = HSLco35646 SR: H555008483
Aborting SAP backup session results in executing new
session.
Id = JAGae25124 SR: 8606260802
Session log files contains improper information when
SAP backup fails.
Id = HSLco35966 SR: H555008565
"util_sap -APP" displays connection strings.
PHSS_26887:
Id = HSLco33261 SR: H555007380
SAP integration on UNIX clients automatically passes
"-u" option.
Id = HSLco33795 SR: H555007605
OmniBack II SAP integration is not supported on
Compaq Tru64 operating system.
Defect Description:
PHSS_28723:
Id = HSLco39882
Oracle Server Manager (svrmgrl) is obsoleted with
Oracle 9i. sqlplus needs to be used instead.
Resolution:
Data Protector SAP R/3 integration works on SAP R/3
system with Oracle 9i.
Part of SSPUX410_067.
Id = HSLco40709
Size of data to be restored is mistakenly overwritten
by disk size checking function.
Resolution:
Disk size checking function is changed in a manner that
it properly calculates destination directory properties.
Part of SSPUX410_064.
Id = HSLco40764
All information messages in switch.log, except #SUCCESS
and #ERROR, are being treated as serious error.
Resolution:
Status of information messages is lowered from "error"
to normal.
PHSS_28343:
Id = HSLco36193
CheckFile checks marked error if parameter is null.
Debugs are initialized after function entry is marked.
Resolution:
Error messages are not written to the debug.log file.
Id = HSLco36404
Set ID number searching is not strict enough and gets
confused by new SAP BR tools format.
Resolution:
Stricter checking is applied to see if it really is
backint ID.
Part of SSPUX410_036.
Id = HSLco37193
In split mirror environment with huge SAP databases
it can happen that the size of the message buffer
OmniBack II uses is too small to receive complete list
of SAP files to be backed up.
Resolution:
Setting the OB2IPCBUFSIZE environment variable in the
/opt/omni/.omnirc file on Cell Server, R1 and R2 hosts,
specifying the desired amount of memory to be used for
the buffer solves the described problem.
Please read the following instructions and make sure
that the patches listed in "Other Dependencies" section
(see below) are installed and the environment
variable is set on Cell Server, R1 and R2 systems before
running the backup!
How to determine the buffer size?
---------------------------------
N_obj: number of objects (files)
N_fs: number of file systems
N_lvmvg: number of volume groups
N_dg: number of disk groups
N_rdsk: number of rawdisks
Obj: Object Name
ObjBack: Object Backup Name
MntPathLen: Path name on backup (R2) host
(example: /var/opt/omni/tmp/App_host)
fsmnt: File System Mount Point
fsdev: File System Device File
(example: /dev/dsk/|c0t1d1,lvol1|)
vg: Volume group
(ex: /dev/vg01)
dg: Disk group (VxVM) - dependence on mapfile
which is required for creating disk group
(example:/dev/vx/dsk/dg01)
rdsk: Raw disk file name
(example: /dev/rdsk/c1t1d1)
AvgLen_<xxx> average length of <xxx>
There are two different buffers used:
1. BSM <-> R1
2. R1 <-> R2
Calculating the BSM <-> R1 buffer size
--------------------------------------
MsgSize_BSM_R1 = N_obj * (AvgLen_Obj + 1 + MntPathLen)
Calculating the R1 <-> R2 buffer size
-------------------------------------
MsgSize_R1_R2 =
N_obj*(AvgLen_Obj+1+AvgLen_ObjBack) +
N_fs*(AvgLen_fsmnt*2 + MntPathLen + AvgLen_fsdev*2)+
N_lvmvg*(AvgLen_vg*2) + N_dg*(AvgLen_dg*2) +
N_rdsk*(AvgLen_rdsk*2)
Calculating the OB2IPCBUFSIZE value
-----------------------------------
OB2IPCBUFSIZE > max (MsgSize_BSM_R1, MsgSize_R1_R2)
RESTORE NOTE:
-------------
If restore is started using the sapbda utility,
the variable OB2IPCBUFSIZE must be exported to
environment prior to starting sapbda.
Known problems:
---------------
If the calculated variable OB2IPCBUFSIZE is correctly
set, but is still too small for the file list to fit
into the message buffer, the session will fail with
the following error seen in the report:
BR295I Splitting mirror disks...
BR280I Time stamp <time>
BR279E Return code from '/opt/omni/lbin/ob2smbsplit
/<sap_homedir_path>/.<filename>.lst': 2
BR299E Split/resynchronization of mirror disks failed
In this case the variable OB2IPCBUFSIZE must be
recalculated to appropriate value. See above how to
determine it.
Part of SSPUX410_033.
Id = HSLco37210
OmniBack II ignores the following caution in the SAP
specification:
"Caution:By restoring raw partition to a different
one, the <dest_dir> means directly the new raw
partition, not the directory containing the special
file."
Resolution:
Destination directory forming procedure is changed.
Id = HSLco37773
Some parts of structures for query are allocated but
not released.
Resolution:
All allocated structures are released.
Id = HSLco37783
By design, whenever there are no objects backed up,
OmniBack II ends session as failed.
Resolution:
Two new global variables have been introduced:
a) SessSucessfullWhenNoObjectsBackedUp=0
By setting this variable to 1 user can change the
OmniBack II behavior in order to end the session as
successful when there are no objects backed up.
b) TreatScriptReturnAsNormal=<script return>
By setting this variable to a certain number instructs
OmniBack II to treat all the script returns equal to
the specified number as normal.
Id = HSLco39552
'brbackup' and 'brarchive' are called with wrong
parameters.
Resolution:
Parameters for 'brarchive' and 'brbackup' calls are
corrected.
Part of SSPUX410_050.
PHSS_27452:
Id = HSLco35628
Incorrect function is used for raw partition restore.
Resolution:
Raw partition restore uses proper function.
Part of SSPUX410_027.
Id = HSLco35646
Abort mechanism is implemented incorrectly.
Resolution:
Sapback aborts all the objects upon abort request from
OmniBack II user.
Id = JAGae25124
Session log files contains improper information when
SAP backup fails.
Resolution:
Log files contain proper information.
Part of SSPUX410_023.
Id = HSLco35966
Connection string in printed in plain text format.
Resolution:
Connection string is encrypted before it is passed
to GUI.
Part of SSPUX410_025.
PHSS_26887:
Id = HSLco33261
brbackup/brarchive is always started with "-u" option
which displays logon information.
Resolution:
brbackup/brarchive options are passed in a file.
Part of SSPUX410_014.
Id = HSLco33795 SR: H555007605
OmniBack II SAP integration is not supported on
Compaq Tru64 operating system.
Resolution:
OmniBack II SAP integration is supported on
Compaq Tru64 operating system.
SR:
H555009971 H555009941 H555009563 H555008908 H555009439
8606207021 H555008621 H555008812 H555008642 H555008643
H555008906 H555008807 H555008480 8606244527 8606260802
H555008483 H555008565 H555007605 H555007380
Patch Files:
/opt/omni/databases/vendor/sap/gpl/i386/linux-60/A.04.10/
packet.Z
/opt/omni/databases/vendor/sap/hp/s800/hp-ux-1020/A.04.10/
packet.Z
/opt/omni/databases/vendor/sap/hp/s800/hp-ux-11/A.04.10/
packet.Z
/opt/omni/databases/vendor/sap/ibm/rs6000/aix-42/A.04.10/
packet.Z
/opt/omni/databases/vendor/sap/sun/sparc/solaris-26/A.04.10/
packet.Z
/opt/omni/databases/vendor/sap/dec/alpha/osf1-4/A.04.10/
packet.Z
/opt/omni/databases/vendor/sap/dec/alpha/osf1-4/A.04.10/
require.dat
what(1) Output:
/opt/omni/databases/vendor/sap/gpl/i386/linux-60/A.04.10/
packet.Z:
None
/opt/omni/databases/vendor/sap/hp/s800/hp-ux-1020/A.04.10/
packet.Z:
None
/opt/omni/databases/vendor/sap/hp/s800/hp-ux-11/A.04.10/
packet.Z:
None
/opt/omni/databases/vendor/sap/ibm/rs6000/aix-42/A.04.10/
packet.Z:
None
/opt/omni/databases/vendor/sap/sun/sparc/solaris-26/A.04.10/
packet.Z:
None
/opt/omni/databases/vendor/sap/dec/alpha/osf1-4/A.04.10/
packet.Z:
None
/opt/omni/databases/vendor/sap/dec/alpha/osf1-4/A.04.10/
require.dat:
None
cksum(1) Output:
2964783613 966776 /opt/omni/databases/vendor/sap/gpl/i386/
linux-60/A.04.10/packet.Z
33902731 1329979 /opt/omni/databases/vendor/sap/hp/s800/
hp-ux-1020/A.04.10/packet.Z
4249096554 1322505 /opt/omni/databases/vendor/sap/hp/s800/
hp-ux-11/A.04.10/packet.Z
3393402820 1188666 /opt/omni/databases/vendor/sap/ibm/
rs6000/aix-42/A.04.10/packet.Z
3871788517 1239699 /opt/omni/databases/vendor/sap/sun/sparc/
solaris-26/A.04.10/packet.Z
3610240235 1872690 /opt/omni/databases/vendor/sap/dec/alpha/
osf1-4/A.04.10/packet.Z
1650591381 18 /opt/omni/databases/vendor/sap/dec/alpha/
osf1-4/A.04.10/require.dat
Patch Conflicts: None
Patch Dependencies: None
Hardware Dependencies: None
Other Dependencies:
If any newer SSP for the SAP is installed
on your system, you must re-apply the SSP after
installing this SAP patch.
PHSS_28331:
Release Date: Available
Id = HSLco37193 SR:H555008807
PHSS_28331 (or later) is required for this defect fix.
PHSS_28232:
Release Date: Available
Id = HSLco37193 SR:H555008807
Bad catalog access message is displayed without PHSS_28232
(or later).
PHSS_28341:
Release Date: Available
Id = HSLco37193 SR:H555008807
PHSS_28341 (or later) is required for this defect fix.
PHSS_27602:
Release Date: Available
Id = HSLco37193 SR:H555008807
Id = HSLco37783 SR:H555008908
PHSS_27602 (or later) is required for these defect fixes.
PHSS_27456:
Release Date: Available
Id = HSLco33795 SR: H555007605
PHSS_27456 (or later) is required for this enhancement.
Supersedes:
PHSS_26887 PHSS_27452 PHSS_28343
Equivalent Patches:
PHSS_28724:
s700: 11.00 11.11 11.20
s800: 11.00 11.11 11.20
Patch Package Size: 7800 KBytes
Installation Instructions:
Please review all instructions and the Hewlett-Packard
SupportLine User Guide or your Hewlett-Packard support terms
and conditions for precautions, scope of license,
restrictions, and, limitation of liability and warranties,
before installing this patch.
------------------------------------------------------------
1. Back up your system before installing a patch.
2. Login as root.
3. Copy the patch to the /tmp directory.
4. Move to the /tmp directory and unshar the patch:
cd /tmp
sh PHSS_28723
5a. For a standalone system, run swinstall to install the
patch:
swinstall -x autoreboot=true -x match_target=true \
-s /tmp/PHSS_28723.depot
By default swinstall will archive the original software in
/var/adm/sw/patch/PHSS_28723. If you do not wish to retain a
copy of the original software, you can create an empty file
named /var/adm/sw/patch/PATCH_NOSAVE.
WARNING: If this file exists when a patch is installed, the
patch cannot be deinstalled. Please be careful
when using this feature.
It is recommended that you move the PHSS_28723.text file to
/var/adm/sw/patch for future reference.
To put this patch on a magnetic tape and install from the
tape drive, use the command:
dd if=/tmp/PHSS_28723.depot of=/dev/rmt/0m bs=2k
Special Installation Instructions:
PHSS_28723:
NOTE!
This Patch has to be installed on the Installation
Server host.
The OB2 SAP agent must be redistributed to the SAP
client system(s) after the installation of the patch
in order to get the fixes into effect.
For distribution of the SAP agent, refer to
the OmniBackII Installation guide.
Patch includes the following Site Specific Patches:
SSPUX410_014
SSPUX410_023
SSPUX410_025
SSPUX410_027
SSPUX410_033
SSPUX410_036
SSPUX410_050
SSPUX410_064
SSPUX410_067
-----End of Document ID: PHSS_28723------------------------------------------
Document ID: PHSS_28578
Date Loaded: 20030404
Title: s700_800 10.X OV OB3.50 patch - SSEA packet
Patch Name: PHSS_28578
Patch Description: s700_800 10.X OV OB3.50 patch - SSEA packet
Creation Date: 03/03/24
Post Date: 03/04/04
Hardware Platforms - OS Releases:
s700: 10.00 10.01 10.10 10.20
s800: 10.00 10.01 10.10 10.20
Products:
OmniBackII A.03.50
Filesets:
OMNIBACK-II.OMNI-SSEA-P,A.03.50
Automatic Reboot?: No
Status: General Release
Critical: No
Path Name: /hp-ux_patches/s700_800/10.X/PHSS_28578
Symptoms:
PHSS_28578:
Id = HSLco37090 SR:H555008776
SSEA LVM BC backup fails with:
"[Critical] From: SSEA
<hostname> "" Time:<time>
Command "/usr/bin/raidscan -p <port>"
failed with exit code 238.
For details check the following log directories:
Log file directory in operation:
/var/opt/omni/log/<session_ID>/curlog<num>Log
file directory for automatic storing:
/var/opt/omni/log/<session_ID>/tmp<num>"
Id = HSLco37449 SR:H555008860
When resolving ssea reports all of its data for every
single object to be backed up.
Id = HSLco40537 SR:H555009863
When backing up very large SAP databases with SSEA
split mirror, backups can fail with error:
"BR280I Time stamp <time>
BR296I Split of mirror disks successful
BR274E File /<sapdata_path>/system.data1 not found"
PHSS_27591:
Id = HSLco32398 SR:H555007043
When there is a firewall between the application and
the backup host, the split mirror backup fails.
Id = HSLco32470 SR:H555007071
Resolving performance is poor.
Id = HSLco33214 SR:H555007361
SSEA backup fails with:
"[Major] From: SSEA
<hostname> "" Time: <time>
[224:106] Resolving of object <object_path> has
failed. (Search for backup logical volume failed.)"
Id = HSLco35074 SR:H555008259
SSEA backup fails with:
"[Critical] From: SSEA
<hostname> "" Time:<time>
Failed to get pair for LDEV <ldev#> in RAID <seq#>.
(Details unknown.)"
Id = HSLco36105 SR:H555008599
SSEA backup fails with:
"[Critical] From: SSEA
<host> <mailto:SSEA
<host>
"" Time:<time>
Command "/usr/bin/pairdisplay -g" failed with exit
code 242."
Id = HSLco36476 SR:H555008656
SSEA backup fails with:
"[Major] From: SSEA
<hostname> "" Time:<time>
[224:106] Resolving of object <object_name> has
failed. (Search for backup logical volume failed.)"
Id = HSLco36975 SR:H555008750
The SSEA SMB session on the backup host abnormally ends
when trying to activate backup volume group after the
paired LDEVs have been split.
PHSS_26215:
Id = HSLco32218 SR: H555006986
Horc instance number is not configurable.
Id = HSLco32253 SR: H555006993
SSEA agent reports disks in SIMPLEX state although
they are in PAIR state in HORCM.
Id = HSLco32264 SR: H555006994
OmniBack II SSEA Integration does not work with
logical devices with XP LUN number greater than 128.
Id = HSLco32274 SR: H555006996
Performance of SSEA integration drastically decreases
after the installation of PHSS_25817/PHSS_25818.
PHSS_25817:
Id = JAGad48627 SR:8606179403
If preexec script fails OmniBack II by default just
aborts the agent and exits. It does not run post-exec
script or clean up.
Id = NSMex04226
Restore fails with:
"[Major] From: SYMA
<hostname> "" Time: <time>
[223:325] Could not activate volume group
/dev/sg_sap.
[Major] From: SYMA
<hostname> "" Time: <time>
[223:363] Could not prepare mirror disks of object
/sg_sap for backup.
(Activation of volume group failed.)".
Id = HSLco30300 SR:H555006603
Split mirror backup fails with:
"[Critical] From: SSEA
<host> "" Time: <time>
Command "/etc/horcmgr" failed with exit code 3.
For details please check log directories:
Log file directory in operation:
/var/opt/omni/log/yyyy-mm-dd-xx/curlogxx
Log file directory for automatic storing:
/var/opt/omni/log/yyyy-mm-dd-xx/tmpxx".
Id = HSLco31032 SR:H555006753
Split mirror backup session fails with:
"[Critical] From: SSEA
<host> "" Time: <time>
Failed to find T-VOL/R-Vol of LDEVs.
[SseMapLdevToRdsk] Unable to found /dev/rdsks
file for LDEV = <number>".
Id = HSLco31434 SR:H555006835
Unexpected close reading message from the agent on the
Backup System (SSEA abnormally ends on R2).
Id = HSLco30701 SR:H555006685
Resolving fails on the Application host. The spt inq
structure returns corrupted results.
Id = HSLco31490 SR:H555006844
SSEA integration backup fails with:
"[Critical] From: SSEA
<host_name> "" Time: <time>
Command "/etc/horcmgr" failed with exit code 3.
[Critical] From: SSEA
<host_name> "" Time: <time>
Failed to start RAID Manager instance.
(Command /etc/horcmgr failed.)".
PHSS_24425:
Id = NSMex04086
Session status is "Completed/Failures" although there
is no any indication of errors.
Id = NSMex04209
SSEA Integration backup fails with an error:
"[Critical] From: SSEA
<hostname> "" Time: <time>
Failed to find <volume/volume No.> of LDEVs.".
Id = NSMex04216
SSEA Integration backup reports the following warning:
"[Warning] Cascading structure of BC pairs found
(THIS IS UNSUPPORTED).".
Id = NSMex04392
SSEA Integration backup fails with an error:
"Filesystem <path> could not be mounted.".
Id = NSMex04267
SSEA Integration backup fails with an error:
"[61:1005] Got unexpected close from Split Mirror
Agent.".
Id = HSLco23886
LVM Mirror (XP Campus Cluster) is not supported
within OmniBack II SSEA Integration.
PHSS_22436:
Id = NSMex03360
SSEA Integration split does not appear to mount some
filesystems.
Id = NSMex03700
Disk resolving failed on Backup Host.
Id = NSMex03717
a) SSEA integration backup fails with an error:
"[Major] From: SSEA
<hostname> "" Time: <time>
[224:106] Resolving of object "filename" has failed.
(Cannot find block device path name of a logical
volume)"
b) SSEA Integration backup fails with an error:
"[Major] From: SSEA
<hostname> "" Time: <time>
File system <filesystem> could
not be mounted to . (Invalid filesystem type.)"
Id = NSMex03482
Disk synchronization messages are incorrect.
Id = HSLco22201
OmniBack II SSEA integration is not supported on Sun
Solaris operating system.
Id = NSMex03651
Disk synchronization fails with:
"[Critical] From: SSEA
<hostname> "" Time: <time>
[225:110] Mapping from LDEV to character device
file or disk failed for LDEV <dev> on
array <array>. (Unable to find character device
file for SureStoreE XP256 disk (LDEV))."
Id = NSMex03673
Backup fails with the following message:
"[Critical] From: SSEA
<hostname> "" Time: <time>
Command "/usr/bin/pairdisplay -g" failed with
exit code 242.".
Id = NSMbb39679
OmniBack II aborts Business Copy split mirror
backup because one of the disks in a pair is in
status COPY.
Id = NSMex03547
SSEA Agent intermittently fails to resolve objects.
Id = NSMex03739
Pre- and post-exec scripts return invalid exit status.
Id = NSMex03913
SSEA backup fails with the following message:
"[Critical] From: SSEA
<hostname> "" Time: <time>
Command "/usr/bin/pairdisplay -g" failed with
exit code 221.".
Id = NSMex03960
SSEA backup fails with the following error:
"Failed to start RAID Manager instance.
(Unable to find SureStoreE XP256 COMMAND device
file.)".
Id = NSMex03850
Sometimes volumes cannot be mounted on JFS 3.3
filesystem.
Id = NSMex03749
Mount function does not restore mount options.
Id = NSMex03563
Mounting of a filesystem fails.
Id = NSMex03931
OmniBack II SSEA Integration does not work on XP 512
for LDEVs with XP LUN addresses above 128.
Defect Description:
PHSS_28578:
Id = HSLco37090
If the LVM mirroring is done between two XP boxes with
the BC configuration on the second XP box and the BC
license present only on the second XP box, the raidscan
command fails on the first XP box causing the session
to fail.
Resolution:
BC license on the first XP is not needed. When
executing the raidscan command, the SSEA session does
not fail if the raidscan command fails, but just marks
the rdsks and LDEVs from the first XP box with an
error. The marked rdsks and LDEVs are skipped later in
the session.
Id = HSLco37449
Extensive reporting is only needed in case of errors,
so reporting data for every object can mean a lot of
unwanted information, especially in big environments.
Resolution:
New environment variable is introduced:
SSEA_RESOLVING_DISPLAY. Its default value is 1. Set
it to 0 if you want to switch off extensive object
data reporting.
Id = HSLco40537
In split mirror environment with very large SAP
databases, it can happen that the size of the message
buffer that OmniBack II uses is too small to fit in
for the complete list of SAP files to be backed up.
Resolution:
New environment variable is introduced: OB2IPCBUFSIZE.
In order to solve this problem, the buffer size can
be increased by setting the OB2IPCBUFSIZE environment
variable in the .omnirc file on CM, R1 and R2 hosts,
specifying the desired amount of memory to be used
for the buffer.
Please read the following instructions and make sure
that the patches listed in "Other Dependencies" section
(see below) are installed and the environment
variable is set on Cell Server, R1 and R2 systems before
running the backup!
How to determine the buffer size?
---------------------------------
N_obj: number of objects (files)
N_fs: number of file systems
N_lvmvg: number of volume groups
N_dg: number of disk groups
N_rdsk: number of rawdisks
Obj: Object Name
ObjBack: Object Backup Name
MntPathLen: Path name on backup (R2) host
(example: /var/opt/omni/tmp/App_host)
fsmnt: File System Mount Point
fsdev: File System Device File
(example: /dev/dsk/[c0t1d1,lvol1])
vg: Volume group
(ex: /dev/vg01)
dg: Disk group (VxVM) - dependence on mapfile
which is required for creating disk group
(example:/dev/vx/dsk/dg01)
rdsk: Raw disk file name
(example: /dev/rdsk/c1t1d1)
AvgLen_<xxx> average length of <xxx>
There are two different buffers used:
1. BSM <-> R1
2. R1 <-> R2
Calculating the BSM <-> R1 buffer size
--------------------------------------
MsgSize_BSM_R1 = N_obj * (AvgLen_Obj + 1 + MntPathLen)
Calculating the R1 <-> R2 buffer size
-------------------------------------
MsgSize_R1_R2 =
N_obj*(AvgLen_Obj+1+AvgLen_ObjBack) +
N_fs*(AvgLen_fsmnt*2 + MntPathLen + AvgLen_fsdev*2)+
N_lvmvg*(AvgLen_vg*2) + N_dg*(AvgLen_dg*2) +
N_rdsk*(AvgLen_rdsk*2)
Calculating the OB2IPCBUFSIZE value
-----------------------------------
OB2IPCBUFSIZE > max (MsgSize_BSM_R1, MsgSize_R1_R2)
RESTORE NOTE:
-------------
If restore is started using the sapbda utility,
the variable OB2IPCBUFSIZE must be exported to
environment prior to starting sapbda.
Part of SSPUX350_088.
PHSS_27591:
Id = HSLco32398
OmniBack II selects by random the port to use and than
checks if it is free. When there is a firewall between
the application and the backup host, not all the ports
can be used, but just those in a specified range.
Resolution:
Two environment variables are added to set the port
range in .omnirc file that can be used by OmniBack II:
SSEA_RM_PORT_LOW
SSEA_RM_PORT_HIGH
Id = HSLco32470
In the resolving phase SSEA executes two ioscan
commands in the SseXIoScanRdsk and ScsiIquiry
functions. Since these two functions are called
several times the resolving performance decreases,
especially in big environments.
Resolution:
SSEA executes just one ioscan command in the
SseXIoScanRdsk and ScsiIquiry functions. The ioscan
output is cached into a buffer and parsed for
information twice.
Id = HSLco33214
In case of non-XP rdsk, SSEA can not find the volume
group belonging to this rdsk and resolving can not
be done.
Resolution:
SSEA finds and checks all the rdsks belonging to an LDEV
on the R2 side. Than it uses only those rdsks which are
included in a volume group, in this way skips the non-XP
rdsks.
Id = HSLco35074
When there are more than one smb sessions running
simultaneously, horcm instances could be attached to
the same command device.
Resolution:
SSEA retries the getldev() call for 10 times. The
timeout before calling the getldev() API again is
randomly set. From now on SSEA tries to attach up
to 5 command devices if necessary.
Id = HSLco36105
A time out occurs on remote communication, and HORC
manager fails to re-execute.
Resolution:
A new environment variable SSEA_RM_TIMEOUT is
introduced. Its default value is 6000 milliseconds.
Id = HSLco36476
When mapping the LDEVs to the appropriate rdsks,
rdsks statuses are not correctly updated.
Resolution:
Mapping is done correctly.
Part of SSPUX350_083.
Id = HSLco36975
When the LDEVs belonging to a volume group are in PAIR
status and the SSEA smb session is started on some of
these LDEVs, the vgchange command on this volume group
takes a long time. After splitting the disks on on the
R2 side, the LDEVs included in the SMB session are in
PSUS state, the rest of the LDEVs are still in PAIR
state and vgchange command can not proceed, which
causes the session to ends abnormally.
Resolution:
If the SMB_SPLIT_ENTIRE_VG environment variable is set
to 1 in the .omnirc file on both hosts, then all the
LDEV pairs included in the backup volume group are
synchronized and split.
Part of SSPUX350_084.
PHSS_26215:
Id = HSLco32218
Horc instance number is not configurable.
Resolution:
Horc instance number can be configured using new
environment variables, SSEA_RMINST_LOW and
SSEA_RMINST_HIGH. When set in ${OMNI_HOME}/.omnirc
file, these variables set instance number range. Default
values for SSEA_RMINST_LOW and SSEA_RMINST_HIGH
are 50 and 80, respectively.
Part of SSPUX350_070.
Id = HSLco32253
Incorrect comparison of the strings causes incorrect
state of the disks reported.
Resolution:
SSEA agent properly reports disk state.
Id = HSLco32264
SSEA agent creates invalid configuration files for
logical devices exported to LUN's above 128.
Resolution:
New environment variable is introduced: SSEA_XP_PORTS.
Setting the variable to the value "FC" in
${OMNI_HOME}/.omnirc file enables OmniBack II SSEA
Integration to work properly with logical devices
exported to XP LUN's greater than 128.
Id = HSLco32274
Multiple ioscan calls when extracting needed data
cause bad performance.
Resolution:
Scripts for obtaining data needed by OmniBack II SSEA
Integration are improved.
PHSS_25817:
Id = JAGad48627
If pre-exec script fails, cleanup does not start
post-exec script.
Resolution:
New environment variable is introduced. When
SSEA_ALWAYS_POST_SCRIPT in .omnirc file on
application host is set to 1, post-exec script
is always executed.
Id = NSMex04226
Backup is made in SSEA/split mirror backup environment
with the Application host in the cluster. When
restoring object on the Backup host (R2), which is not
in the cluster the cluster tag (-c y) from the
Application host is also restored, so the volume group
can not be activated properly.
Resolution:
By default the cluster tag on the Backup host (R2) is
disabled with the "vgchange -q n -c n" command. To
enable the cluster tag on Backup host, set the new
environment variable SMB_CLUS_DEACT=1 in the
/opt/omni/.omnirc file.
Id = HSLco30300
The command /etc/horcmgr fails if the command
device is used by another split mirror session.
Resolution:
New environment variables are introduced
SSEA_RM_RETRY and SSEA_RM_SLEEP.
SSEA_RM_RETRY defines the number of retries.
SSEA_RM_SLEE defines sleeping time in seconds,
before new retry is started.
Id = HSLco31032
The resolving from LDEVs to rdsks on the backup host
fails due to incorrect reporting of LDEVs to rdsks.
Resolution:
The resolving from LDEVs to rdsks is corrected.
Id = HSLco31434
SSEA agent on R2 does not read the number of rdsk
from the R1. Bug is produced while fixing the
NSMex04787 case on NT platform, but affected the
SSEA agent on the HP-UX platform.
Resolution:
The correct number of strings is read from the SSEA
agent on the R2 side.
Id = HSLco30701
The SCTL_InquiryDisk function returns empty or
corrupted inq structure.
Resolution:
The ioctl system function writes its output directly
to the inq structure. The "mapping from rdsks to LDEVs"
and the ScsiInquiry are enhanced.
Part of SSPUX350_057.
Id = HSLco31490
SSEA can not start the selected HORCMINST instance
number. It is already started by another RaidManager
process.
Resolution:
SSEA tries to start the instance with different
instance number up to five times.
PHSS_24425:
Id = NSMex04086
Message level of a resolving failure in XP environment
is set to "Normal" instead of "Major".
Resolution:
Message level is corrected.
Id = NSMex04209
If backup devices are exported to more than one port
and original devices have more than two mirrors, when
session is started and two of these ports are used for
that session, SSEA Integration detects more mirrors
than it is allowed.
Resolution:
Parsing of raidscan() output is improved.
Id = NSMex04216
If there are two or three mirror disks to source
disk, OmniBack II reports that cascading structure is
found although cascading structure is present only
when there are mirror disks to targer disk.
Resolution:
Searching for cascading structure is excluded as
this feature is not supported with OmniBack II
A.03.50 version.
Id = NSMex04392
Incorrect filesystem options are sent to R2 side.
For HFS filesystems the entries in the mnttab file
are not updated promptly.
Resolution:
Correct filesystem options are sent to R2 side.
/etc/mnttab is promptly updated for HFS filesystem.
Id = NSMex04267
SSEA API fails after 60 seconds during the change of
volume groups. SMB_TIMEOUT is hardcoded to 60 seconds.
Resolution:
SMB_TIMEOUT can be configured in .omnirc file for
situations where the changing of volume groups takes
more than one minute.
Part of SSPUX350_037.
Id = HSLco23886
LVM Mirror (XP Campus Cluster) is not supported within
OmniBack II SSEA Integration.
Resolution:
LVM Mirror (XP Campus Cluster) is supported within
OmniBack II SSEA Integration.
PHSS_22436:
Id = NSMex03360
XP256 Raid Manager's pairdisplay command returns
invalid status which causes some raw disks to fail
during resolving.
Resolution:
Status checking changed to ignore invalid status from
pairdisplay command.
Id = NSMex03700
If there is a lot of backup objects (usually case with
SAP databases) and these objects are placed in volume
group with a lot of stripped disks, then the size of
the internal message sent from SSEA-R1 to SSEA-R2 can
overflow hardcoded 100k limit.
Resolution:
New message format reduces message size significantly.
Part of the SSPUX350_007.
Id = NSMex03717
a) OmniBack II does not handle soft links correctly.
b) SSEA integration backup does not work properly in
case that a single session contains both filesystem
and rawdisk objects.
Resolution:
Fixes are implemented in ssea.
Part of the SSPUX350_007.
Id = NSMex03482
Disk synchronization failure reported as "Normal".
Resolution:
Message statuses are properly reported.
Id = HSLco22201
OmniBack II SSEA integration is not supported on Sun
Solaris operating system.
Resolution:
OmniBack II SSEA integration is supported on Sun
Solaris 7 and 8 operating systems.
Please find the integration manual in the
/usr/omni/bin/utilns directory after the patch is
installed.
Id = NSMex03651
IPC buffer for communication between SSEA Agents on
backup and application host is too small.
Resolution:
IPC buffer increased.
Id = NSMex03673
Pairdisplay command fails in ServiceGuard environment.
Resolution:
Hostname resolving is improved.
Id = NSMbb39679
OmniBack II does not treat status COPY as a valid
status.
Resolution:
OmniBack II waits (for configurable timeout) for the
second disk to change the status to PAIR.
Environment variables are:
SSEA_SYNC_SLEEP_TIME = <time in seconds>
SSEA_SYNC_RETRY = <number of retries>
Default values are 5 for SSEA_SYNC_SLEEP_TIME and
10 for SSEA_SYNC_RETRY.
Id = NSMex03547
Resolving of objects fails if stat() function reports
error for any entry in /etc/mnttab.
Resolution:
Irrelevant errors are skipped during the resolving.
Id = NSMex03739
Pre- and post-exec scripts return invalid exit status
because of timing problem.
Resolution:
Environment variable OB2EXECTIMEOUT is introduced.
Variable represents timeout (in seconds) after the end
of pre- and post-exec script. Default value is 0.
Recommended value is between 5 and 10 seconds.
Id = NSMex03913
Pairdisplay command fails if two sessions are started
at the same time.
Resolution:
SSEA Agent correctly detects service port numbers
availability.
Id = NSMex03960
SSEA Agent uses only those disks for which ioscan
reports state CLAIMED. Backup fails due to a fact that
some of the disks needed for session are in state SCAN.
Resolution:
Disks in state SCAN are reported as well as those in
state CLAIMED.
Id = NSMex03850
Changes made for JFS 3.3 support cause mount problems
on HP-UX 10.20 platform.
Resolution:
Code now properly works also for the HP-UX 10.20
platform.
Part of SSPUX350_016.
Id = NSMex03749
Filesystem is not mounted with the options that were
used before split mirror backup was performed.
Resolution:
Command line mount command is used instead of mount
function for vxfs filesystem.
Id = NSMex03563
Mount operation does not work properly on systems
with Online JFS 3.3 installed.
Resolution:
Mount API uses proper arguments.
Id = NSMex03931
Invalid configuration files are created for LDEVs
exported to LUN addresses above 128.
Resolution:
New environment variable SSEA_XP_PORTS is introduced.
Its value has to be set to "FC" when using Fibre channel
and LUN addresses greater than 128.
Part of SSPUX350_032.
SR:
H555009863 H555008776 H555008860 H555008656 B554000692
H555007043 H555008599 H555007071 B554000869 B554000879
H555007361 H555008750 H555008259 H555006993 H555006994
H555006986 H555006996 H555006685 H555006753 8606179403
H555006844 H555006835 H555006603 H555005488 H555005717
H555005689 H555005681 H555004065 H555005289 H555003697
B554000781 B554000676 B554000847 B554000829 H555004533
H555004741 H555003490 H555003716 B554000521 B554000612
H555003817 H555004474 B554000803 B554000491 H555004919
Patch Files:
/opt/omni/databases/vendor/ssea/hp/s800/hp-ux-1020/A.03.50/
packet.Z
/opt/omni/databases/vendor/ssea/hp/s800/hp-ux-11/A.03.50/
packet.Z
/opt/omni/databases/vendor/ssea/sun/sparc/solaris-26/
A.03.50/packet.Z
/opt/omni/databases/vendor/ssea/sun/sparc/solaris-26/
A.03.50/require.dat
what(1) Output:
/opt/omni/databases/vendor/ssea/hp/s800/hp-ux-1020/A.03.50/
packet.Z:
None
/opt/omni/databases/vendor/ssea/hp/s800/hp-ux-11/A.03.50/
packet.Z:
None
/opt/omni/databases/vendor/ssea/sun/sparc/solaris-26/
A.03.50/packet.Z:
None
/opt/omni/databases/vendor/ssea/sun/sparc/solaris-26/
A.03.50/require.dat:
None
cksum(1) Output:
1343273602 2050307 /opt/omni/databases/vendor/ssea/hp/s800/
hp-ux-1020/A.03.50/packet.Z
3097561959 2059081 /opt/omni/databases/vendor/ssea/hp/s800/
hp-ux-11/A.03.50/packet.Z
3903783657 1550093 /opt/omni/databases/vendor/ssea/sun/
sparc/solaris-26/A.03.50/packet.Z
1830950196 19 /opt/omni/databases/vendor/ssea/sun/sparc/
solaris-26/A.03.50/require.dat
Patch Conflicts: None
Patch Dependencies: None
Hardware Dependencies: None
Other Dependencies:
If any newer SSP for the SSEA is installed
on your system, you must re-apply the SSP after
installing this SSEA patch.
PHSS_28727:
Release date: Late April
Id = HSLco40537 SR:H555009863
PHSS_28727 is required for this defect fix.
PHSS_28725:
Release date: Late April
Id = HSLco40537 SR:H555009863
PHSS_28725 is required for this defect fix.
PHSS_28570:
Release date: Available
Id = HSLco40537 SR:H555009863
Bad catalog access message is displayed without PHSS_28570.
PHSS_28017:
Release Date: Available
Id = HSLco40537 SR:H555009863
PHSS_28017 is required for this defect fix.
Supersedes:
PHSS_22436 PHSS_24425 PHSS_25817 PHSS_26215 PHSS_27591
Equivalent Patches:
PHSS_28579:
s700: 11.00 11.11 11.20
s800: 11.00 11.11 11.20
Patch Package Size: 5590 KBytes
Installation Instructions:
Please review all instructions and the Hewlett-Packard
SupportLine User Guide or your Hewlett-Packard support terms
and conditions for precautions, scope of license,
restrictions, and, limitation of liability and warranties,
before installing this patch.
------------------------------------------------------------
1. Back up your system before installing a patch.
2. Login as root.
3. Copy the patch to the /tmp directory.
4. Move to the /tmp directory and unshar the patch:
cd /tmp
sh PHSS_28578
5a. For a standalone system, run swinstall to install the
patch:
swinstall -x autoreboot=true -x match_target=true \
-s /tmp/PHSS_28578.depot
By default swinstall will archive the original software in
/var/adm/sw/patch/PHSS_28578. If you do not wish to retain a
copy of the original software, you can create an empty file
named /var/adm/sw/patch/PATCH_NOSAVE.
WARNING: If this file exists when a patch is installed, the
patch cannot be deinstalled. Please be careful
when using this feature.
It is recommended that you move the PHSS_28578.text file to
/var/adm/sw/patch for future reference.
To put this patch on a magnetic tape and install from the
tape drive, use the command:
dd if=/tmp/PHSS_28578.depot of=/dev/rmt/0m bs=2k
Special Installation Instructions:
PHSS_28578:
NOTE!
This patch has to be installed on the Installation
Server host.
The OB2 SSEA agent must be redistributed to the SSEA
client system(s) after the installation of the patch
in order to get the fixes into effect.
For distribution of the SSEA agent, refer to
the OmniBackII Installation guide.
Patch includes the following Site Specific Patches:
SSPUX350_007
SSPUX350_016
SSPUX350_032
SSPUX350_037
SSPUX350_057
SSPUX350_070
SSPUX350_083
SSPUX350_084
SSPUX350_088
-----End of Document ID: PHSS_28578------------------------------------------
Document ID: PHSS_27297
Date Loaded: 20030404
Title: s700_800 10.20 OV ITO6.0X Solaris Agent Patch A.06.11
Patch Name: PHSS_27297
Patch Description: s700_800 10.20 OV ITO6.0X Solaris Agent Patch A.06.11
Creation Date: 03/04/03
Post Date: 03/04/04
Hardware Platforms - OS Releases:
s700: 10.20
s800: 10.20
Products:
OpenView IT/Operations 6.0
Filesets:
OVOPC-CLT.OVOPC-SOL-CLT,A.06.00
Automatic Reboot?: No
Status: General Release
Critical: No
Path Name: /hp-ux_patches/s700_800/10.X/PHSS_27297
Symptoms:
PHSS_27297:
- SR: H555003664
option "-" of dmesg is not supported any more
- SR: H555006719
If the agent is running as a non-root user, when the
management server processes are restarted, the agent has
to be restarted, else messages are buffered.
- SR: H555006934
After agent installation internal messages are sent with
wrong codeset.
- SR: H555008352
ITO agent installation check on Solaris 2.9
- SR: 8606213476
The distribution to nodes may hang or fail. This is more
likely to happen while distributing to Windows NT/2000
nodes rather than on UNIX nodes. On Windows NT/Windows
2000 nodes the control agent may produces a Dr. Watson
error.
- SR: 8606217814
If customer calls agent init script manually from
non posix shell it will fail.So shell definition need
to be added.
- SR: 8606222554
Certain policies in VPW do not work as expected, for
example:
VP_WIN-WINS-FwdAllInformation
VP_WIN-WINS-FwdAllWarnError
VP_WIN-DHCPCl_FwdAllInfo
VP_WIN-DHCPCl_FwdAllWarnError
This problem can also occur for VPO during condition
matching. Matching the application and object attributes
is now case sensitive. For example, a message with
application "TEST" is matched but application "tEST" is
unmatched.
- SR: 8606227840
Variables in the template default message key are not
resolved for unmatched messages.
- SR: 8606233602
If using a pattern like '<*.prefix>ERR<*.suffix>', the
prefix variable will get assigned a wrong text if it
should be empty.
- SR: 8606242614
Messages are incorrectly suppressed by the logfile
encapsulator if "suppress identical output messages" is
specified and the messages differ only in the values of
<$LOGFILE> and/or <$LOGPATH>.
- SR: 8606244523
When using the syntax <`script`> in the logfile template
and the script returns the same logfile name twice, the
opcle will abort.
- SR: B555007980
Local automatic actions are started immediately, even
though the agent MSI is enabled in divert mode and the
Immediate Local Automatic Action box is not checked.
- SR: B555008220
The <$MSG_TIME_CREATED> variable is not substituted in
the message template.
- SR: B555008838
The event correlation engine creates a "Time cannot go
backwards" error if the system is very busy.
- SR: B555009745
The template default of the object field of a monitor
template is not used.
- SR: B555010620
Some messages are missing in the Japanese message
catalogue. You get a Cannot generate message error.
- SR: B555010966
A message key relation containing <*> does not always
match message keys correctly. This results in messages
not being acknowledged when they should.
- SR: B555011184
opcagt fails to start opcctla if it is started as
./opcagt and /opt/OV/bin/OpC is not in the search PATH
- SR: B555011594
The original message text of a logfile encapsulator
message is wrong if <$LOGPATH> or <$LOGFILE> is used.
- SR: B555011638
The pattern matching cannot match the new line
character(s) of multiline messages.
- SR: B555011979
The pattern matching hangs if only single byte Japanese
HANKAKU KANA characters are used.
- SR: B555011990
The ECS event log (ecevilg) has an invalid time
difference to the next message which can cause the ECS
simulator to hang or appear to hang when loading an event
log file with such values.
- SR: B555012210
ECS circuit using reset on unless node causes opceca to
abort.
- SR: B555012929
If you run opcdista from commandline, you don't get any
useful messages, only the internal status letters.
For supportability, it would be better to have
some explicit status and error reporting.
- SR: B555013371
Sometimes the new scheduled action template configuration
is not loaded after a distribution. Instead, the old
scheduled actions are still started.
- SR: B555013435
The message agent opcmsga hangs unpredictably. This is
more likely to happen on systems with a very high ICMP
traffic.
- SR: B555013495
In Japanese environments programs using the agent APIs
can fail with errors on invalid or incompatible codesets.
- SR: B555013620
Support for pmd's "u" option needed in opctrapi: use the
UDP packet's address as source of the trap.
- SR: B555013719
Message agent doesn't stop message buffering when the
management server is available again after a network
outage, fixed DNS problem or similar.
This can happen when the agent restarts/the machine
reboots during the network problem occured.
- SR: B555013794
The current directory should be removed from the agent's
environment PATH. That way only files can be executed
that are either specified with the full path or the path
is explicitly specified in the PATH.
- SR: B555013891
In MoM environments, opcmsga does not return action
responses to SECONDARY managers, if their name is not
resolveable.
- SR: B555014093
opcmona may crash (UNIX) or doesn't process all SCHEDULE
templates (Windows) when using SCHEDULE templates.
- SR: B555014132
During a distribution the agent may report an error like:
ITO responsible manager configuration. (OpC30-1203)
Cannot open file \usr\OV\tmp\OpC\cfgchg.
System Error Number: 13 (d) - The data is invalid.
(OpC20-63)
- SR: B553000162
After opcagt -stop, opcagt -status does tell that the
control agent does not run although it is running and
sometimes you get following error in the message browser:
ouput of kill -0 differs from internal pids-table for
index <number> (OpC30-1094)
:
- SR: H555005793
after A.06.06 opcctla might core dump during
distribution
- SR: H555005720
vcs_monitor.sh script is missing from the NCS comm package
- SR: H555005837
Japanese catalogs are missing in A.06.06 patch
- SR: H555004515
Subagent cannot be stopped on Solaris 8
- SR: B555010879
opctrapi aborts during template distribution if
conditions with the 'Suppress Identical Output Messages'
features are used.
- SR: B555010899
opcdista requests distribution data from a wrong manager
if there is a secondary manager with the same short
hostname than the appropriate primary manager.
- SR: B555010948
Nested alternatives were not handled correctly in the
pattern matching algorithm, e.g. the pattern '[a|b]c|d'
was handled like '[a|b|d]c'.
- SR: B555010980
Traps without a SNMP variable are not matched because
server patch adds an extra attribute to the template.
:
- SR: 8606180891
The template default for the service name is not used.
- SR: 8606181988
The event interceptor doesn't forward on
"forward unmatched" if a "supress unmatched" condition
is used in a second template
- SR: B555010341
Agent sometimes does not start automatically after reboot
while manual start works fine.
- SR: 8606146160
Veritas Cluster was not supported on VPO for Sun
Solaris
PHSS_23824:
- The VPO A.06.03 patches for HP-UX and Solaris
do not work as expected in firewall environments:
While server port restrictions are still regarded,
client-side port restrictions are ignored.
- The event correlation process opcecm might crash
after processing several annotation nodes
- HPlwdce Kill(shutdown) scripts are missing.
PHSS_22885:
- Changes were required for the security add-on product
VantagePoint Advanced Security.
- The IT/O Agent API call opcagtmsg_send()
might leak memory if the opcmsgi isn't running.
- The opctrapi might abort with OpC30-104
- disk_mon.sh returns invalid values if the bdf command
returns more than one line output for a filesystem
(e.g. if the filesystem name exceeds its column width)
- ITO Agent might hang during ITA synchronisation
when transferring bigger files (>0.5 MB) from several
nodes to the ITO server at the same time
- swap_util monitoring does not work on Solaris 8
- in Japanese environment.
- Problems with allowed port range.
- In case of an error the ITO Agent might hang
during startup without terminating
PHSS_22255:
- Agent needs better handling for firewall environments.
- When executing large numbers of autoactions, some of them
were staying in 'running' state.
- opctrapi aborts after getting traps with unresolvable IP
address.
- The handling of '\' was different in the pattern
definition and the "matching pattern".
- the opcmsga reported Message Receiver service not
registered even if the connection to the server was ok
- Running a VBScript-tool on a unix node gave a strange
error message
- if buffer file size limitation is enabled the agent may
discard low-severity messages even if there is still
space in the buffer file
- swap_util template did not work on Solaris 8
in Japanese environment
Defect Description:
PHSS_27297:
- SR: H555006719
When a communication to a message receiver fails, the
message agent starts buffering messages. It periodically
checks if a server is alive by sending it ICMP packets.
If the server cannot be reached with ICMP packets, no RPC
communication is attempted. Sending ICMP packets is not
possible when the agent is running as a non-root user, so
the sending function cannot actually send anything.
Therefore we also never receive any replies and the
message agent will buffer messages forever. To fix this,
the internal state of the message agent is updated after
we tried to send an ICMP packet if the agent is running
as a non-root user.
- SR: H555006934
It is necessary to check nodeinfo file and then set
appropriate language (same like in nodeinfo) in start-up
script to start agent.
There are not all releases known where this defect should
be included.This should be checked from time to time.
- SR: 8606213476
While the agent receives several RPC calls, like "Start
Distribution", "Execute Action" or "Set Primary Manager"
in parallel, it may happen that the call results in a
conflict within the control agent, which causes the
control agent to bring a Dr. Watson window.
This conflict can also occur on UNIX but the control
agent doesn't die, rather the RPC request may fail.
With this version the RPC calls which could cause
conflicts are serialised.
- SR: 8606217814
To avoid problems with different shells an interpreting
shell has been defined explicitly.
- SR: 8606222554
The condition test for the message attributes
application, object and message group are always done
case sensitive, therefore a message with the application
"TEST" matches but "tEST" does not match.
With this patch an opcinfo flag is introduced, which
allows to switch between case sensitive and case
insensitive check.
flag : OPC_COND_FIELD_ICASE
type : boolean
default: FALSE
By setting this to true the policies mentioned above will
work.
- SR: 8606242614
The variables <$LOGFILE> and <$LOGPATH> were replaced
after the suppression rules were evaluated. Therefore the
comparison did not use the actual logfile name or path,
but compared the string "<$LOGFILE>" or "<$LOGPATH>".
- SR: 8606244523
The opcle aborts when a <`script`> returns a logfile name
twice. This is because of referencing and handling the
same file twice.
To fix this, the opcle checks whether the same logfile
has been returned already and when adding to the internal
list, each logfile gets added exactly once.
- SR: B555010966
The processing of the key relation is wrong for the log
file encapsulator. The problem is that all unresolved
entries followed by a resolved entry are removed.
Other unresolved entries are kept as is.
- SR: B555011184
The working directory for the ITO agent was changed
from /opt/OV/bin/OpC to /tmp to avoid problems if
the agent is running in an MC/SG environment.
- SR: B555011638
The pattern matching could not match the new line
character(s) of multi line messages. The following
changes have been made to allow this:
It is now possible to use ^M (\r) as a field separator.
A new pattern </> was introduced to match any number of
line breaks (UNIX style \n or NT style \r\n). <n/> will
match exactly n line breaks, for example <1/> will match
exactly one line break.
This change works only for sources that already can
create multi line messages (for example opcmsg or NT
event log), it does not allow multi line logfile
encapsulation.
This change requires changes for management server and
agent. Therefore a patch for the management server and
a patch for the agent is required to use the new
functionality.
- SR: B555012210
Linked with new ECS runtime library that contains
a fix for this problem.
- SR: B555012929
The opcdista communicates with the opcctla process via
stdin/stdout so if you run it from commandline, you only
see the status letters but don't know what they mean.
The new '-v' option prints more output, e.g.:
$ ./opcdista -v
0 - No distribution data available.
- SR: B555013435
One thread tried to read from a socket while another
thread closed it. This could happen due to missing
locking of global data. This data is now guarded by a
mutex.
- SR: B555013495
When tracing was added to the API functions a necessary
NLS initialisation was not done. This problem was
introduced only by the A.06.10 patches for HPUX.
- SR: B555013620
NNM 6.2 introduced an event option to pmd - "u". This
option specifies to prefer the IP address in an SNMPv1
trap's UDP header over the contents of the SNMPv1 trap
PDU's agent_addr field.
A new opcinfo variable OPC_USE_UDP_AS_TRAP_SOURCE was
added for opctrapi. If set to TRUE, opctrapi will use the
UDP address instead of the agent_addr.
- SR: B555013719
Message agent remains in buffering mode even when
the management server is available again.
The reason is that the agent wasn't able to resolve
the management server name to an IP address at startup
and the agent doesn't try again during runtime.
This has been fixed by checking for a resolvable name
every time a message should be buffered till the name can
be resolved, after this the normal checkalive mechanism
which handles buffered message takes place.
- SR: B555013891
Even if the IP address of the management server was
specified in the mgrconf file, it was not used except for
the primary manager. This behaviour was changed to give
the mgrconf file precedence over name resolution.
- SR: B555014093
opcmona may crash (UNIX) or doesn't process all SCHEDULE
templates (Windows) when using SCHEDULE templates.
This can occur when there are only spaces in
one of the schedule fields (Minute, Hour, Day of the
Month, Month, Year, Day of the Week).
You can verify this by going to the conf/OpC directory on
the node and doing an opcdcode monitor. When
there are entries like WEEKDAY " " the problem can occur.
Now the monitor agent treats sequences of spaces like
an empty string that is a wildcard and uses all valid
values in the possible range.
For WEEKDAY this is 0-6.
- SR: B555014132
During a distribution the agent may report error number
OPC30-1203/OPC20-63 when trying to access the cfgchg
file.
The cause for this problem is that there are several
processes trying to get exclusive access to this file
at the same time. The problem has been fixed by doing a
retry for 10 times in case the error should occur with a
delay of one second.
for SR's not listed in this section please see
the list of symptoms
:
check the list of the symptoms
Resolution:
check the list of the symptoms
:
NSMbb40742
- SR: B555010341
When the process ID of the 'opcctla -start' is the same
as of the running opcctla before the shutdown, the
internal logic concluded that the agent is already
running and did not start up the subprocesses.
for all other defects not listed in this section please see
the list of symptoms
Resolution:
check the list of the symptoms
PHSS_23824:
check the list of the symptoms
Resolution:
check the list of the symptoms
PHSS_22885:
check the list of the symptoms
Resolution:
check the list of the symptoms
PHSS_22255:
check the list of the symptoms
Resolution:
check the list of the symptoms
SR:
H555008352 H555006934 H555006719 H555005837 H555005793
H555005720 H555005007 H555004515 H555003664 H555003507
H555003505 H555003466 H555003277 H555002616 B555014132
B555014093 B555013891 B555013794 B555013719 B555013620
B555013495 B555013435 B555013371 B555012929 B555012210
B555011990 B555011979 B555011638 B555011594 B555011505
B555011184 B555010980 B555010966 B555010948 B555010899
B555010879 B555010620 B555010341 B555010079 B555009745
B555009212 B555009155 B555009152 B555008838 B555008314
B555008220 B555007980 B555007752 B555007709 B555007602
B555007426 B555006890 B555006267 B553000162 8606244523
8606242614 8606233602 8606227840 8606222554 8606217814
8606213476 8606181988 8606180891 8606146160 8606141434
8606137088
Patch Files:
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/opc_pkg.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/install/opcrclchk
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/install/opcrdschk
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/install/opcrndchk
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/install/opcroschk
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/install/opcrverchk
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/install/opcrinst
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/install/opcnsl
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/ana_disk.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/cpu_mon.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/disk_mon.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/last_logs.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/mailq_l.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/proc_mon.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/sh_procs.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/swap_mon.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/vp_chk.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/mondbfile.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/dist_mon.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/ssp_chk.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/vcs_monitor.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/opcfwtmp.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/actions/mailq_pr.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/actions/st_inetd.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/actions/st_syslogd.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/actions/st_mail.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/actions/dist_del.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/cmds/opcdf.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/cmds/opclpst.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/cmds/opcps.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/cmds/E10000Log.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/cmds/ssp_config.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/opc_pkg.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/install/opcrclchk
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/install/opcrdschk
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/install/opcrndchk
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/install/opcroschk
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/install/opcrverchk
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/install/opcrinst
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/install/opcnsl
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/ana_disk.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/cpu_mon.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/disk_mon.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/last_logs.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/mailq_l.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/proc_mon.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/sh_procs.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/swap_mon.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/vp_chk.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/mondbfile.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/dist_mon.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/ssp_chk.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/vcs_monitor.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/opcfwtmp.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/actions/mailq_pr.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/actions/st_inetd.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/actions/st_syslogd.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/actions/st_mail.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/actions/dist_del.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/cmds/opc_sec_v.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/cmds/opcdf.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/cmds/opclpst.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/cmds/opcps.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/cmds/E10000Log.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/cmds/ssp_config.sh.Z
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/AgentPlatform
/var/opt/OV/share/tmp/OpC_appl/new_syslog/C/TEMPLATES/
LOGFILE/logfile.dat
/var/opt/OV/share/tmp/OpC_appl/new_syslog/C/new_sysl.idx
/var/opt/OV/share/tmp/OpC_appl/new_syslog/ja_JP.SJIS/
TEMPLATES/LOGFILE/logfile.dat
/var/opt/OV/share/tmp/OpC_appl/new_syslog/ja_JP.SJIS/
new_sysl.idx
/opt/OV/OpC/examples/progs/Makef.solaris
/opt/OV/OpC/examples/progs/Makef.solarisdce
what(1) Output:
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/opc_pkg.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/install/opcrclchk:
HP OpenView VantagePoint for Sun Solaris A.06.11 (07
/09/02)
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/install/opcrdschk:
HP OpenView VantagePoint for Sun Solaris A.06.11 (07
/09/02)
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/install/opcrndchk:
HP OpenView VantagePoint for Sun Solaris A.06.11 (07
/09/02)
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/install/opcroschk:
HP OpenView VantagePoint for Sun Solaris A.06.11 (07
/09/02)
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/install/opcrverchk:
HP OpenView VantagePoint for Sun Solaris A.06.11 (07
/09/02)
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/install/opcrinst:
HP OpenView VantagePoint for Sun Solaris A.06.11 (07
/09/02)
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/install/opcnsl:
HP OpenView VantagePoint for Sun Solaris A.06.11 (07
/09/02)
stdio.h 1.39 95/12/04 SMI
feature_tests.h 1.7 94/12/06 SMI
va_list.h 1.6 96/01/26 SMI
types.h 1.38 95/11/14 SMI
isa_defs.h 1.7 94/10/26 SMI
machtypes.h 1.9 94/11/05 SMI
select.h 1.10 92/07/14 SMI
time.h 2.47 95/08/24 SMI
time.h 1.23 95/08/28 SMI
siginfo.h 1.36 95/08/24 SMI
machsig.h 1.10 94/11/05 SMI
socket.h 1.15 95/02/24 SMI
netconfig.h 1.13 95/02/24 SMI
sockio.h 1.11 93/10/26 SMI
ioccom.h 1.10 92/07/14 SMI
in.h 1.4 93/07/06 SMI
stream.h 1.56 94/09/28 SMI
vnode.h 1.54 98/10/09 SMI
t_lock.h 1.42 94/11/02 SMI
machlock.h 1.14 94/10/20 SMI
dki_lkinfo.h 1.8 93/05/03 SMI
dl.h 1.13 93/08/18 SMI
sleepq.h 1.17 94/07/29 SMI
turnstile.h 1.27 94/10/27 SMI
param.h 1.34 95/11/05 SMI
unistd.h 1.24 95/08/24 SMI
pirec.h 1.11 93/12/20 SMI
mutex.h 1.14 94/07/29 SMI
rwlock.h 1.3 94/07/29 SMI
semaphore.h 1.4 94/07/29 SMI
condvar.h 1.6 94/07/29 SMI
cred.h 1.18 94/12/04 SMI
uio.h 1.21 94/04/22 SMI
seg_enum.h 1.1 93/04/03 SMI
poll.h 1.19 94/08/31 SMI
strmdep.h 1.8 92/07/14 SMI
byteorder.h 1.9 94/01/04 SMI
netdb.h 1.17 97/12/23 SMI
types.h 1.38 95/11/14 SMI
feature_tests.h 1.7 94/12/06 SMI
isa_defs.h 1.7 94/10/26 SMI
machtypes.h 1.9 94/11/05 SMI
select.h 1.10 92/07/14 SMI
time.h 2.47 95/08/24 SMI
time.h 1.23 95/08/28 SMI
siginfo.h 1.36 95/08/24 SMI
machsig.h 1.10 94/11/05 SMI
types.h 1.38 95/11/14 SMI
feature_tests.h 1.7 94/12/06 SMI
isa_defs.h 1.7 94/10/26 SMI
machtypes.h 1.9 94/11/05 SMI
select.h 1.10 92/07/14 SMI
time.h 2.47 95/08/24 SMI
time.h 1.23 95/08/28 SMI
siginfo.h 1.36 95/08/24 SMI
machsig.h 1.10 94/11/05 SMI
unistd.h 1.33 95/08/28 SMI
unistd.h 1.24 95/08/24 SMI
utsname.h 1.24 95/07/14 SMI
errno.h 1.13 95/09/10 SMI
errno.h 1.15 95/01/22 SMI
in.h 1.4 93/07/06 SMI
stream.h 1.56 94/09/28 SMI
vnode.h 1.54 98/10/09 SMI
t_lock.h 1.42 94/11/02 SMI
machlock.h 1.14 94/10/20 SMI
dki_lkinfo.h 1.8 93/05/03 SMI
dl.h 1.13 93/08/18 SMI
sleepq.h 1.17 94/07/29 SMI
turnstile.h 1.27 94/10/27 SMI
param.h 1.34 95/11/05 SMI
pirec.h 1.11 93/12/20 SMI
mutex.h 1.14 94/07/29 SMI
rwlock.h 1.3 94/07/29 SMI
semaphore.h 1.4 94/07/29 SMI
condvar.h 1.6 94/07/29 SMI
cred.h 1.18 94/12/04 SMI
uio.h 1.21 94/04/22 SMI
seg_enum.h 1.1 93/04/03 SMI
poll.h 1.19 94/08/31 SMI
strmdep.h 1.8 92/07/14 SMI
byteorder.h 1.9 94/01/04 SMI
socket.h 1.15 95/02/24 SMI
netconfig.h 1.13 95/02/24 SMI
sockio.h 1.11 93/10/26 SMI
ioccom.h 1.10 92/07/14 SMI
netdb.h 1.15 96/05/29 SMI
types.h 1.38 95/11/14 SMI
feature_tests.h 1.7 94/12/06 SMI
isa_defs.h 1.7 94/10/26 SMI
machtypes.h 1.9 94/11/05 SMI
select.h 1.10 92/07/14 SMI
time.h 2.47 95/08/24 SMI
time.h 1.23 95/08/28 SMI
siginfo.h 1.36 95/08/24 SMI
machsig.h 1.10 94/11/05 SMI
unistd.h 1.33 95/08/28 SMI
unistd.h 1.24 95/08/24 SMI
socket.h 1.15 95/02/24 SMI
netconfig.h 1.13 95/02/24 SMI
sockio.h 1.11 93/10/26 SMI
ioccom.h 1.10 92/07/14 SMI
ipc.h 1.15 94/09/03 SMI
un.h 1.8 92/07/14 SMI
netdb.h 1.15 96/05/29 SMI
in.h 1.4 93/07/06 SMI
stream.h 1.56 94/09/28 SMI
vnode.h 1.54 98/10/09 SMI
t_lock.h 1.42 94/11/02 SMI
machlock.h 1.14 94/10/20 SMI
dki_lkinfo.h 1.8 93/05/03 SMI
dl.h 1.13 93/08/18 SMI
sleepq.h 1.17 94/07/29 SMI
turnstile.h 1.27 94/10/27 SMI
param.h 1.34 95/11/05 SMI
pirec.h 1.11 93/12/20 SMI
mutex.h 1.14 94/07/29 SMI
rwlock.h 1.3 94/07/29 SMI
semaphore.h 1.4 94/07/29 SMI
condvar.h 1.6 94/07/29 SMI
cred.h 1.18 94/12/04 SMI
uio.h 1.21 94/04/22 SMI
seg_enum.h 1.1 93/04/03 SMI
poll.h 1.19 94/08/31 SMI
strmdep.h 1.8 92/07/14 SMI
byteorder.h 1.9 94/01/04 SMI
inet.h 1.8 92/07/14 SMI
in_systm.h 1.4 93/02/04 SMI
ip.h 1.4 93/08/18 SMI
ip_icmp.h 1.2 93/02/04 SMI
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/ana_disk.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/cpu_mon.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/disk_mon.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/last_logs.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/mailq_l.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/proc_mon.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/sh_procs.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/swap_mon.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/vp_chk.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/mondbfile.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/dist_mon.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/ssp_chk.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/vcs_monitor.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/monitor/opcfwtmp.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/actions/mailq_pr.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/actions/st_inetd.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/actions/st_syslogd.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/actions/st_mail.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/actions/dist_del.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/cmds/opcdf.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/cmds/opclpst.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/cmds/opcps.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/cmds/E10000Log.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_NCS/cmds/ssp_config.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/opc_pkg.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/install/opcrclchk:
HP OpenView VantagePoint for Sun Solaris A.06.11 (07
/09/02)
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/install/opcrdschk:
HP OpenView VantagePoint for Sun Solaris A.06.11 (07
/09/02)
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/install/opcrndchk:
HP OpenView VantagePoint for Sun Solaris A.06.11 (07
/09/02)
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/install/opcroschk:
HP OpenView VantagePoint for Sun Solaris A.06.11 (07
/09/02)
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/install/opcrverchk:
HP OpenView VantagePoint for Sun Solaris A.06.11 (07
/09/02)
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/install/opcrinst:
HP OpenView VantagePoint for Sun Solaris A.06.11 (07
/09/02)
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/install/opcnsl:
HP OpenView VantagePoint for Sun Solaris A.06.11 (07
/09/02)
stdio.h 1.39 95/12/04 SMI
feature_tests.h 1.7 94/12/06 SMI
va_list.h 1.6 96/01/26 SMI
types.h 1.38 95/11/14 SMI
isa_defs.h 1.7 94/10/26 SMI
machtypes.h 1.9 94/11/05 SMI
select.h 1.10 92/07/14 SMI
time.h 2.47 95/08/24 SMI
time.h 1.23 95/08/28 SMI
siginfo.h 1.36 95/08/24 SMI
machsig.h 1.10 94/11/05 SMI
socket.h 1.15 95/02/24 SMI
netconfig.h 1.13 95/02/24 SMI
sockio.h 1.11 93/10/26 SMI
ioccom.h 1.10 92/07/14 SMI
in.h 1.4 93/07/06 SMI
stream.h 1.56 94/09/28 SMI
vnode.h 1.54 98/10/09 SMI
t_lock.h 1.42 94/11/02 SMI
machlock.h 1.14 94/10/20 SMI
dki_lkinfo.h 1.8 93/05/03 SMI
dl.h 1.13 93/08/18 SMI
sleepq.h 1.17 94/07/29 SMI
turnstile.h 1.27 94/10/27 SMI
param.h 1.34 95/11/05 SMI
unistd.h 1.24 95/08/24 SMI
pirec.h 1.11 93/12/20 SMI
mutex.h 1.14 94/07/29 SMI
rwlock.h 1.3 94/07/29 SMI
semaphore.h 1.4 94/07/29 SMI
condvar.h 1.6 94/07/29 SMI
cred.h 1.18 94/12/04 SMI
uio.h 1.21 94/04/22 SMI
seg_enum.h 1.1 93/04/03 SMI
poll.h 1.19 94/08/31 SMI
strmdep.h 1.8 92/07/14 SMI
byteorder.h 1.9 94/01/04 SMI
netdb.h 1.17 97/12/23 SMI
types.h 1.38 95/11/14 SMI
feature_tests.h 1.7 94/12/06 SMI
isa_defs.h 1.7 94/10/26 SMI
machtypes.h 1.9 94/11/05 SMI
select.h 1.10 92/07/14 SMI
time.h 2.47 95/08/24 SMI
time.h 1.23 95/08/28 SMI
siginfo.h 1.36 95/08/24 SMI
machsig.h 1.10 94/11/05 SMI
types.h 1.38 95/11/14 SMI
feature_tests.h 1.7 94/12/06 SMI
isa_defs.h 1.7 94/10/26 SMI
machtypes.h 1.9 94/11/05 SMI
select.h 1.10 92/07/14 SMI
time.h 2.47 95/08/24 SMI
time.h 1.23 95/08/28 SMI
siginfo.h 1.36 95/08/24 SMI
machsig.h 1.10 94/11/05 SMI
unistd.h 1.33 95/08/28 SMI
unistd.h 1.24 95/08/24 SMI
utsname.h 1.24 95/07/14 SMI
errno.h 1.13 95/09/10 SMI
errno.h 1.15 95/01/22 SMI
in.h 1.4 93/07/06 SMI
stream.h 1.56 94/09/28 SMI
vnode.h 1.54 98/10/09 SMI
t_lock.h 1.42 94/11/02 SMI
machlock.h 1.14 94/10/20 SMI
dki_lkinfo.h 1.8 93/05/03 SMI
dl.h 1.13 93/08/18 SMI
sleepq.h 1.17 94/07/29 SMI
turnstile.h 1.27 94/10/27 SMI
param.h 1.34 95/11/05 SMI
pirec.h 1.11 93/12/20 SMI
mutex.h 1.14 94/07/29 SMI
rwlock.h 1.3 94/07/29 SMI
semaphore.h 1.4 94/07/29 SMI
condvar.h 1.6 94/07/29 SMI
cred.h 1.18 94/12/04 SMI
uio.h 1.21 94/04/22 SMI
seg_enum.h 1.1 93/04/03 SMI
poll.h 1.19 94/08/31 SMI
strmdep.h 1.8 92/07/14 SMI
byteorder.h 1.9 94/01/04 SMI
socket.h 1.15 95/02/24 SMI
netconfig.h 1.13 95/02/24 SMI
sockio.h 1.11 93/10/26 SMI
ioccom.h 1.10 92/07/14 SMI
netdb.h 1.15 96/05/29 SMI
types.h 1.38 95/11/14 SMI
feature_tests.h 1.7 94/12/06 SMI
isa_defs.h 1.7 94/10/26 SMI
machtypes.h 1.9 94/11/05 SMI
select.h 1.10 92/07/14 SMI
time.h 2.47 95/08/24 SMI
time.h 1.23 95/08/28 SMI
siginfo.h 1.36 95/08/24 SMI
machsig.h 1.10 94/11/05 SMI
unistd.h 1.33 95/08/28 SMI
unistd.h 1.24 95/08/24 SMI
socket.h 1.15 95/02/24 SMI
netconfig.h 1.13 95/02/24 SMI
sockio.h 1.11 93/10/26 SMI
ioccom.h 1.10 92/07/14 SMI
ipc.h 1.15 94/09/03 SMI
un.h 1.8 92/07/14 SMI
netdb.h 1.15 96/05/29 SMI
in.h 1.4 93/07/06 SMI
stream.h 1.56 94/09/28 SMI
vnode.h 1.54 98/10/09 SMI
t_lock.h 1.42 94/11/02 SMI
machlock.h 1.14 94/10/20 SMI
dki_lkinfo.h 1.8 93/05/03 SMI
dl.h 1.13 93/08/18 SMI
sleepq.h 1.17 94/07/29 SMI
turnstile.h 1.27 94/10/27 SMI
param.h 1.34 95/11/05 SMI
pirec.h 1.11 93/12/20 SMI
mutex.h 1.14 94/07/29 SMI
rwlock.h 1.3 94/07/29 SMI
semaphore.h 1.4 94/07/29 SMI
condvar.h 1.6 94/07/29 SMI
cred.h 1.18 94/12/04 SMI
uio.h 1.21 94/04/22 SMI
seg_enum.h 1.1 93/04/03 SMI
poll.h 1.19 94/08/31 SMI
strmdep.h 1.8 92/07/14 SMI
byteorder.h 1.9 94/01/04 SMI
inet.h 1.8 92/07/14 SMI
in_systm.h 1.4 93/02/04 SMI
ip.h 1.4 93/08/18 SMI
ip_icmp.h 1.2 93/02/04 SMI
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/ana_disk.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/cpu_mon.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/disk_mon.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/last_logs.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/mailq_l.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/proc_mon.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/sh_procs.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/swap_mon.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/vp_chk.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/mondbfile.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/dist_mon.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/ssp_chk.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/
vcs_monitor.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/monitor/opcfwtmp.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/actions/mailq_pr.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/actions/st_inetd.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/actions/st_syslogd.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/actions/st_mail.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/actions/dist_del.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/cmds/opc_sec_v.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/cmds/opcdf.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/cmds/opclpst.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/cmds/opcps.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/cmds/E10000Log.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/A.06.11/RPC_DCE_TCP/cmds/ssp_config.sh.Z:
None
/var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
solaris/AgentPlatform:
None
/var/opt/OV/share/tmp/OpC_appl/new_syslog/C/TEMPLATES/
LOGFILE/logfile.dat:
None
/var/opt/OV/share/tmp/OpC_appl/new_syslog/C/new_sysl.idx:
None
/var/opt/OV/share/tmp/OpC_appl/new_syslog/ja_JP.SJIS/
TEMPLATES/LOGFILE/logfile.dat:
None
/var/opt/OV/share/tmp/OpC_appl/new_syslog/ja_JP.SJIS/
new_sysl.idx:
None
/opt/OV/OpC/examples/progs/Makef.solaris:
None
/opt/OV/OpC/examples/progs/Makef.solarisdce:
OpC T.02.00 (08/30/93)
cksum(1) Output:
2061327999 4252895 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/opc_pkg.Z
2237779693 28090 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/install/
opcrclchk
3752962863 29760 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/install/
opcrdschk
3442561377 29793 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/install/
opcrndchk
3432754939 6462 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/install/
opcroschk
149297459 28472 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/install/
opcrverchk
991581781 132521 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/install/
opcrinst
4003991183 11164 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/install/
opcnsl
1220754222 2773 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
ana_disk.sh.Z
4280390360 6356 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
cpu_mon.sh.Z
2881416142 6536 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
disk_mon.sh.Z
4229255977 6240 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
last_logs.sh.Z
2408827558 6255 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
mailq_l.sh.Z
3848157904 6370 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
proc_mon.sh.Z
251849355 5868 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
sh_procs.sh.Z
1275846550 6141 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
swap_mon.sh.Z
3108378072 6094 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
vp_chk.sh.Z
851170547 14834 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
mondbfile.sh.Z
1901943676 6495 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
dist_mon.sh.Z
2351147485 6385 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
ssp_chk.sh.Z
2243064473 6975 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
vcs_monitor.sh.Z
3999310668 5520 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
opcfwtmp.Z
3154234756 2567 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/actions/
mailq_pr.sh.Z
166264868 2663 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/actions/
st_inetd.sh.Z
4285343665 2666 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/actions/
st_syslogd.sh.Z
3472746591 2608 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/actions/
st_mail.sh.Z
4194304892 6515 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/actions/
dist_del.sh.Z
682661947 350 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/cmds/
opcdf.Z
2782906264 411 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/cmds/
opclpst.Z
190629175 425 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/cmds/
opcps.Z
867475868 4229 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/cmds/
E10000Log.sh.Z
261739739 4031 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_NCS/cmds/
ssp_config.sh.Z
506459518 6967631 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
opc_pkg.Z
2237779693 28090 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
install/opcrclchk
3752962863 29760 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
install/opcrdschk
3442561377 29793 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
install/opcrndchk
3432754939 6462 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
install/opcroschk
149297459 28472 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
install/opcrverchk
4091915525 132169 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
install/opcrinst
4003991183 11164 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
install/opcnsl
1220754222 2773 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
monitor/ana_disk.sh.Z
4280390360 6356 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
monitor/cpu_mon.sh.Z
2881416142 6536 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
monitor/disk_mon.sh.Z
4229255977 6240 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
monitor/last_logs.sh.Z
2408827558 6255 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
monitor/mailq_l.sh.Z
3848157904 6370 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
monitor/proc_mon.sh.Z
251849355 5868 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
monitor/sh_procs.sh.Z
1275846550 6141 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
monitor/swap_mon.sh.Z
3108378072 6094 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
monitor/vp_chk.sh.Z
851170547 14834 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
monitor/mondbfile.sh.Z
1901943676 6495 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
monitor/dist_mon.sh.Z
2351147485 6385 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
monitor/ssp_chk.sh.Z
2243064473 6975 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
monitor/vcs_monitor.sh.Z
3343981619 20662 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
monitor/opcfwtmp.Z
3154234756 2567 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
actions/mailq_pr.sh.Z
166264868 2663 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
actions/st_inetd.sh.Z
4285343665 2666 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
actions/st_syslogd.sh.Z
3472746591 2608 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
actions/st_mail.sh.Z
4194304892 6515 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
actions/dist_del.sh.Z
2504716616 14033 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/cmds/
opc_sec_v.sh.Z
682661947 350 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/cmds/
opcdf.Z
2782906264 411 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/cmds/
opclpst.Z
190629175 425 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/cmds/
opcps.Z
867475868 4229 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/cmds/
E10000Log.sh.Z
261739739 4031 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/cmds/
ssp_config.sh.Z
2158188735 4368 /var/opt/OV/share/databases/OpC/mgd_node/
vendor/sun/sparc/solaris/AgentPlatform
2950102209 7107 /var/opt/OV/share/tmp/OpC_appl/new_syslog/C/
TEMPLATES/LOGFILE/logfile.dat
675288195 557 /var/opt/OV/share/tmp/OpC_appl/new_syslog/C/
new_sysl.idx
610799592 5231 /var/opt/OV/share/tmp/OpC_appl/new_syslog/
ja_JP.SJIS/TEMPLATES/LOGFILE/logfile.dat
1991845724 553 /var/opt/OV/share/tmp/OpC_appl/new_syslog/
ja_JP.SJIS/new_sysl.idx
1913040897 1058 /opt/OV/OpC/examples/progs/Makef.solaris
4262292733 1239 /opt/OV/OpC/examples/progs/Makef.solarisdce
Patch Conflicts: None
Patch Dependencies: None
Hardware Dependencies: None
Other Dependencies: None
Supersedes:
PHSS_22255 PHSS_22885 PHSS_23824
Equivalent Patches:
ITOSOL_00158:
sparcSOL: 2.6 2.7 2.8
PHSS_27298:
s700: 11.00
s800: 11.00
Patch Package Size: 11950 KBytes
Installation Instructions:
Please review all instructions and the Hewlett-Packard
SupportLine User Guide or your Hewlett-Packard support terms
and conditions for precautions, scope of license,
restrictions, and, limitation of liability and warranties,
before installing this patch.
------------------------------------------------------------
1. Back up your system before installing a patch.
2. Login as root.
3. Copy the patch to the /tmp directory.
4. Move to the /tmp directory and unshar the patch:
cd /tmp
sh PHSS_27297
5a. For a standalone system, run swinstall to install the
patch:
swinstall -x autoreboot=true -x match_target=true \
-s /tmp/PHSS_27297.depot
By default swinstall will archive the original software in
/var/adm/sw/patch/PHSS_27297. If you do not wish to retain a
copy of the original software, you can create an empty file
named /var/adm/sw/patch/PATCH_NOSAVE.
WARNING: If this file exists when a patch is installed, the
patch cannot be deinstalled. Please be careful
when using this feature.
It is recommended that you move the PHSS_27297.text file to
/var/adm/sw/patch for future reference.
To put this patch on a magnetic tape and install from the
tape drive, use the command:
dd if=/tmp/PHSS_27297.depot of=/dev/rmt/0m bs=2k
Special Installation Instructions:
NOTE: This patch contains an updated "Syslog (Solaris)"
template. If you want to update the template in your
DB, please enter:
# opccfgupld -add -subentity new_syslog
This will add the new conditions to the
"Syslog (Solaris)" template.
In the Admin GUI you can now remove the template
"Kernel Logs (Solaris)" as the conditions from the
default template "Kernel Logs (Solaris)" have been
added to the template "Syslog (Solaris)". If you have
modified the default "Kernel Logs (Solaris)" template
you might want to compare the "Syslog" and the
"Kernel Logs" template and decide whether you still
need the "Kernel Logs" template or not.
(A) Patch Installation Instructions
-------------------------------
(A1) Install the patch, following the standard installation
instructions provided above under "Installation
Instructions".
Observe that you can use opc_backup(5) for backing up
your system before installing a patch.
NOTE: Make sure that no agent of the platform
addressed by this patch is distributed (either
from the ITO Administrator's GUI or from command
line using inst.sh) while running swremove.
If you are running VPO in a MC/ServiceGuard
installation:
- Note, that only files on the shared disk volume
at /var/opt/OV/share will be patched. Therefore
install the patch on one cluster node while the
shared disks are mounted. The server processes
may be running during patch installation.
- It is not necessary to install this patch on all
cluster nodes. Even if the software inventory on
the other cluster nodes will not be updated, the
patched files will be available there when the
shared disk is switched to them.
NOTE: This patch must be installed on the VPO Management
Server system, NOT on an VPO Managed Node directly.
Changes will take effect on managed nodes by means of
VPO Software Distribution (using 'Force Update' if
there is already an agent installed on the managed
node). See chapter 2 of the VPO Administrator's
Reference manual for more information.
(B) Patch Deinstallation Instructions
---------------------------------
NOTE: Make sure that no agent of the platform
addressed by this patch is distributed (either
from the ITO Administrator's GUI or from
command line using inst.sh) while running
swremove.
If you are running VPO in a MC/ServiceGuard
installation make sure to mount the shared
disks at the node and only at the node that
had them mounted during patch installation.
Otherwise restoration of the original files
onto the shared disk will fail.
-----End of Document ID: PHSS_27297------------------------------------------
Document ID: PHSS_28570
Date Loaded: 20030402
Title: s700_800 10.X OV OB3.50 patch - CORE packet
Patch Name: PHSS_28570
Patch Description: s700_800 10.X OV OB3.50 patch - CORE packet
Creation Date: 03/03/31
Post Date: 03/04/02
Hardware Platforms - OS Releases:
s700: 10.00 10.01 10.10 10.20
s800: 10.00 10.01 10.10 10.20
Products:
OmniBackII A.03.50
Filesets:
OMNIBACK-II.OMNI-CORE-IS,A.03.50
OMNIBACK-II.OMNI-CORE,A.03.50
Automatic Reboot?: No
Status: General Release
Critical: No
Path Name: /hp-ux_patches/s700_800/10.X/PHSS_28570
Symptoms:
PHSS_28570:
Id = HSLco39544 SR:H555009435
Restore session on HP-UX with VXFS 3 reports error:
"Cannot restore ACLs"
for every file restored.
Id = HSLco40537 SR:H555009863
When backing up very large SAP databases with SSEA
split mirror, backups can fail with error:
"BR280I Time stamp <time>
BR296I Split of mirror disks successful
BR274E File /<sapdata_path>/system.data1 not found"
PHSS_27589:
Id = HSLco37266 SR: H555008830
CORE patch breaks Oracle8 Integration functionality.
PHSS_25819:
Id = HSLco20414 SR: H555003134
Device maintenance from command line is not sufficient.
Id = HSLco27521 SR: H555005696
During scheduled purge error message is displayed:
"Bad catalog access for message #3137 in set 11".
Id = HSLco27649 SR: H555005721
Upgrade of AIX client fails with error:
"Unexpected untar problem".
Id = HSLco31142 SR: H555006771
Load balancing is not working properly.
Id = JAGad96899 SR: 8606227839
Omniback II does not support Ext3 filesystem on
Linux systems.
PHSS_24429:
Id = HSLco27823
OmniBack II does not recognize Reiser filesystem on
Linux.
Id = HSLco26064
Installation of OmniBack II clients on Linux 7.x
systems does not complete.
PHSS_23687:
Id = NSMbb37117
util_oracle8.exe complains that Oracle is not linked
with OmniBack II for backup.
Id = NSMex03956
".util ISINFO" returns corrupted bytes_to_be_received
size.
Id = HSLco23481
Installation on HP-UX 11.20 systems does not complete.
PHSS_22914:
Id = NSMex03937
User can gain an unauthorized access to an OmniBack
client.
Id = NSMex03757, NSMex03667
Backup of one object fails with:
"IPC Read Error. Connection reset by peer".
PHSS_22434:
Id = NSMex03372
A backup of 129 Sybase databases fails with
"[61:1005] Got unexpected close from INET on
<hostname>.".
Id = NSMex03638 SR: B554000768
Omnidbutil's option "-change_objname" does not work
properly.
"[61:1005] Got unexpected close from INET on
<hostname>.".
Defect Description:
PHSS_28570:
Id = HSLco39544
If files are backed up on JFS filesystem and restored
to VXFS filesystem, minor error is reported for every
file restored.
Resolution:
Message "Destination file system does not support ACLs!"
is added and is reported only once, subsequent error
messages are suppressed.
Id = HSLco40537
In split mirror environment with very large SAP
databases, it can happen that the size of the message
buffer that OmniBack II uses is too small to fit in
for the complete list of SAP files to be backed up.
Resolution:
New environment variable is introduced: OB2IPCBUFSIZE.
In order to solve this problem, the buffer size can
be increased by setting the OB2IPCBUFSIZE environment
variable in the .omnirc file on CM, R1 and R2 hosts,
specifying the desired amount of memory to be used
for the buffer.
PHSS_27589:
Id = HSLco37266 SR: H555008830
Omniback Core patch packets erroneously contain an
outdated version of the libob2oracle8(_64bit).sl
library.
As a result, the correct version of this library
is always overwritten by the old version when the
Core patch is applied or another OmniBack II agent is
installed on the Oracle8 system.
Resolution:
libob2oracle8(_64bit).sl is removed from the CORE
package.
PHSS_25819:
Id = HSLco20414
Device enabling, disabling and status report can not be
performed using OmniBack II command line.
Reslution:
New options "-disable_device", "-enable_device" and
"-device" are added to omnimm, omniupload and
omnidownload. The appropriate messages are added to
catalog.
Part of SSPUX350_038.
Id = HSLco27521
The message 3137 is not defined in the catalog.
Resolution:
The appropriate message is added to catalog.
Id = HSLco27649
Shared libraries libdc and libde have to be removed
before upgrade of AIX clients. Due to changes in
OmniBack II linking process, extensions for the
libraries are changed, so the libraries are not
removed during the installation.
Resolution:
Correct shared libraries are removed during the
upgrade process.
Id = HSLco31142
There is no warning reported when one creates a datalist
or a barlist with load balancing enabled and minimum
number of devices greater than number of configured
logical devices.
Resolution:
Comparison of minimum and configured devices number
is implemented and appropriate warning message is added
to catalog.
Id = JAGad96899
Omniback II does not support Ext3 filesystem on
Linux systems.
Resolution:
Omniback II supports Ext3 filesystem on Linux systems.
Part of SSPUX350_065.
PHSS_24429:
Id = HSLco27823
OmniBack II does not recognize Reiser filesystem om
Linux systems.
Resolution:
OmniBack II recognizes Reiser filesystem.
Id = HSLco26064
OmniBack II client installation on Linux 7.x does not
complete because of missing entries in /etc/xinetd.conf
file.
Resolution:
Proper entries are added to /etc/xinetd.conf file
during the installation of OmniBack II client on a
Linux 7.x system.
PHSS_23687:
Id = NSMbb37117
Library $ORACLE_HOME/lib/libobk.so is not properly
linked and the error message is incorrect.
Resolution:
A proper message is added to message catalog.
Id = NSMex03956
Logging messages redirection does not work properly.
Resolution:
Exporting VUE variable is added.
Id = HSLco23481
Installation on HP-UX 11.20 systems does not complete.
Resolution:
Installation on HP-UX 11.20 systems completes.
PHSS_22914:
Id = NSMex03937
User can gain access to an OmniBack client.
Resolution:
Code is changed.
To preserve the previous behaviour, a variable must
be set in the /opt/omni/.omnirc file (not recommended):
OB2INETSECUEREXEC = 1
Part of SSPUX350_022.
Id = NSMex03757, NSMex03667
Inet times out during the export of variables.
Resolution:
Environment variable OB2INETTIMEOUT is introduced. It
should be set in /opt/omni/.omnirc file in form
OB2INETTIMEOUT=<time_in_seconds>
where time_in_seconds is timeout period for inet.
Recommended value is 150.
Part of SSPUX350_023.
PHSS_22434:
Id = NSMex03372
Backup fails if there are more than 256 objects in a
single barlist.
Resolution:
Number of objects in a barlist increased to 1024.
Id = NSMex03638
Omnidbutil's option "-change_objname" should not be a
part of OmniBack II A.03.50.
Resolution:
Option "-change_objname" is removed.
SR:
H555009863 H555009435 B554000887 B554000797 H555008830
H555005696 H555003134 8606227839 H555006771 H555005721
H555005779 H555005136 H555003879 H555004628 B555007579
B554000503 B554000768
Patch Files:
/opt/omni/databases/vendor/omnicf/hp/s800/hp-ux-1020/
A.03.50/packet.Z
/opt/omni/databases/vendor/omnicf/hp/s800/hp-ux-10/A.03.50/
packet.Z
/opt/omni/databases/vendor/omnicf/hp/s800/hp-ux-11/A.03.50/
packet.Z
/opt/omni/databases/vendor/omnicf/dec/alpha/osf1-4/A.03.50/
packet.Z
/opt/omni/databases/vendor/omnicf/gpl/i386/linux/A.03.50/
packet.Z
/opt/omni/databases/vendor/omnicf/ibm/rs6000/aix-42/A.03.50/