OSEC

Neohapsis is currently accepting applications for employment. For more information, please visit our website www.neohapsis.com or email hr@neohapsis.com
 
HP-UX series 700 10.X patch digest

From: IT Resource Center (support_feedbackus-support2-mail.external.hp.com)
Date: Sun Apr 06 2003 - 22:54:49 CDT


                        HP Support Information Digests

===============================================================================
o IT Resource Center World Wide Web Service
   ---------------------------------------------------

   If you subscribed through the IT Resource Center and would
   like to be REMOVED from this mailing list, access the
   IT Resource Center on the World Wide Web at:

     http://support.itrc.hp.com/

   Login using your IT Resource Center User ID and Password.
   Then select Support Information Digests (located under
   Maintenance and Support). You may then unsubscribe from the
   appropriate digest.

   To download a patch referenced below, access the
   IT Resource Center on the World Wide Web at:

     http://support.itrc.hp.com/

   Login using your IT Resource Center User ID and Password.
   Then select Individual Patches (under Maintenance and Support)
   to access the patch. You may also download a patch via anonymous
   ftp(1) from ftp.itrc.hp.com.
===============================================================================


Digest Name: weekly HP-UX series 700 10.X patch digest
    Created: Sun Apr 6 6:05:44 EDT 2003

Table of Contents:

Document ID Title
--------------- -----------
PHSS_28727 s700_800 10.X OV OB3.50 patch - CS packet
PHSS_28725 s700_800 10.X OV OB3.50 patch - CC packet
PHSS_28723 s700_800 10.20 OV OB4.10 patch - SAP packet
PHSS_28578 s700_800 10.X OV OB3.50 patch - SSEA packet
PHSS_27297 s700_800 10.20 OV ITO6.0X Solaris Agent Patch A.06.11
PHSS_28570 s700_800 10.X OV OB3.50 patch - CORE packet
PHSS_28887 s700 10.26 Multimedia patch

The documents are listed below.
-------------------------------------------------------------------------------


Document ID: PHSS_28727
Date Loaded: 20030404
      Title: s700_800 10.X OV OB3.50 patch - CS packet

Patch Name: PHSS_28727

Patch Description: s700_800 10.X OV OB3.50 patch - CS packet

Creation Date: 03/03/27

Post Date: 03/04/04

Hardware Platforms - OS Releases:
        s700: 10.00 10.01 10.10 10.20
        s800: 10.00 10.01 10.10 10.20

Products:
        OmniBackII A.03.50

Filesets:
        OMNIBACK-II.OMNI-CS,A.03.50

Automatic Reboot?: No

Status: General Release

Critical: No

Path Name: /hp-ux_patches/s700_800/10.X/PHSS_28727

Symptoms:
        PHSS_28727:
        Id = HSLco39169 SR:H555009297
            After aborting host backup the object post exec script
            does not execute.

        Id = HSLco39878 SR:H555009560
            Backup run twice when daylight saving time is changed.

        Id = HSLco40494 SR:H555009843
            While backup with reconnect option is in progress and
            BSM loses connection to monitor the message appears:

              "[Warning] From: BSM<host> "<device>" Time: <time>
               [61:2013] Some of the backup devices are occupied.
               Session is waiting for all the devices to get free.

               [Major] From: BSM<host> "<device>" Time: <time>
               [61:3003] Lost connection to Monitor named "noname"
                 on host <host>.
               Ipc subsystem reports: "IPC Read Error
               System error: [232] Connection reset by peer"

        Id = HSLco40537 SR:H555009863
            When backing up very large SAP databases with SSEA
            split mirror, backups can fail with error:

              "BR280I Time stamp <time>
               BR296I Split of mirror disks successful
               BR274E File /<sapdata_path>/system.data1 not found"

        PHSS_28021:
        Id = HSLco35783 SR: H555008533
            Informix backup hangs if a resource type is backed up
            to a different device than the other resource types.

        Id = HSLco36721 SR: H555008690
            If a Manager-of-Managers Server is also a
            MC/ServiceGuard virtual node, then the command:
            "omnirpt -report list_sessions -timeframe
             <start_hours_ago><hours_duration>
             -multicell -no_multiple"
            lists the matching sessions from this node twice.

        Id = HSLco37099 SR: H555008780
            Queries from client Cell Server in MoM environment
            with CMMDB fail with:

             "[12:1012] Cannot access the file."

        Id = HSLco37193 SR: H555008807
            When backing up SAP integration with EMC split mirror
            functionality, not all the SAP files are backed up.

        Id = HSLco37276 SR: H555008832
            OmniBack internal database backup fails with an error:

            "[Major] From: BSM<computer> "<object>" Time: <time>
             [61:3003] Lost connection to VBDA named <object>
                on host <host>.
                Ipc subsystem reports: "IPC Read Error
                System error: [232] Connection reset by peer"

        Id = HSLco37939 SR: H555008927
            While configuring OmniBack II reports using GUI, only
            datalists are listed (barlists are missing).

        Id = HSLco37723 SR: H555008892
            When performing omnimlist -catalog on media, the
            program exits and debug.log contains this
            Interprocess Communication error:

            08/06/02 11:13:15 OMNIMLIST.1224.0
            ["/src/lib/ipc/ipc.c /main/r31_split/16":3434]
            A.03.50 b216
            [ipc_receiveDataEx] buffer 102400 bytes to
            small to receive data 258487 bytes => ignored

        PHSS_26889:
        Id = HSLco35076 SR: H555008261
            Backup fails with an error:

              "Internal error. Allocation from library failed.
               The Media Management daemon reports:
                  Internal error: DbaXXXX functions."

        Id = HSLco35364 SR: H555008410
            The earlier Patch PHSS_26348 introduced behavior
            that can cause database integration
            (for example Oracle or SAP) backups to fail.
            With PHSS_26348 installed, OmniBack does not properly
            lock the logical devices to prevent concurrent access
            by multiple sessions. As a result, database integration
            backups may fail instead of waiting for the device
            to become free.

        Id = HSLco35515 SR: H555008452
            Backup Session Manager does not terminate after
            the time specified in the SmDaIdleTimeout variable
            when connection to Disk Agent and Media Agent is lost.

        Id = JAGae27169 SR: 8606262839
            Configuration report shows an incorrect list of
            scheduled backups.

        PHSS_26347:
        Id = HSLco20414 SR: H555003134
            Device maintenance from command line is not sufficient.

        Id = HSLco31865 SR: H555006924
            The message for the mount request is not in proper
            format when forwarded to ITO.

        Id = HSLco32789 SR: H555007191
            If pre-exec script does not complete in
            ScriptOutputTimeout time (default 15 minutes), Backup
            Session Manager lopps and can not be aborted.

        Id = JAGad90905 SR: 8606221771
            Case sensitive search does not work.

        Id = JAGae05208 SR: 8606236143
            Not all session manager processes are correctly stopped
            using csailover.ksh script.

        Id = HSLco33360 SR: H555007428
            Backup fails with error:

              "[Major] From: BMA<HOST> Time:<TIME>
               [90:64] Can not unload exchanger medium
                     (Storage slot is occupied.)".

        Id = JAGae14881 SR: 8606248483
            Address of a Cell Console client is incorrectly
            handled.

        Id = HSLco34255 SR: H555007796
            omnirpt failes after the installation of
            PHSS_25002/25003.

        PHSS_25002:
        Id = HSLco24755 SR: B555011718
            OmniBack II issues a mount request for tape during
            the restore session.

        Id = HSLco28232 SR: H555005922
            Backup is waiting for all pre/post-exec scripts to
            finish before proceeding.

        Id = HSLco28279 SR: H555005975
            Purge of filenames aborts daily.

        Id = HSLco29098 SR: H555006248
            Restore session fails with error:

              "Can not load exchanger medium.".

        Id = HSLco30814 SR: H555006710
            Session ends as 'Failed' because OmniBack II tries
            to back up non existent SAP redo logs.

        Id = HSLco31142 SR: H555006771
            Load balancing is not working properly.

        Id = HSLco31295 SR: H555006799
            OmniBack reports that medium copy session finished
            successfully although it failed.

        Id = HSLco31325 SR: H555006810
            When OmniBack II Integration backup is aborted,
            another complete sesson starts and finishes backup of
            remaining database objects.

        Id = JAGad86475 SR: 8606217323
            Cell Request Server and session managers frequently
            abort.

        PHSS_24658:
        Id = JAGad48558
             OmniBack II creates duplicated tape labels.

        Id = JAGad64442
             OmniBack II internal database owner is not
             properly set after configuring OmniBack II in
             MC/ServiceGuard environment.

        Id = NSMex03907
            Browsing of a filesystem in Restore GUI sometimes
            fails with an error:

              "Cannot browse from root. Please specify
               starting point.".

        Id = NSMex04086
            Session status is "Completed/Failures" although there
            is no indication of errors.

        Id = NSMex04149
            If Cell Request Service (CRS) is restarted in cluster
            aware mode, error:

              "-2 starting omnidbutil -clear!"

            occurs in cluster.log file.

        Id = NSMex04164
            Omnitrig fails with an error:

              "Error parsing schedule purge_schedule.".

        Id = NSMex04283
            Adding OmniBack II licenses in MC/ServiceGuard
            environment fails with an error:

              "Cell Server host IP is not in IP range.".

        Id = NSMex04287
            Load balancing uses less devices than expected.

        Id = NSMex04319
            OmniBack II issues mount request, but it can not be
            confirmed because the tape drive is busy.

        Id = NSMex04311
            Post-exec script specified for a virtual hostname does
            not start if pre-exec script fails.

        Id = NSMex04403
            Tape import is reported successful although it is not.

        Id = NSMex04540
            Restore session fails with error:

              "Can not load exchanger medium.".

        PHSS_23470:
        Id = JAGad36093
            Session status indicates "Completed" although one of the
            agents failed.

        Id = NSMbb37729
            Devbra reports:

              "[90:11] Unrecognized option "/" => ignored".

        Id = NSMex03425
            Backup of SAP archive logs fails with:

              "[Major] From: OB2BAR<hostname> <ORASID> Time:<time>
                   Can not read BSM message (IPC Read Error
                   System error: [232] Connection reset by peer.)".

        Id = NSMex03621
            Restore does not work correctly after the mount
            request confirmation.

        Id = NSMex03701
            OmniBack Session Report contains many

              "[Warning] From: BSM<hostname> <DBNAME> Time:<time>
                 Received connect from BAR Backup DA on host <host>
                 that is not specified in CLIENT statement in the
                 barlist."

            warning messages.

        Id = NSMex03711
            Error:

              "Hostname is not in IP range."

            is reported after service guard fails over to a
            secondary host.

        Id = NSMex03739
            Pre- and post-exec scripts return invalid exit status.

        Id = NSMex03847
            After upgrade to OmniBack II 3.50, backup to STK 9840
            device fails with an error:

              "Invalid physical device type => aborting."

        Id = NSMex03894
            Host backup fails if host has more than 600
            mountpoints.

        Id = NSMex03910
            If Sybase backup fails before OB2BAR is started,
            a Major message is reported in the session output,
            but session status is "Completed".

        Id = NSMex03917
            Objects are lost from OmniBack II internal database
            after the execution of "omnidbutil -cdbsync" command.

        Id = NSMex03991
            Full Oracle backup can be appended to a medium in a
            pool with "append incremental only" property.

        Id = NSMbb38972
            MS Exchange 2000 scheduled backups do not start.

        Id = NSMex03246
            Backup Session Manager is sending wrong SNMP messages to
            ITO Management server.

        Id = NSMex04159
            When restarting failed sessions multiple sessions are
            created.

        Id = NSMex04261
            Import of session fails.

        PHSS_23105:
        Id = NSMex03757
            Bad backup performance after upgrade from OmniBack II
            2.55 or 3.00.

        Id = NSMex03977
            Execution of command

              "omnirpt -report used_media -timeframe <t1> <t2>"

            results in the following error message:

              "DB[4] internal error [-16] record not connected
               to set".
              "DB[4] internal error [-16] record not connected
               to set".

        PHSS_22369:
        Id = JAGad13634
            Informix barlists are not converted into a OmniBack II
            3.50 format after an upgrade from OmniBack II 2.55.

        Id = JAGad17029
            "List from media" ignores "See private objects" option.

        Id = NSMex03356
            Permanent license shows up as out of IP range.

        Id = NSMex03365
            Backup session is not logged in the database if file
            pattern search is performed in parallel.

        Id = NSMex03419
            After importing a tape from 2.55 to 3.x cell some of
            the files can not be restored.

        Id = NSMex03466
            After the upgrade from OmniBack II 3.00 to 3.50, a
            warning

              "Received connect from BAR backup DA on host
               <hostname> that is not specified in CLIENT statement
               in barlist."

            appears on a client with multiple lan cards.

        Id = NSMex03481
            A backup of MC/SG can not be aborted after the switch.

        Id = NSMex03491, JAGad28516
            Directories are backed up even if excluded in host
            backup.

        Id = NSMex03493
            Omnitrig does not pass debugging parameters to omnirpt.

        Id = NSMex03583, NSMex03631
            OmniBack II ignores the tape loaded after the mount
            request for SCSI-II changer device.

        Id = NSMex03638 SR: B554000768
            Option "-change_objname" does not work properly.

        Id = NSMex03501
            List of media fails with an error:

              "Medium details not available.
               Medium owned by Cell Manager: <hostname>."

        Id = NSMex03683
            Copy session of write-protected tape is aborted and
            cleaning tape is requested in the source tape drive.

        Id = NSMex02584
            Internal database server (RDS) abnormally ends due to
            lack of memory.

        Id = NSMex03702
            Internal database server (RDS) abnormally ends during
            a SAP restore.

        Id = NSMex03289
            Sessions are disappearing from OmniBack II database.

        Id = NSMex03521
            OmniBack II database gets corrupted.

        Id = NSMex03737
            Sessions are disappearing from OmniBack II database.

        Id = NSMex03758, NSMex03759, NSMex03646
            Execution of commands "omnidb -session <sess_id>" and
            "omnirpt -report used_media -timeframe <n> <n>"
            reports that the database is corrupt, but omnidbcheck
            reports no problem.

Defect Description:
        PHSS_28727:
        Id = HSLco39169 SR:H555009297
            Before executing the object post-exec script,
            OmniBack II checks if session is aborting.
            If it is, then script does not execute.

        Resolution:
            Global variable PostExecOnAbortHostBackup was added.
            If this global variable is set to 1, the post-exec
            script will execute even if the session is aborting.

        Id = HSLco39878 SR:H555009560
            The algorithm, that handles the daylight saving time
            changes is incomplete.

        Resolution:
            The algorithm is changed for both time changes:
            02h->03h and 03h->02h.

        Id = HSLco40494 SR:H555009843
            If BSM loses connection to monitor message appears.
            The problem (reconnect) should only be reported
            for agents (DA, MA...).

        Resolution:
            The function is modified to check if the connection
            with the agent (DA, MA ...) is broken. If BSM loses
            connection to monitor, no messages are displayed.

            Part of SSPUX350_089.

        Id = HSLco40537 SR:H555009863
            In split mirror environment with very large SAP
            databases, it can happen that the size of the message
            buffer that OmniBack II uses is too small to fit in
            for the complete list of SAP files to be backed up.

        Resolution:
            New environment variable is introduced: OB2IPCBUFSIZE.
            In order to solve this problem, the buffer size can
            be increased by setting the OB2IPCBUFSIZE environment
            variable in the .omnirc file on CM, R1 and R2 hosts,
            specifying the desired amount of memory to be used
            for the buffer.

            For determining buffer size please see the Resolution
            of Id = HSLco37193 below.

            Part of SSPUX350_088.

        PHSS_28021:
        Id = HSLco35783
            With Informix integration backup, it is possible to
            specify which resource type will be backed up by which
            device. If most of the resource types are backed up to
            n devices, but the L (Log) resource type is backed up
            to a separate, additional device, and load balancing
            is set to (max=n, min=n), then the session will hang
            because it tries to lock n+1 devices for all the
            resource type backups.

        Resolution:
            OmniBack now unlocks devices, if they were not used for
            any backup for a certain amount of time. It also stops
            media agents that have not had any backup agents
            assigned to them for the timeout period. With both
            changes (unlock device, stop media agent), it can start
            new media agents, required by specific resource type
            backup agents that have already contacted Backup Session
            Manager.

            Important note:
            ---------------
            In order to get the session running, there are some
            timeout parameters (global options) that have to be
            properly set :

            Global options
            --------------
            A - BackupDeviceIdle
            B - SmPeerID
            C - SmDaIdleTimeOut
            D - SmMaIdleTimeOut

            Conditions that have to be satisfied :
            -----------
            A<B
            C<D

            Example:

                    Default Suggested
                    value value
            -----------------------------------
            A 10min 4min
            B 5min 5min
            C 120min 120min
            D 140min 140min

            Explanation:
            ------------
            [A<B]
            After all BAR clients stop sending data to a device,
            the BSM waits for either A or B timeout to happen for
            the device. If the timeout A is reached, the backup
            device will be stopped gracefully, if B timeout is
            reached, it will be aborted. That's why it is important
            that the condition A<B is fulfilled.

            [C<D]
            This is a general condition that must be met for all MA
            and DA processes, and is stated in the global options
            file.

            It is important to keep the option BackupDeviceIdle
            under 300 seconds (5 minutes). If 300 or higher, the
            session behavior will be unpredictable (errors are
            likely to appear).

            Part of SSPUX350_087.

        Id = HSLco36721
            When running "omnirpt" command all the cell servers from
            the "mom_info" and the local Cell Server are queried for
            matching sessions. The virtual node and the local host
            are actually the same machine, so the matching sessions
            are listed twice.

        Resolution:
            The function gethostname() is not used any more to
            determine if the inspected host is also the local host,
            because in case of a Manager-of-Managers/ServiceGuard
            environment it returns the physical node hostname and
            not the virtual node hostname, making the virtual
            hostname being seen as a non-local host. In this way
            the virtual hostname is not queried for matching
            sessions any more.

        Id = HSLco37099
            Format of messages is changed from buffer to pointer
            but change is not implemented in all areas. Database
            Session Manager gets message from MoM server in
            improper format and closes the connection.

        Resolution:
            Size of message is dynamically changed, messages are
            not send in fixed size anymore.

        Id = HSLco37193
            In split mirror environment with huge SAP databases
            it can happen that the size of the message buffer
            OmniBack II uses is too small to receive complete list
            of SAP files to be backed up.

        Resolution:
            Setting the OB2IPCBUFSIZE environment variable in the
            /opt/omni/.omnirc file on Cell Server, R1 and R2 hosts,
            specifying the desired amount of memory to be used for
            the buffer solves the described problem.
            Please read the following instructions and make sure
            that the patches listed in "Other Dependencies" section
            (see below) are installed and the environment
            variable is set on Cell Server, R1 and R2 systems before
            running the backup!

            How to determine the buffer size?
            ---------------------------------

            N_obj: number of objects (files)
            N_fs: number of file systems
            N_lvmvg: number of volume groups
            N_dg: number of disk groups
            N_rdsk: number of rawdisks
            Obj: Object Name
            ObjBack: Object Backup Name
            MntPathLen: Path name on backup (R2) host
                         (example: /var/opt/omni/tmp/App_host)
            fsmnt: File System Mount Point
            fsdev: File System Device File
                         (example: /dev/dsk/[c0t1d1,lvol1])
            vg: Volume group
                         (ex: /dev/vg01)
            dg: Disk group (VxVM) - dependence on mapfile
                         which is required for creating disk group
                         (example:/dev/vx/dsk/dg01)
            rdsk: Raw disk file name
                         (example: /dev/rdsk/c1t1d1)
            AvgLen_<xxx> average length of <xxx>

            There are two different buffers used:

            1. BSM <-> R1
            2. R1 <-> R2

            Calculating the BSM <-> R1 buffer size
            --------------------------------------
            MsgSize_BSM_R1 = N_obj * (AvgLen_Obj + 1 + MntPathLen)

            Calculating the R1 <-> R2 buffer size
            -------------------------------------
            MsgSize_R1_R2 =
              N_obj*(AvgLen_Obj+1+AvgLen_ObjBack) +
              N_fs*(AvgLen_fsmnt*2 + MntPathLen + AvgLen_fsdev*2)+
              N_lvmvg*(AvgLen_vg*2) + N_dg*(AvgLen_dg*2) +
              N_rdsk*(AvgLen_rdsk*2)

            Calculating the OB2IPCBUFSIZE value
            -----------------------------------
            OB2IPCBUFSIZE > max (MsgSize_BSM_R1, MsgSize_R1_R2)

            RESTORE NOTE:
            -------------
            If restore is started using the sapbda utility,
            the variable OB2IPCBUFSIZE must be exported to
            environment prior to starting sapbda.

            Known problems:
            ---------------
            If the calculated variable OB2IPCBUFSIZE is correctly
            set, but is still too small for the file list to fit
            into the message buffer, the session will fail with
            the following error seen in the report:

            BR295I Splitting mirror disks...
            BR280I Time stamp <time>
            BR279E Return code from '/opt/omni/lbin/ob2smbsplit
               /<sap_homedir_path>/.<filename>.lst': 2
            BR299E Split/resynchronization of mirror disks failed

            In this case the variable OB2IPCBUFSIZE must be
            recalculated to appropriate value. See above how to
            determine it.

            Part of SSPUX350_080.

        Id = HSLco37276
            Last message from Disk Agent is sometimes lost. This
            causes Disk Agent's status reported as "Failed".

        Resolution:
            New OmniBack II environment variable:
              OB2VBDASLEEPBEFORECLOSE
            is introduced.
            Its default value is 0. Setting it to a positive
            number, in /<OMNIBACK_HOME>/.omnirc file, it specifies
            number of seconds to pass before Disk Agent completes
            after sending the last block of data.
            Sleep time insignificantly influences backup
            performance.

        Id = HSLco37939
            Barlists are members of a group which is not displayed
            under reporting group in GUI Reporting.

        Resolution:
            Barlists are moved to a group that is displayed in GUI.

        Id = HSLco37723
            Media handling results in IPC error when the buffer
            size is increased and variable OB2IPCBUFSIZE is set as
            described in above Resolution for problem HSLco37193.

        Resolution:
            Media Session Manager is rebuilt in order to properly
            include the changes introduced with Resolution for
            HSLco37193.

            Part of SSPUX350_085.

        PHSS_26889:
        Id = HSLco35076
            In case of Media Management Database corruption
            backup can fail due to problems with the media
            allocation.

        Resolution:
            Media allocation is improved.

            Part of SSPUX350_066.

        Id = HSLco35364
            Two or more integration backup sessions using the same
            device do not queue for backup, but they all try to use
            this device at the same time. This results in media
            agent failure. During integration backup device
            should be locked for backup, but other sessions
            can still use it.

        Resolution:
            Backup Session Manager correctly locks the device(s),
            and other sessions wait in the queue for backup until
            the device is free.

            Part of SSPUX350_077.

        Id = HSLco35515
            In some cases because of incorrect agent exit code
            Backup Session Manager does not terminate other agents
            in correct order, which results in Backup Session
            Manager hang.

        Resolution:
            The exit code is changed.

            Part of SSPUX350_076.

        Id = JAGae27169
            Database session manager compares days, not taking
            into account 15 minute units. Therefore report shows
            some additional backups, which are scheduled past
            the specified time frame.

        Resolution:
            Beside days Database Session Manager compares 15
            minute units.

        PHSS_26347:
        Id = HSLco20414
            Device enabling, disabling and status report cannot be
            performed using OmniBack II command line.

        Resolution:
            New options "-disable_device", "-enable_device" and
            "-device" are added to omnimm, omniupload and
            omnidownload.

            Part of SSPUX350_038.

        Id = HSLco31865
            The message is not properly filtered out.

        Resolution:
            The message is properly filtered before it is send
            to ITO.

        Id = HSLco32789
            Improper implementation of object assigning to Media
            Agent causes Backup Session Manager to loop forever.

        Resolution:
            Object assignment to Media Agent is corrected.

        Id = JAGad90905
            Flag for case sensitivity is not checked before
            search session is executed.

        Resolution:
            Case sensitivity flag is always checked.

        Id = JAGae05208
            The regular expression that is parsed by the awk script
            does not return the process ID (PID) which should be
            killed.

        Resolution:
            Regular expression string in awk parse command is
            changed.

        Id = HSLco33360
            Executing an "enter" operation for the slot being
            used for backup results in backup failure.

        Resolution:
            New global option EnterEjectCheckLocking is
            introduced. If this option is set, Media Management
            operation checks if slot is locked and does not
            use it.

            Part of SSPUX350_072.

        Id = JAGae14881
            When a Cell Console client connects to the server,
            user name, system name and domain are parsed
            correctly, but IP address is not.

        Resolution:
            A new environment variable

            'OB2CRSSTRICTHOSTNAMECHECKING'

            is introduced. Setting its value to 1 is to enforce
            the use of hostnames obtained from IP address.

        Id = HSLco34255
            Improperly built Database Session Manager causes
            omnirpt to fail.

        Resolution:
            Properly built Database Session Manager in included
            in patch.

        PHSS_25002:
        Id = HSLco24755
            Rescan before backup option incorrectly deletes locked
            slots information from OmniBack II database.

        Resolution:
            Locked slots are not updated during any rescan.

        Id = HSLco28232
            Backup session is in sleep mode during the
            pre/post-exec scripts execution. This can cause
            the session to last a long time.

        Resolution:
            New global option is introduced. Details:

            name: PrePostExecOnEveryVolumeForHostBackup

            format:

                PrePostExecOnEveryVolumeForHostBackup=<0 or 1>

                default: 0

                If this option is set (=1), Backup Disk Agent (BDA)
                will execute pre/post-exec scripts for every
                volume of host object specified.
                If this option is not set (=0), Backup Session
                Manager (BSM) will execute pre-exec script
                prior to starting first volume BDA and post-exec
                script after last volume BDA. During the
                execution of these scripts, the BSM will sleep.

        Id = HSLco28279
            In some special cases it is possible for purge of
            filenames to fail with error written in the debug.log:

              "DB[9] internal error [-16]
               record not connected to set."

        Resolution:
            Purge is improved in order to correctly remove
            such records.

        Id = HSLco29098
            After the mount request during restore from SCSI-II
            library, OmniBack II tries to load "" medium into drive.

        Resolution:
            Restore session manager rechecks the configuration
            after the mount request is confirmed.

            Part of SSPUX350_048.

        Id = HSLco30814
            By design, OmniBack II ends session as 'Failed' if
            there are no objects to back up.

        Resolution:
            Two new global variables have been introduced:

              1) SessSucessfullWhenNoObjectsBackedUp=0
              By setting this variable to 1 user can change the
              Omniback II behavior in order to end the session
              as successful when there are no objects backed up.

              2) TreatScriptReturnAsNormal=<script return>
              Setting this variable to a certain number instructs
              OmniBack II to treat all the script returns equal
              to the specified number as normal.

            Part of SSPUX350_062.

        Id = HSLco31142
            There is no warning reported when one creates a datalist
            or a barlist with load balancing enabled and minimum
            number of devices greater than number of configured
            logical devices.

        Resolution:
            Comparison of minimum and configured devices number
            is implemented.

        Id = HSLco31295
            Media Session Manager does not send abort message to
            Backup Media Agent started after Copy Media Agent
            failed.

        Resolution:
            Media Session Manager properly handles abort message
            from Copy Media Agent.

        Id = HSLco31325
            1) Error in Backup Session Manager.
               When OmniBack II - Informix backup aborting,
               another session starts and finishes the remaining
               database spaces.

            2) Informix wrong error handling.

        Resolution:
            1) Case BSM_STATE_ABORTING was changed in the order
               that Backup Session Manager aborts session when
               requested.

            2) The way of translating OmniBack II errors into
               Informix errors was changed with new condition
               checking.

            Part of SSPUX350_063.

        Id = JAGad86475
            Cell Request Server and session managers abort
            because of an accept() command failure on some
            HP-UX 11.x systems.

        Resolution:
            accept() command is re-executed in case of
            ENOBUFS failure.

            Part of SSPUX350_059.

        PHSS_24658:
        Id = JAGad48558
            Initializition with "Autolabel" option creates
            duplicated tape labels.

        Resolution:
            Medium initialization does not create duplicated tape
            labels.

        Id = JAGad64442
            OmniBack II internal database ownership belongs to
            primary node instead of floating hostname in
            MC/ServiceGuard environment.

        Resolution:
            Database ownership is set to floating hostname.

        Id = NSMex03907
            The data backed up with an older version of OmniBack II
            and option "-encrypt" can not be selected from
            Restore GUI.

        Resolution:
            It is possible to select objects backed up with an
            older version of OmniBack II in Restore GUI.

        Id = NSMex04086
            Message level of a resuming failure in XP environment
            is set to "Normal" instead of "Major".

        Resolution:
            Message level is corrected.

        Id = NSMex04149
            Cell Request Service (CRS) executes "omnidbutil -clear"
            and returns incorrect exit code.

        Resolution:
            Correct exit code is returned.

        Id = NSMex04164
            The parser incorrectly enumerates schedule types.

        Resolution:
            Schedule types are properly enumerated.

            Part of SSPUX350_039.

        Id = NSMex04283
            OmniBack II is not able to list all interfaces in cells
            with more than 20 LAN cards because the buffer is too
            small.

        Resolution:
            Buffer for storing interfaces is increased.

        Id = NSMex04287
            OmniBack II does not lock all available devices.

        Resolution:
            Load balancing locks enough available devices to be used
            for a session.

        Id = NSMex04319
            When there is no more media available for the running
            session, mount request is issued. This mount request can
            not be confirmed because the drive is locked by Backup
            Session Manager.

        Resolution:
            Media Session Manager ignores Backup Session Manager
            lock making the slot free for mount request
            confirmation.

        Id = NSMex04311
            OmniBack II improperly recognizes post-exec script as a
            start request if pre-exec script fails in cluster
            environment.

        Resolution:
            OB2FORCEPOSTEXEC environment variable is added.
            Setting its value to 1 in the .omnirc file causes
            post-exec scripts to be started regardless of pre-exec
            script exit code.

            Part of SSPUX350_040.

        Id = NSMex04403
            Reporting functionality is missing in Media Session
            Manager.

        Resolution:
            Reporting functionality is added to Media Session
            Manager.

            Part of SSPUX350_042.

        Id = NSMex04540
            After the mount request during restore from SCSI-II
            library, Omniback tries to load "" medium into drive.

        Resolution:
            Restore session manager rechecks the configuration
            after the mount request is confirmed.

        PHSS_23470:
        Id = JAGad36093
            If one of the agent fails session status should
            indicate "Completed/Errors" instead of "Completed".

        Resolution:
            Session status is correct.

            Part of SSPUX350_027.

        Id = NSMbb37729
            Database Session Manager starts Device Browser with
            incorrect options.

        Resolution:
            Structure containing Device Browser options is
            initialized before it is filled with the parameters.

        Id = NSMex03425
            Backup of SAP archive logs fails if a backup request
            for next archive log comes when Backup Session Manager
            is already exiting.

        Resolution:
            Datalist entries for BAR session are removed.

        Id = NSMex03621
            When restoring the data from STK or GRAU library,
            wrong medium is loaded into drive after the mount
            request confirmation.

        Resolution:
            Mount request is properly handled.

        Id = NSMex03701
            Backing up Informix Parallel Server with many
            datafiles where request is coming from the node
            that is not specified in Informix backup
            specification results in many warning messages reported
            during the session.

        Resolution:
            New global option InformixparallelBackupIgnoreWarning
            is added. Warnings are ignored if this option is set
            to 1. Default value is 0.

        Id = NSMex03711
            Licensing is not working properly for systems with
            more than 20 lan cards, due to an OmniBack limitation.

        Resolution:
            Number of lan cards on a single system can be up to 100.

        Id = NSMex03739
            Pre- and post-exec scripts return invalid exit status
            because of timing problem.

        Resolution:
            Environment variable OB2EXECTIMEOUT is introduced.
            Variable represents timeout (in seconds) after the end
            of pre- and post-exec script. Default value is 0.
            Recommended value is between 5 and 10 seconds.

        Id = NSMex03847
            New Media Class, 9840, is introduced with A.03.50
            release. This caused that some of previously created
            devices did not work with OmniBack II 3.50.

        Resolution:
            New utility, mchange, changes media class for a pool
            and for all devices that use the particular pool.
            Usage of mchange is:

              mchange -version | -help
              mchange -pool PoolName -newtype NewMediaClass

        Id = NSMex03894
            OmniBack II has a 600 mountpoints limitation. Host
            backup fails if there are more than 600 mountpoints.

        Resolution:
            Number of mountpoints per host increased to 50000.

        Id = NSMex03910
            Major messages are not checked by Backup Session
            Manager.

        Resolution:
            Backup Session Manager checks all messages.

        Id = NSMex03917
            If "omnidbutil -cdbsync" command is started in
            Service Guard environment, some objects disappear
            from OmniBack II internal database.

        Resolution:
            omnidbutil works properly in Service Guard
            environment.

            Part of SSPUX350_026.

        Id = NSMex03991
            Backup Session Manager incorrectly appends full
            Oracle backups.

        Resolution:
            Backup Session Manager correctly checks properties
            of pool.

        Id = NSMbb38972
            omnitrig does not support MS Exchange 2000 integration.

        Resolution:
            Scheduled MS Exchange 2000 backups are properly
            started.

            Part of SSPUX350_020.

        Id = NSMex03246
            Normal, Warning and Minor messages can be seen on ITO
            Management server even though OVfilter is set up to
            forward only Critical messages.

        Resolution:
            Messages are forwarded according to OVfilter setup.

        Id = NSMex04159
            When Backup Session Manager waits for the next client it
            disables new client connections.

        Resolution:
            Proper previously failed session is restarted.

        Id = NSMex04261
            Import of integration session fails if the session is
            spanned over two or more media.

        Resolution:
            Checking for object description is changed.

        PHSS_23105:
        Id = NSMex03757
            Performance degrated by up to 50% after upgrade from
            OmniBack II 2.55 or 3.00.

        Resolution:
            Redundant update of the objects removed.

            Part of SSPUX350_023.

        Id = NSMex03977
            Listing of objects failed for the objects that have
            been purged from the database, because there is no
            link between objects and object versions.

        Resolution:
            Fix is implemented in libob2ecbd.sl.

        PHSS_22369:
        Id = JAGad13634
            File /opt/omni/sbin/nb_informix is missing.

        Resolution:
            File /opt/omni/sbin/nb_informix is added to OMNI-CS
            fileset.

        Id = JAGad17029
            Using "List from media" option in restore context
            ignores "See private objects" option. Objects that are
            backed up as "Private" are not listed.

        Resolution:
            Option parsing in restore context is improved.

        Id = NSMex03356
            If there are more than 100 network interfaces, ioctl()
            call fails.

        Resolution:
            Buffer for SIOCGIFCONF is increased to support up to
            1000 network interfaces.

        Id = NSMex03365
            When backup and file search sessions are started in
            parallel, file search session locks the database.
            Backup Session Manager tries to write backup
            information into locked database. Since this action can
            not be performed, the following messages are logged
            in the rds.log:

              "11740 [10-Apr-00 17:37:07] error status=5
               11741 [10-Apr-00 17:37:07] GROUPLOCK ELEMENT:
                userID=4, LockType=6, LockMode= *, RecSetType=10002,
                dba=[0:0], odnum=1"

        Resolution:
            File pattern search is optimized to minimize the
            possibilities of group locks.

        Id = NSMex03419
            OmniBack II 3.50 objects are case insensitive which is
            not true for the SAP objects backed up with 2.55
            version. Object tape format is changed with 3.50 as
            well. These changes caused some SAP objects not to be
            displayed in the Restore GUI after importing the tape
            with SAP objects from 2.55 to 3.50.

        Resolution:
            Object names from tape are converted into OmniBack II
            3.50 format after tape import from 2.55.

        Id = NSMex03466
            System name checking is not performed for systems with
            multiple LAN cards. Backup Session Manager is checking
            the system names only when looking for clusters.

        Resolution:
            System name checking is performed when looking for
            clusters and systems with multiple LAN cards.

        Id = NSMex03481
            Aborting backup session is not possible because
            Backup Session Manager incorrectly aborts Disk Agents
            after the package switch.

        Resolution:
            Disk Agents are properly aborted.

        Id = NSMex03491, JAGad28516
            In host backup only mount point directories can be
            excluded. If a directory is not a mount point then it
            cannot be excluded from the backup.

        Resolution:
            Non-mountpoint directories can now be excluded.

        Id = NSMex03493
            Scheduled reports are not started with "-debug" option
            although omnitrig is.

        Resolution:
            Command line option passing is implemented for omnirpt.

        Id = NSMex03583, NSMex03631
            Mount request is not properly implemented for SCSI-II
            changer devices.

        Resolution:
            OmniBack II properly handles mount requests.

        Id = NSMex03638
            Option "-change_objname" is not meant to be a part of
            OmniBack II A.03.50.

        Resolution:
            Option "-change_objname" is removed.

        Id = NSMex03501
            After upgrading OmniBack ServiceGuard package from
            3.00 to 3.50, it is not possible to list media due to
            incorrect ownership of medium.

        Resolution:
            Virtual hostname is used for medium ownership.

            Part of SSPUX350_001.

        Id = NSMex03683
            Copy session is aborted when copying a write-protected
            tape. When write-protected tape in the source drive is
            checked, the cleaning tape for that drive is requested
            and the following message appears:

              "Cleaning tape requested by device <device_name>.
               Please clean the drive.".

        Resolution:
            The cleanme signal is now processed correctly.

            Part of SSPUX350_004.

        Id = NSMex02584
            Execution of command

              "omnidb -filesystem <FS_Object> -file <File_Name>"

            causes a memory leak in RDS (approx. 300 bytes). If the
            command is started more than 100000 times, it can cause
            RDS to die due to a lack of memory.

        Resolution:
            Fix is implemented in libob2ecdb.sl.

            Part of SSPUX350_006.

        Id = NSMex03702
            RDS dies during a large SAP restore due to memory leak
            described in NSMex02584.

        Resolution:
            Fix is implemented in libob2ecbd.sl.

            Part of SSPUX350_006.

        Id = NSMex03289
            Media sync does not work properly when table of
            exported/recycled media gets too big (>3000 media).
            Some new sessions dissapear from database. No error is
            reported.

        Resolution:
            Improved error handling logs this event in debug.log.

            Part of SSPUX350_003.

        Id = NSMex03521
            Database stays in the hot mode after issuing an
            "omnidbcheck" command. If a large amount of data is
            written before OmniBack II daemons are stopped, it can
            happen that hot files are not properly flushed. This
            causes corruption of database.

        Resolution:
            omnidbcheck flushes hot files immediately after
            database check.

            Part of SSPUX350_003.

        Id = NSMex03737
            Media Session Manager is incorrectly initializing media
            in ServiceGuard environment. Owner of medium is set to
            hostname of the active node. This results in wrong
            medium handling and objects from such medium are
            removed from the OmniBack II database each time Media
            Session Manager is started.

        Resolution:
            Initialization of media in ServiceGuard environment
            is improved.

            Before applying the fix for NSMex03737 please run
            following commands:

              omnidbutil -change_cell_name <hostname1>

            and

              omnidbutil -change_cell_name <hostname2>

            where <hostname1> and <hostname2> are names of
            ServiceGuard nodes.

            Part of SSPUX350_010.

        Id = NSMex03758, NSMex03759, NSMex03646
            OmniBack II reports an error:

              "Database is probably corrupt."

            for backup sessions that span over two or more media
            if one of them is already overwritten/exported because
            then some of the objects are already removed from the
            database.

        Resolution:
            Removed objects are skipped during the database queries.

            Part of SSPUX350_010.

SR:
        H555009863 H555009297 H555009560 H555009843 H555008927
        H555008892 B554000611 B554000630 B554000712 B554000622
        B554000550 B554000650 B554000623 B554000830 B554000831
        B554000813 B554000418 B554000751 B554000761 B554000556
        B554000487 B554000496 B554000776 B554000867 B554000597
        B554000887 B554000888 B554000889 B555002886 H555008533
        H555008832 H555004477 H555008807 H555008780 H555008690
        H555008261 8606262839 H555008452 H555008410 B554000768
        8606221771 8606248483 H555007191 H555003134 H555007796
        H555007428 H555006924 8606236143 H555005975 H555005922
        H555006248 B555011718 H555006771 H555006710 H555006799
        H555006810 8606217323 H555005697 H555005402 H555005732
        H555005680 H555005149 H555004871 H555005681 H555005583
        H555005917 H555005973 8606179334 8606195237 H555004061
        H555004026 H555004027 B555008272 H555005234 H555004452
        H555003831 B554000869 H555005624 H555004364 H555004475
        B554000372 B554000841 H555004021 8606166806 H555004350
        8606159187 8606144294 8606147687

Patch Files:
        /opt/omni/lbin/crs
        /opt/omni/lbin/bsm
        /opt/omni/lbin/dbsm
        /opt/omni/lbin/msm
        /opt/omni/lbin/mmd
        /opt/omni/lbin/rsm
        /opt/omni/lbin/psm
        /opt/omni/lbin/dbbda
        /opt/omni/sbin/omnitrig
        /opt/omni/sbin/omnidbutil
        /opt/omni/sbin/omnidbcheck
        /opt/omni/sbin/nb_informix
        /opt/omni/sbin/utilns/mchange
        /opt/omni/sbin/install/omniforsg.ksh
        /opt/omni/lib/libob2ecmn.sl
        /opt/omni/lib/libob2ecdb.sl
        /opt/omni/lib/libob2emmdb.sl
        /opt/omni/lib/libob2eadm.sl
        /opt/omni/newconfig/etc/opt/omni/options/global
        /opt/omni/newconfig/etc/opt/omni/sg/csfailover.ksh

what(1) Output:
        /opt/omni/lbin/crs:
                [TZ=GMT0 /opt/omni/lbin/crs -version]
                HP OpenView OmniBack II A.03.50: CRS, internal build
                         PHSS_28021/PHSS_28022, built on Wed Nov 20
                        13:11:01 2002
        /opt/omni/lbin/bsm:
                [TZ=GMT0 /opt/omni/lbin/bsm -version]
                HP OpenView OmniBack II A.03.50: BSM, internal build
                         PHSS_28727/PHSS_28728, built on Wed Mar 26
                        11:11:09 2003
        /opt/omni/lbin/dbsm:
                [TZ=GMT0 /opt/omni/lbin/dbsm -version]
                HP OpenView OmniBack II A.03.50: DBSM, internal buil
                        d PHSS_28021/PHSS_28022, built on Wed Nov 20
                         12:01:28 2002
        /opt/omni/lbin/msm:
                [TZ=GMT0 /opt/omni/lbin/msm -version]
                HP OpenView OmniBack II A.03.50: MSM, internal build
                         PHSS_28021/PHSS_28022, built on Wed Nov 20
                        11:44:13 2002
        /opt/omni/lbin/mmd:
                [TZ=GMT0 /opt/omni/lbin/mmd -version]
                HP OpenView OmniBack II A.03.50: MMD, internal build
                         PHSS_28021/PHSS_28022, built on Wed Nov 20
                        12:12:19 2002
        /opt/omni/lbin/rsm:
                [TZ=GMT0 /opt/omni/lbin/rsm -version]
                HP OpenView OmniBack II A.03.50: RSM, internal build
                         PHSS_28021/PHSS_28022, built on Wed Nov 20
                        11:32:05 2002
        /opt/omni/lbin/psm:
                [TZ=GMT0 /opt/omni/lbin/psm -version]
                HP OpenView OmniBack II A.03.50: PSM, internal build
                         PHSS_28021/PHSS_28022, built on Thu Nov 21
                        10:10:36 2002
        /opt/omni/lbin/dbbda:
                [TZ=GMT0 /opt/omni/lbin/dbbda -version]
                HP OpenView OmniBack II A.03.50: DBBDA, internal bui
                        ld PHSS_28021/PHSS_28022, built on Thu Nov 2
                        1 09:47:19 2002
        /opt/omni/sbin/omnitrig:
                [TZ=GMT0 /opt/omni/sbin/omnitrig -version]
                HP OpenView OmniBack II A.03.50: OMNITRIG, internal
                        build PHSS_28727/PHSS_28728, built on Tue Ma
                        r 25 10:08:42 2003
        /opt/omni/sbin/omnidbutil:
                [TZ=GMT0 /opt/omni/sbin/omnidbutil -version]
                HP OpenView OmniBack II A.03.50: OMNIDBUTIL, interna
                        l build PHSS_28021/PHSS_28022, built on Thu
                        Nov 21 10:10:16 2002
        /opt/omni/sbin/omnidbcheck:
                [TZ=GMT0 /opt/omni/sbin/omnidbcheck -version]
                HP OpenView OmniBack II A.03.50: OMNIDBCHECK, intern
                        al build PHSS_28021/PHSS_28022, built on Thu
                         Nov 21 10:10:26 2002
        /opt/omni/sbin/nb_informix:
                None
        /opt/omni/sbin/utilns/mchange:
                [TZ=GMT0 /opt/omni/sbin/utilns/mchange -version]
                HP OpenView OmniBack II A.03.50: MCHANGE, internal b
                        uild PHSS_23470/PHSS_23471, built on Fri Mar
                          2 10:43:47 2001
        /opt/omni/sbin/install/omniforsg.ksh:
                None
        /opt/omni/lib/libob2ecmn.sl:
                None
        /opt/omni/lib/libob2ecdb.sl:
                None
        /opt/omni/lib/libob2emmdb.sl:
                None
        /opt/omni/lib/libob2eadm.sl:
                None
        /opt/omni/newconfig/etc/opt/omni/options/global:
                None
        /opt/omni/newconfig/etc/opt/omni/sg/csfailover.ksh:
                None

cksum(1) Output:
        612034413 726899 /opt/omni/lbin/crs
        1218843371 1182707 /opt/omni/lbin/bsm
        1264986274 1239560 /opt/omni/lbin/dbsm
        3952351799 694260 /opt/omni/lbin/msm
        1499776461 530043 /opt/omni/lbin/mmd
        3337452184 874939 /opt/omni/lbin/rsm
        2483849962 435578 /opt/omni/lbin/psm
        2181795817 365783 /opt/omni/lbin/dbbda
        50284200 406791 /opt/omni/sbin/omnitrig
        2522875831 697971 /opt/omni/sbin/omnidbutil
        3950965868 472364 /opt/omni/sbin/omnidbcheck
        2755861046 353611 /opt/omni/sbin/nb_informix
        161435393 209564 /opt/omni/sbin/utilns/mchange
        3275622251 5084 /opt/omni/sbin/install/omniforsg.ksh
        114168317 812458 /opt/omni/lib/libob2ecmn.sl
        1916829165 885460 /opt/omni/lib/libob2ecdb.sl
        1619154841 651912 /opt/omni/lib/libob2emmdb.sl
        3526392551 692720 /opt/omni/lib/libob2eadm.sl
        2258981330 34415 /opt/omni/newconfig/etc/opt/omni/options/
                global
        1805127806 2350 /opt/omni/newconfig/etc/opt/omni/sg/
                csfailover.ksh

Patch Conflicts: None

Patch Dependencies: None

Hardware Dependencies: None

Other Dependencies:
        If any newer SSP for the Cell Server is installed
        on your system, you must re-apply the SSP after
        installing this Cell Server patch.

        PHSS_28725:
        Release Date: Available
        Id = HSLco40537 SR:H555009863
        Id = HSLco20414 SR:H555003134
        Id = HSLco37193 SR:H555008807
        PHSS_28725 is required for these defect fixes.

        PHSS_28578:
        Release Date: Available
        Id = HSLco40537 SR:H555009863
        PHSS_28578 is required for this defect fix.

        PHSS_28570:
        Release Date: Available
        Id = HSLco40537 SR:H555009863
        Id = HSLco37193 SR:H555008807
        Bad catalog access messages are displayed without
        PHSS_28570.

        PHSS_28019:
        Release Date: Available
        Id = HSLco37193 SR:H555008807
        PHSS_28019 is required for this defect fix.

        PHSS_28017:
        Release Date: Available
        Id = HSLco40537 SR:H555009863
        Id = HSLco30814 SR:H555006710
        Id = HSLco37193 SR:H555008807
        PHSS_28017 is required for these defect fixes.

        PHSS_27589:
        Release date: Available
        Id = HSLco20414 SR:H555003134
        Id = NSMex03638 SR:B554000768
        PHSS_27589 is required for these defect fixes.

        PHSS_25950:
        Release date: Available
        Id = HSLco31325 SR:H555006810
        PHSS_25950 is required for this defect fix.

Supersedes:
        PHSS_22369 PHSS_23105 PHSS_23470 PHSS_24658 PHSS_25002 PHSS_26347
        PHSS_26889 PHSS_28021

Equivalent Patches:
        PHSS_28728:
        s700: 11.00 11.11 11.20
        s800: 11.00 11.11 11.20

Patch Package Size: 11090 KBytes

Installation Instructions:
        Please review all instructions and the Hewlett-Packard
        SupportLine User Guide or your Hewlett-Packard support terms
        and conditions for precautions, scope of license,
        restrictions, and, limitation of liability and warranties,
        before installing this patch.
        ------------------------------------------------------------
        1. Back up your system before installing a patch.

        2. Login as root.

        3. Copy the patch to the /tmp directory.

        4. Move to the /tmp directory and unshar the patch:

                cd /tmp
                sh PHSS_28727

        5a. For a standalone system, run swinstall to install the
            patch:

                swinstall -x autoreboot=true -x match_target=true \
                        -s /tmp/PHSS_28727.depot

        By default swinstall will archive the original software in
        /var/adm/sw/patch/PHSS_28727. If you do not wish to retain a
        copy of the original software, you can create an empty file
        named /var/adm/sw/patch/PATCH_NOSAVE.

        WARNING: If this file exists when a patch is installed, the
                 patch cannot be deinstalled. Please be careful
                 when using this feature.

        It is recommended that you move the PHSS_28727.text file to
        /var/adm/sw/patch for future reference.

        To put this patch on a magnetic tape and install from the
        tape drive, use the command:

                dd if=/tmp/PHSS_28727.depot of=/dev/rmt/0m bs=2k

Special Installation Instructions:
        PHSS_28727:
        NOTE!
        This Patch has to be installed on the Cell Manager host.
        OmniBack II Services must be shut down before the patch is
        installed. Use the following command to shut down the
        services:

           "/opt/omni/sbin/omnisv.sh stop".

        After the installation is complete, restart OmniBack II
        Services using "/opt/omni/sbin/omnisv.sh start".

        Patch includes the following Site Specific Patches:
           SSPUX350_001
           SSPUX350_003
           SSPUX350_004
           SSPUX350_006
           SSPUX350_010
           SSPUX350_020
           SSPUX350_023
           SSPUX350_026
           SSPUX350_027
           SSPUX350_038
           SSPUX350_039
           SSPUX350_040
           SSPUX350_042
           SSPUX350_048
           SSPUX350_059
           SSPUX350_062
           SSPUX350_063
           SSPUX350_066
           SSPUX350_072
           SSPUX350_076
           SSPUX350_077
           SSPUX350_080
           SSPUX350_085
           SSPUX350_087
           SSPUX350_088
           SSPUX350_089
-----End of Document ID: PHSS_28727------------------------------------------


Document ID: PHSS_28725
Date Loaded: 20030404
      Title: s700_800 10.X OV OB3.50 patch - CC packet

Patch Name: PHSS_28725

Patch Description: s700_800 10.X OV OB3.50 patch - CC packet

Creation Date: 03/03/24

Post Date: 03/04/04

Hardware Platforms - OS Releases:
        s700: 10.00 10.01 10.10 10.20
        s800: 10.00 10.01 10.10 10.20

Products:
        OmniBackII A.03.50

Filesets:
        OMNIBACK-II.OMNI-HPUX-P,A.03.50
        OMNIBACK-II.OMNI-OTHUX-P,A.03.50

Automatic Reboot?: No

Status: General Release

Critical: No

Path Name: /hp-ux_patches/s700_800/10.X/PHSS_28725

Symptoms:
        PHSS_28725:
        Id = HSLco39486 SR:H555009404
            GUI started with "xomni -restore -debug 1-99"
            ends abnormally when Informix server option in
            Restore context is selected.

        Id = HSLco40532 SR:H555009862
            When starting "omnir -mssql -barhost <host> -base
            <basename>", restore ends with:

              "Set '<basename>:0' not found. Most probably there
               is a DNS configuration problem or one of the systems
               is not in the same Cell Manager system."

        Id = HSLco40537 SR:H555009863
            When backing up very large SAP databases with SSEA
            split mirror, backups can fail with error:

              "BR280I Time stamp <time>
               BR296I Split of mirror disks successful
               BR274E File /<sapdata_path>/system.data1 not found"

        PHSS_28222:
        Id = HSLco37193 SR:H555008807
            When backing up SAP integration with EMC split mirror
            functionality, not all the SAP files are backed up.

        Id = HSLco37723 SR: H555008892
            If a Manager-of-Managers Server is also a
            MC/ServiceGuard virtual node, then the command
            "omnirpt -report list_sessions -timeframe
             <start_hours_ago><hours_duration>
             -multicell -no_multiple"
            lists the matching sessions from this node twice.

        PHSS_27595:
        Id = HSLco31733 SR: H555006893
            Additional dates added to periodic backup schedule
            after 13 months.

        Id = HSLco35611 SR: H555008476
            Restore GUI can not handle two separate Oracle7
            databases with the same SID. GUI does not display
            all objects versions.

        Id = HSLco35661 SR: H555008490
            Filesystem restore summary displays incorrect version
            of file selected for restore.

        Id = HSLco36478 SR: H555008657
            GUI ends abnormally when trying to perform Informix
            restore.

        Id = HSLco36904 SR: H555008730
            xomnimm reports "Internal error" when trying to load
            large media pool or device.

        Id = JAGad97576 SR: 8606228519
            Command Line (CLI) command omnimcopy does not provide
            error codes.

        Id = HSLco36916 SR: H555008732
            HP-UX GUI corrupts barlists for SSEA backup created
            using Windows GUI.

        PHSS_25956:
        Id = HSLco28793 SR: H555006144
            Omnir command starts multiple Database Session
            Managers.

        Id = HSLco29971 SR: H555006524
            Double-clicking an existing EMC datalist results in
            the following error:

              "Unknown object type encountered.".

        Id = HSLco31433 SR: H555006834
            omnir incorrectly parses "-srdf_smmf" option.

        Id = HSLco31734 SR: H555006894
            OmniBack does not select all the objects with the
            same timestamp.

        Id = JAGad57038 SR: 8606187829
            "Omnidb -filesystem -detail" generates output in which
            Object Name and Object Type files contents are
            reversed.

        PHSS_24660:
        Id = NSMex03922
           Listing of Oracle objects on GUI fails.

        Id = NSMex03986
            Omnir core dumps.

        Id = NSMex04296
            Backup scheduler shows incorrect dates.

        Id = NSMex04323
            Command "omnimm -enter [slot_range]" returns invalid
            slot error.

        Id = NSMex04347
            Restore to a different host fails with an error:

              "Can not stat script /usr/omni/bin/(null).".

        Id = NSMbb39907
            Any attempt to change object format in Oracle8 RMAN
            script using OmniBack II GUI fails with the following
            error:

              "[12:1645] Format of RMAN channel names is not
               correct.".

        Id = HSLco20414
            Device maintenance from command line is not sufficient.

        Id = NSMex03989
            Command

              "omnirpt -report db_size -html -email <e-address>"

            works improperly.

        Id = NSMex04439
            omnib command ignores "-encode" option.

        Id = NSMbb38972
            Exchange 2000 backup cannot be started from command
            line.

        PHSS_22850:
        Id = JAGad30352
            "EMC Support" tab is not available in
            "Backup Specification - Options" GUI.

        Id = JAGad35002
            If database integration in a MC/ServiceGuard cluster is
            backed up, the backup can report an error.

        Id = NSMex03419
            After importing a tape from 2.55 to 3.50 cell some of
            the files can not be restored.

        Id = NSMex03475
            Restore GUI does not display SAP objects, if two
            SAP instances with the same name are backed up on
            different host.

        Id = NSMex03505
            a) When selecting restore of SAP object, message
            "Cannot browse from root" appears.

            b) When selecting restore from File System Restore
            Dialog GUI might core dump.

        Id = NSMex03658
            Exit code of omniminit is incorrect.

        Id = NSMex03833
            The options under Edit button are not accessible even
            if user has rights.

        Id = JAGad29457
            Ownership incorrectly displayed within restore GUI.

        Id = JAGad33161
            Datalists/barlists with EMC integration are incorrectly
            created.

        PHSS_22038:
        Id = NSMex03503
            Users with only "Start Backup" privilege can delete
            datalists.

        Id = NSMex03511
            "Send external" method always executes external script
            on Cell Manager system.

Defect Description:
        PHSS_28725:
        Id = HSLco39486
            DbgPlain function is called with wrong string format.

        Resolution:
            String format for DbgPlain() is corrected.

        Id = HSLco40532
            The source of <basename> is not parsed.

        Resolution:
            The source of <basename> is parsed.

        Id = HSLco40537
            In split mirror environment with very large SAP
            databases, it can happen that the size of the message
            buffer that OmniBack II uses is too small to fit in
            for the complete list of SAP files to be backed up.

        Resolution:
            New environment variable is introduced: OB2IPCBUFSIZE.
            In order to solve this problem, the buffer size can
            be increased by setting the OB2IPCBUFSIZE environment
            variable in the .omnirc file on CM, R1 and R2 hosts,
            specifying the desired amount of memory to be used
            for the buffer.

            For determining buffer size please see the Resolution
            of Id = HSLco37193 below.

            Part of SSPUX350_088.

        PHSS_28222:
        Id = HSLco37193 SR:H555008807
            In split mirror environment with huge SAP databases
            it can happen that the size of the message buffer
            OmniBack II uses is too small to receive complete list
            of SAP files to be backed up.

        Resolution:
            Setting the OB2IPCBUFSIZE environment variable in the
            /opt/omni/.omnirc file on Cell Server, R1 and R2 hosts,
            specifying the desired amount of memory to be used for
            the buffer solves the described problem.
            Please read the following instructions and make sure
            that the patches listed in "Other Dependencies" section
            (see below) are installed and the environment
            variable is set on Cell Server, R1 and R2 systems before
            running the backup!

            How to determine the buffer size?
            ---------------------------------

            N_obj: number of objects (files)
            N_fs: number of file systems
            N_lvmvg: number of volume groups
            N_dg: number of disk groups
            N_rdsk: number of rawdisks
            Obj: Object Name
            ObjBack: Object Backup Name
            MntPathLen: Path name on backup (R2) host
                         (example: /var/opt/omni/tmp/App_host)
            fsmnt: File System Mount Point
            fsdev: File System Device File
                         (example: /dev/dsk/[c0t1d1,lvol1])
            vg: Volume group
                         (ex: /dev/vg01)
            dg: Disk group (VxVM) - dependence on mapfile
                         which is required for creating disk group
                         (example:/dev/vx/dsk/dg01)
            rdsk: Raw disk file name
                         (example: /dev/rdsk/c1t1d1)
            AvgLen_<xxx> average length of <xxx>

            There are two different buffers used:

            1. BSM <-> R1
            2. R1 <-> R2

            Calculating the BSM <-> R1 buffer size
            --------------------------------------
            MsgSize_BSM_R1 = N_obj * (AvgLen_Obj + 1 + MntPathLen)

            Calculating the R1 <-> R2 buffer size
            -------------------------------------
            MsgSize_R1_R2 =
              N_obj*(AvgLen_Obj+1+AvgLen_ObjBack) +
              N_fs*(AvgLen_fsmnt*2 + MntPathLen + AvgLen_fsdev*2)+
              N_lvmvg*(AvgLen_vg*2) + N_dg*(AvgLen_dg*2) +
              N_rdsk*(AvgLen_rdsk*2)

            Calculating the OB2IPCBUFSIZE value
            -----------------------------------
            OB2IPCBUFSIZE > max (MsgSize_BSM_R1, MsgSize_R1_R2)

            RESTORE NOTE:
            -------------
            If restore is started using the sapbda utility,
            the variable OB2IPCBUFSIZE must be exported to
            environment prior to starting sapbda.

            Known problems:
            ---------------
            If the calculated variable OB2IPCBUFSIZE is correctly
            set, but is still too small for the file list to fit
            into the message buffer, the session will fail with
            the following error seen in the report:

            BR295I Splitting mirror disks...
            BR280I Time stamp <time>
            BR279E Return code from '/opt/omni/lbin/ob2smbsplit
               /<sap_homedir_path>/.<filename>.lst': 2
            BR299E Split/resynchronization of mirror disks failed

            In this case the variable OB2IPCBUFSIZE must be
            recalculated to appropriate value. See above how to
            determine it.

            Part of SSPUX350_080.

        Id = HSLco37723
            Media handling results in IPC error when the buffer
            size is increased and variable OB2IPCBUFSIZE is set as
            described in above Resolution for problem HSLco37193.

        Resolution:
            Media Session Manager is rebuilt in order to properly
            include the changes introduced with Resolution for
            HSLco37193.

            Part of SSPUX350_085.

        PHSS_27595:
        Id = HSLco31733
            In next year the same date is not the same day in
            week. Scheduled dates after one year are just copied,
            so backups are scheduled on wrong days.

        Resolution:
            Days are correctly moved to next year.

        Id = HSLco35611
            GUI does not check on which host Oracle7 database is
            backed up and all backup versions are appended to
            the first one found.

        Resolution:
            Host matching and object version adding to list is
            improved.

        Id = HSLco35661
            Restore summary always displays the last version of
            file selected for restore.

        Resolution:
            Restore summary displays file versions as they were
            selected for restore.

        Id = HSLco36478
            Incorrect pointer handling causes GUI to end
            ungracefully.

        Resolution:
            Pointers are properly handled.

        Id = HSLco36904
            A buffer sent to xomnimm after loading large media pool
            or device is too big.

        Resolution:
            xomnimm reads the buffer size as specified in .omnirc
            file with OB2IPCBUFSIZE variable.

        Id = JAGad97576
            Omniback II reports the same exit code regardless of
            success or failure of the command omnimcopy.

        Resolution:
            When command omnimcopy fails Omniback II returns
            exit code 3 = EX_ERR_INTERNAL.

        Id = HSLco36916
            Saving a SSEA barlist with HP-UX GUI corrupts barlist.

        Resolution:
            Saving a barlist with HP-UX GUI is not possible.

            Part of SSPUX350_078.

        PHSS_25956:
        Id = HSLco28793
           New Database Session Manager instance is started
           every time when omnir is trying to retrieve object
           information from the database.

        Resolution:
            Omnir reuses existing connections.

            Part of SSPUX350_051.

        Id = HSLco29971
            Displaying EMC datalists is disabled.

        Resolution:
            Displaying EMC datalists is enabled.

            Part of SSPUX350_055.

        Id = HSLco31433
            When "-rawdisk" option is combined with "-srdf",
            "-smmf" or "-srdf_smmf", it is recognized only after
            latter options have been checked.

        Resolution:
            Option "-rawdisk" has higher priority.

        Id = HSLco31734
            Restore GUI incorrectly interprets the data obtained
            from Database Session Manager.

        Resolution:
            Restore GUI properly displays the latest versions of
            restore objects.

        Id = JAGad57038
            The order of putting Object Type and Object FileName
            into output files is wrong.

        Resolution:
            Object Type and Object FileName are displayed in
            correct order.

        PHSS_24660:
        Id = NSMex03922
            Incorrect memory usage causes GUI to core dump
            whilst listing Oracle sessions.

        Resolution:
            Memory usage is improved.

        Id = NSMex03986
            The omnir command causes a memory fault and core dumps
            if it is run with a long list of objects.

        Resolution:
            Omnir can handle long list of objects.

        Id = NSMex04296
            Backup scheduler loses months prior to January, 2002.

        Resolution:
            Scheduler optimization improved.

        Id = NSMex04323
            When executing "omnimm -enter [slot_range]" command
            a "0" is appended to slot range. This causes invalid
            slot error.

        Resolution:
            "omnimm -enter [slot_range]" command works properly.

        Id = NSMex04347
            Restore GUI improperly sends empty pre- and post-exec
            options to Restore Session Manager.

        Resolution:
            Fix is implemented in Restore GUI.

        Id = NSMbb39907
            It is impossible to define the object format in an
            Oracle8 RMAN script using the Omniback II GUI.

        Resolution:
            It is possible to change object format in Oracle8 RMAN
            script using OmniBack II GUI.

            Part of SSPUX350_031.

        Id = HSLco20414
            Device enabling, disabling and status report can not be
            performed using OmniBack II command line.

        Resolution:
            New options "-disable_device", "-enable_device" and
            "-device" are added to omnimm, omniupload and
            omnidownload.

            To disable/enable specific device and all other devices
            with the same lockname, run:
              omnimm -disable_device {device name}
              omnimm -enable_device {device name}

            To disable/enable all devices with the same lockname,
            run:
              omnimm -disable_lockname {lock name}
              omnimm -enable_lockname {lock name}

            To check if specific device is enabled/disabled, run:
              omnidownload -device {device name}

            Part of SSPUX350_038.

        Id = NSMex03989
            Command

              "omnirpt -report db_size -html -email <e-address>"

            returns HTML code instead of formatted report.

        Resolution:
            Missing header is added to HTML report.

        Id = NSMex04439
            omnib command ignores "-encode" option.

        Resolution:
            omnib command properly recognizes "-encode" option.

        Id = NSMbb38972
            Exchange 2000 backup cannot be started from command
            line.

        Resolution:
            It is possible to start Exchange 2000 backup from
            command line.

            Part of SSPUX350_020.

        PHSS_22850:
        Id = JAGad30352
            "EMC Support" tab is not available in
            "Backup Specification - Options" GUI, unless the
            cell_info entry for the Cell Manager has the
            "-emc" option.

        Resolution:
            xomnibackup now correctly checks cell_info file
            for "-emc" options.

        Id = JAGad35002
            a )Windows NT GUI supports cluster import which
            creates additional attributes in the cell info
            file to mark cluster nodes and virtual servers.
            MC/SG clusters do not have such support yet.

            b) Motif GUI does not have any way to import cluster
            in the cell. Session Manager starts agent on certain
            machine and expects that the connection will come
            from that machine or a physical node on a cluster. If
            additional attributes in the cell info are not set
            then SM aborts the connection.

        Resolution:
            .util shell script has been enhanced to allow import
            of the cluster using Windows GUI. The script handles
            messages INFO_CLUS and INFO_CLUS1 which allow the
            import to happen.

        Id = NSMex03419
           OmniBack II 3.50 objects are case insensitive which is
           not true for the SAP objects backed up with 2.55
           version. Object tape format is changed with 3.50 as
           well. These changes caused some SAP objects not to be
           displayed in the Restore GUI after importing the tape
           with SAP objects from 2.55 to 3.50.

        Resolution:
           Names are tape format are converted into OmniBack II
           3.50 format after tape import from 2.55.

        Id = NSMex03475
            Restore GUI does not display SAP objects, if two
            SAP instances with the same name are backed up on
            different host.

        Resolution:
            xomnirestore has been improved to show all object.

        Id = NSMex03505
            a) When selecting restore of SAP object, message
            "Cannot browse from root" appears.
            b) Two different structures with the same name
            were defined.

        Resolution:
            xomnirestore has been improved.

        Id = NSMex03658
            Exit code 0 is returned when the medium initialization
            fails with error:

            "This medium can be initialized only with force option
            specified."

        Resolution:
            Exit code of omniminit for failed operation is
            redefined.

        Id = NSMex03833
            User rights are not properly interpreted.

        Resolution:
            User rights permissions has been modified.

        Id = JAGad29457
            xomnirestore shows user name and group name for backed
            up objects. If users on different clients have
            different UID and GID wrong user will be shown in
            version browser.

        Resolution:
            New option GUIShowUID has to be set in file:
            /etc/opt/omni/options/global on Cell Manager host.

            GUIShowUID=<number>

            where <number> means:
            - 0, GUI converts UIDs and GIDs to strings
            - 1, only UIDs and GIDs numbers will be showen

            Part of SSPUX350_013.

        Id = JAGad33161
            Options for EMC integration are incorrectly saved when
            datalist/barlist is created with Motif GUI.

        Resolution:
           EMC type resolving has been improved.

           Part of SSPUX350_013.

        PHSS_22038:
        Id = NSMex03503
            User rights are not properly checked.

        Resolution:
            User rights checking is properly improved.

        Id = NSMex03511
            Execution of external script can not be prevented.

        Resolution:
            Omnirpt is changed so that the execution of "Send
            external" method can be controlled by adding a line

            ExternalScriptMode=<number>

            in Global Options file, where <number> means:

            - 0, no checking is performed
            - 1, script can be executed only in bin directory
            - 2, executing of external scripts is not allowed.

SR:
        H555009862 H555009592 H555009404 H555009863 H555008927
        H555008892 H555008803 H555008807 H555008476 H555008657
        H555006893 H555008730 B554000640 B554000632 H555008732
        H555008490 8606228519 H555006524 H555006894 H555006834
        H555006144 8606187829 H555004942 H555003134 8606179663
        H555005709 H555005547 H555005845 H555004369 H555004246
        H555004381 8606160131 8606161034 8606163859 B554000788
        8606165711 B554000550 H555003728 B554000606 B554000634

Patch Files:
        /opt/omni/databases/vendor/cc/hp/s800/hp-ux-1020/A.03.50/
                packet.Z
        /opt/omni/databases/vendor/cc/hp/s800/hp-ux-10/A.03.50/
                packet.Z
        /opt/omni/databases/vendor/cc/hp/s800/hp-ux-11/A.03.50/
                packet.Z
        /opt/omni/databases/vendor/cc/ncr/i386/mp-ras/A.03.50/
                packet.Z
        /opt/omni/databases/vendor/cc/dec/alpha/osf1-4/A.03.50/
                packet.Z
        /opt/omni/databases/vendor/cc/gpl/i386/linux/A.03.50/
                packet.Z
        /opt/omni/databases/vendor/cc/ibm/rs6000/aix-42/A.03.50/
                packet.Z
        /opt/omni/databases/vendor/cc/sco/i386/sco_sv/A.03.50/
                packet.Z
        /opt/omni/databases/vendor/cc/sco/i386/unixware/A.03.50/
                packet.Z
        /opt/omni/databases/vendor/cc/sequent/i386/dynix/A.03.50/
                packet.Z
        /opt/omni/databases/vendor/cc/sgi/mips/irix/A.03.50/packet.Z
        /opt/omni/databases/vendor/cc/sgi/mips/irix-62/A.03.50/
                packet.Z
        /opt/omni/databases/vendor/cc/siemens/r400/sinix/A.03.50/
                packet.Z
        /opt/omni/databases/vendor/cc/sun/sparc/solaris/A.03.50/
                packet.Z
        /opt/omni/databases/vendor/cc/sun/sparc/solaris-26/A.03.50/
                packet.Z
        /opt/omni/databases/vendor/cc/sun/sparc/sunos/A.03.50/
                packet.Z

what(1) Output:
        /opt/omni/databases/vendor/cc/hp/s800/hp-ux-1020/A.03.50/
                packet.Z:
                None
        /opt/omni/databases/vendor/cc/hp/s800/hp-ux-10/A.03.50/
                packet.Z:
                None
        /opt/omni/databases/vendor/cc/hp/s800/hp-ux-11/A.03.50/
                packet.Z:
                None
        /opt/omni/databases/vendor/cc/ncr/i386/mp-ras/A.03.50/
                packet.Z:
                None
        /opt/omni/databases/vendor/cc/dec/alpha/osf1-4/A.03.50/
                packet.Z:
                None
        /opt/omni/databases/vendor/cc/gpl/i386/linux/A.03.50/
                packet.Z:
                None
        /opt/omni/databases/vendor/cc/ibm/rs6000/aix-42/A.03.50/
                packet.Z:
                None
        /opt/omni/databases/vendor/cc/sco/i386/sco_sv/A.03.50/
                packet.Z:
                None
        /opt/omni/databases/vendor/cc/sco/i386/unixware/A.03.50/
                packet.Z:
                None
        /opt/omni/databases/vendor/cc/sequent/i386/dynix/A.03.50/
                packet.Z:
                None
        /opt/omni/databases/vendor/cc/sgi/mips/irix/A.03.50/
                packet.Z:
                None
        /opt/omni/databases/vendor/cc/sgi/mips/irix-62/A.03.50/
                packet.Z:
                None
        /opt/omni/databases/vendor/cc/siemens/r400/sinix/A.03.50/
                packet.Z:
                None
        /opt/omni/databases/vendor/cc/sun/sparc/solaris/A.03.50/
                packet.Z:
                None
        /opt/omni/databases/vendor/cc/sun/sparc/solaris-26/A.03.50/
                packet.Z:
                None
        /opt/omni/databases/vendor/cc/sun/sparc/sunos/A.03.50/
                packet.Z:
                None

cksum(1) Output:
        1535824785 11152455 /opt/omni/databases/vendor/cc/hp/s800/
                hp-ux-1020/A.03.50/packet.Z
        903497905 11208336 /opt/omni/databases/vendor/cc/hp/s800/
                hp-ux-10/A.03.50/packet.Z
        2271713999 11147314 /opt/omni/databases/vendor/cc/hp/s800/
                hp-ux-11/A.03.50/packet.Z
        2055934160 4172467 /opt/omni/databases/vendor/cc/ncr/i386/
                mp-ras/A.03.50/packet.Z
        3047406478 4949573 /opt/omni/databases/vendor/cc/dec/alpha/
                osf1-4/A.03.50/packet.Z
        2143153229 8627390 /opt/omni/databases/vendor/cc/gpl/i386/
                linux/A.03.50/packet.Z
        723479229 4217255 /opt/omni/databases/vendor/cc/ibm/rs6000/
                aix-42/A.03.50/packet.Z
        3759737747 4028813 /opt/omni/databases/vendor/cc/sco/i386/
                sco_sv/A.03.50/packet.Z
        3343189653 3941384 /opt/omni/databases/vendor/cc/sco/i386/
                unixware/A.03.50/packet.Z
        3819542767 4126913 /opt/omni/databases/vendor/cc/sequent/
                i386/dynix/A.03.50/packet.Z
        1089219669 5022182 /opt/omni/databases/vendor/cc/sgi/mips/
                irix/A.03.50/packet.Z
        2371282407 5922365 /opt/omni/databases/vendor/cc/sgi/mips/
                irix-62/A.03.50/packet.Z
        3937653808 4878331 /opt/omni/databases/vendor/cc/siemens/
                r400/sinix/A.03.50/packet.Z
        1711704483 4578857 /opt/omni/databases/vendor/cc/sun/sparc/
                solaris/A.03.50/packet.Z
        3292819385 4661017 /opt/omni/databases/vendor/cc/sun/sparc/
                solaris-26/A.03.50/packet.Z
        2190727103 6980139 /opt/omni/databases/vendor/cc/sun/sparc/
                sunos/A.03.50/packet.Z

Patch Conflicts: None

Patch Dependencies: None

Hardware Dependencies: None

Other Dependencies:
        If any newer SSP for the Cell Console is installed
        on your system, you must re-apply the SSP after
        installing this Cell Console patch.

        PHSS_28727:
        Release date: Available
        Id = HSLco40537 SR:H555009863
        Id = HSLco37193 SR:H555008807
        PHSS_28727 is required for these defect fixes.

        PHSS_28578:
        Release date: Available
        Id = HSLco40537 SR:H555009863
        PHSS_28578 is required for this defect fix.

        PHSS_28570:
        Release date: Available
        Id = HSLco40537 SR:H555009863
        Id = HSLco37193 SR:H555008807
        Bad catalog access messages are displayed without
        PHSS_28570.

        PHSS_28019:
        Release Date: Available
        Id = HSLco37193 SR:H555008807
        PHSS_28019 is required for this defect fix.

        PHSS_28017:
        Release Date: Available
        Id = HSLco40537 SR:H555009863
        Id = HSLco37193 SR:H555008807
        PHSS_28017 is required for these defect fixes.

Supersedes:
        PHSS_22038 PHSS_22850 PHSS_24660 PHSS_25956 PHSS_27595 PHSS_28222

Equivalent Patches:
        PHSS_28726:
        s700: 11.00 11.11 11.20
        s800: 11.00 11.11 11.20

Patch Package Size: 97360 KBytes

Installation Instructions:
        Please review all instructions and the Hewlett-Packard
        SupportLine User Guide or your Hewlett-Packard support terms
        and conditions for precautions, scope of license,
        restrictions, and, limitation of liability and warranties,
        before installing this patch.
        ------------------------------------------------------------
        1. Back up your system before installing a patch.

        2. Login as root.

        3. Copy the patch to the /tmp directory.

        4. Move to the /tmp directory and unshar the patch:

                cd /tmp
                sh PHSS_28725

        5a. For a standalone system, run swinstall to install the
            patch:

                swinstall -x autoreboot=true -x match_target=true \
                        -s /tmp/PHSS_28725.depot

        By default swinstall will archive the original software in
        /var/adm/sw/patch/PHSS_28725. If you do not wish to retain a
        copy of the original software, you can create an empty file
        named /var/adm/sw/patch/PATCH_NOSAVE.

        WARNING: If this file exists when a patch is installed, the
                 patch cannot be deinstalled. Please be careful
                 when using this feature.

        It is recommended that you move the PHSS_28725.text file to
        /var/adm/sw/patch for future reference.

        To put this patch on a magnetic tape and install from the
        tape drive, use the command:

                dd if=/tmp/PHSS_28725.depot of=/dev/rmt/0m bs=2k

Special Installation Instructions:
        PHSS_28725:
        NOTE!
        This Patch has to be installed on the Installation
        Server host.

        The User Interface must be redistributed to the client
        system(s) after the installation of the patch in order
        to get the fixes into effect.

        For distribution of the User Interface, refer to the
        OmniBackII Installation guide.

        Patch includes the following Site Specific Patches:
           SSPUX350_013
           SSPUX350_020
           SSPUX350_031
           SSPUX350_038
           SSPUX350_051
           SSPUX350_055
           SSPUX350_078
           SSPUX350_080
           SSPUX350_085
           SSPUX350_088
-----End of Document ID: PHSS_28725------------------------------------------


Document ID: PHSS_28723
Date Loaded: 20030404
      Title: s700_800 10.20 OV OB4.10 patch - SAP packet

Patch Name: PHSS_28723

Patch Description: s700_800 10.20 OV OB4.10 patch - SAP packet

Creation Date: 03/03/20

Post Date: 03/04/04

Hardware Platforms - OS Releases:
        s700: 10.20
        s800: 10.20

Products:
        OmniBackII A.04.10

Filesets:
        OMNIBACK-II.OMNI-SAP-P,A.04.10

Automatic Reboot?: No

Status: General Release

Critical: No

Path Name: /hp-ux_patches/s700_800/10.X/PHSS_28723

Symptoms:
        PHSS_28723:
        Id = HSLco39882 SR: H555009563
            Data Protector SAP R/3 integration does not work on
            SAP R/3 system with Oracle 9i.

        Id = HSLco40709 SR: H555009941
            Restore of sap tablespace on raw disk bigger than the
            one backed up falls into loop. Restore agent is then
            aborted due to inactivity by session manager.

        Id = HSLco40764 SR: H555009971
            During a SAP backup session, debug.log file is being
            filled with "Unknown state" messages.

        PHSS_28343:
        Id = HSLco36193 SR: H555008621
            Errors are reported in debug.log for files of size 0 and
            for missing function entry statements.

        Id = HSLco36404 SR: H555008642
            SAP BR tools 6.10 reports:

               "BR247E No Backup utility ID or ID longer than 16
               characters".

        Id = HSLco37193 SR: H555008807
            When backing up SAP integration with EMC split mirror
            functionality, not all the SAP files are backed up.

        Id = HSLco37210 SR: H555008812
            During raw device SAP restore following error is
            reported:

              "|Minor| From: OB2BAR_SAPREST<host> "" Time:<time>
               Error: Cannot open object <raw disk path>
               |20| Not a directory)."

        Id = HSLco37773 SR: H555008906
            During some backint queries following error is reported:

              "|Critical| From: OB2BAR<host> "" Time:<time>
               Failed to allocate memory.
               System error: |12| Not enough space"

        Id = HSLco37783 SR: H555008908
            When OmniBack II tries to backup nonexistent SAP redo
            logs, session ends as failed.

        Id = HSLco39552 SR: H555009439
            SAP backup on Linux, reports the following error:

            "Cannot get information on file
             '/sapmnt/SID/exe/brarchive ...' Error: 22."

        PHSS_27452:
        Id = HSLco35628 SR: H555008480
            Raw partition backup is not restored even though
            OmniBack II states that restore session is completed
            successfully.

        Id = HSLco35646 SR: H555008483
            Aborting SAP backup session results in executing new
            session.

        Id = JAGae25124 SR: 8606260802
            Session log files contains improper information when
            SAP backup fails.

        Id = HSLco35966 SR: H555008565
            "util_sap -APP" displays connection strings.

        PHSS_26887:
        Id = HSLco33261 SR: H555007380
            SAP integration on UNIX clients automatically passes
            "-u" option.

        Id = HSLco33795 SR: H555007605
            OmniBack II SAP integration is not supported on
            Compaq Tru64 operating system.

Defect Description:
        PHSS_28723:
        Id = HSLco39882
            Oracle Server Manager (svrmgrl) is obsoleted with
            Oracle 9i. sqlplus needs to be used instead.

        Resolution:
            Data Protector SAP R/3 integration works on SAP R/3
            system with Oracle 9i.

            Part of SSPUX410_067.

        Id = HSLco40709
            Size of data to be restored is mistakenly overwritten
            by disk size checking function.

        Resolution:
            Disk size checking function is changed in a manner that
            it properly calculates destination directory properties.

            Part of SSPUX410_064.

        Id = HSLco40764
            All information messages in switch.log, except #SUCCESS
            and #ERROR, are being treated as serious error.

        Resolution:
            Status of information messages is lowered from "error"
            to normal.

        PHSS_28343:
        Id = HSLco36193
            CheckFile checks marked error if parameter is null.
            Debugs are initialized after function entry is marked.

        Resolution:
            Error messages are not written to the debug.log file.

        Id = HSLco36404
            Set ID number searching is not strict enough and gets
            confused by new SAP BR tools format.

        Resolution:
            Stricter checking is applied to see if it really is
            backint ID.

            Part of SSPUX410_036.

        Id = HSLco37193
            In split mirror environment with huge SAP databases
            it can happen that the size of the message buffer
            OmniBack II uses is too small to receive complete list
            of SAP files to be backed up.

        Resolution:
            Setting the OB2IPCBUFSIZE environment variable in the
            /opt/omni/.omnirc file on Cell Server, R1 and R2 hosts,
            specifying the desired amount of memory to be used for
            the buffer solves the described problem.
            Please read the following instructions and make sure
            that the patches listed in "Other Dependencies" section
            (see below) are installed and the environment
            variable is set on Cell Server, R1 and R2 systems before
            running the backup!

            How to determine the buffer size?
            ---------------------------------

            N_obj: number of objects (files)
            N_fs: number of file systems
            N_lvmvg: number of volume groups
            N_dg: number of disk groups
            N_rdsk: number of rawdisks
            Obj: Object Name
            ObjBack: Object Backup Name
            MntPathLen: Path name on backup (R2) host
                         (example: /var/opt/omni/tmp/App_host)
            fsmnt: File System Mount Point
            fsdev: File System Device File
                         (example: /dev/dsk/|c0t1d1,lvol1|)
            vg: Volume group
                         (ex: /dev/vg01)
            dg: Disk group (VxVM) - dependence on mapfile
                         which is required for creating disk group
                         (example:/dev/vx/dsk/dg01)
            rdsk: Raw disk file name
                         (example: /dev/rdsk/c1t1d1)
            AvgLen_<xxx> average length of <xxx>

            There are two different buffers used:

            1. BSM <-> R1
            2. R1 <-> R2

            Calculating the BSM <-> R1 buffer size
            --------------------------------------
            MsgSize_BSM_R1 = N_obj * (AvgLen_Obj + 1 + MntPathLen)

            Calculating the R1 <-> R2 buffer size
            -------------------------------------
            MsgSize_R1_R2 =
              N_obj*(AvgLen_Obj+1+AvgLen_ObjBack) +
              N_fs*(AvgLen_fsmnt*2 + MntPathLen + AvgLen_fsdev*2)+
              N_lvmvg*(AvgLen_vg*2) + N_dg*(AvgLen_dg*2) +
              N_rdsk*(AvgLen_rdsk*2)

            Calculating the OB2IPCBUFSIZE value
            -----------------------------------
            OB2IPCBUFSIZE > max (MsgSize_BSM_R1, MsgSize_R1_R2)

            RESTORE NOTE:
            -------------
            If restore is started using the sapbda utility,
            the variable OB2IPCBUFSIZE must be exported to
            environment prior to starting sapbda.

            Known problems:
            ---------------
            If the calculated variable OB2IPCBUFSIZE is correctly
            set, but is still too small for the file list to fit
            into the message buffer, the session will fail with
            the following error seen in the report:

            BR295I Splitting mirror disks...
            BR280I Time stamp <time>
            BR279E Return code from '/opt/omni/lbin/ob2smbsplit
               /<sap_homedir_path>/.<filename>.lst': 2
            BR299E Split/resynchronization of mirror disks failed

            In this case the variable OB2IPCBUFSIZE must be
            recalculated to appropriate value. See above how to
            determine it.

            Part of SSPUX410_033.

        Id = HSLco37210
            OmniBack II ignores the following caution in the SAP
            specification:

              "Caution:By restoring raw partition to a different
              one, the <dest_dir> means directly the new raw
              partition, not the directory containing the special
              file."

        Resolution:
            Destination directory forming procedure is changed.

        Id = HSLco37773
            Some parts of structures for query are allocated but
            not released.

        Resolution:
            All allocated structures are released.

        Id = HSLco37783
            By design, whenever there are no objects backed up,
            OmniBack II ends session as failed.

        Resolution:
            Two new global variables have been introduced:

            a) SessSucessfullWhenNoObjectsBackedUp=0
            By setting this variable to 1 user can change the
            OmniBack II behavior in order to end the session as
            successful when there are no objects backed up.
            b) TreatScriptReturnAsNormal=<script return>
            By setting this variable to a certain number instructs
            OmniBack II to treat all the script returns equal to
            the specified number as normal.

        Id = HSLco39552
            'brbackup' and 'brarchive' are called with wrong
            parameters.

        Resolution:
            Parameters for 'brarchive' and 'brbackup' calls are
            corrected.

            Part of SSPUX410_050.

        PHSS_27452:
        Id = HSLco35628
            Incorrect function is used for raw partition restore.

        Resolution:
            Raw partition restore uses proper function.

            Part of SSPUX410_027.

        Id = HSLco35646
            Abort mechanism is implemented incorrectly.

        Resolution:
            Sapback aborts all the objects upon abort request from
            OmniBack II user.

        Id = JAGae25124
            Session log files contains improper information when
            SAP backup fails.

        Resolution:
            Log files contain proper information.

            Part of SSPUX410_023.

        Id = HSLco35966
            Connection string in printed in plain text format.

        Resolution:
            Connection string is encrypted before it is passed
            to GUI.

            Part of SSPUX410_025.

        PHSS_26887:
        Id = HSLco33261
            brbackup/brarchive is always started with "-u" option
            which displays logon information.

        Resolution:
            brbackup/brarchive options are passed in a file.

            Part of SSPUX410_014.

        Id = HSLco33795 SR: H555007605
            OmniBack II SAP integration is not supported on
            Compaq Tru64 operating system.

        Resolution:
            OmniBack II SAP integration is supported on
            Compaq Tru64 operating system.

SR:
        H555009971 H555009941 H555009563 H555008908 H555009439
        8606207021 H555008621 H555008812 H555008642 H555008643
        H555008906 H555008807 H555008480 8606244527 8606260802
        H555008483 H555008565 H555007605 H555007380

Patch Files:
        /opt/omni/databases/vendor/sap/gpl/i386/linux-60/A.04.10/
                packet.Z
        /opt/omni/databases/vendor/sap/hp/s800/hp-ux-1020/A.04.10/
                packet.Z
        /opt/omni/databases/vendor/sap/hp/s800/hp-ux-11/A.04.10/
                packet.Z
        /opt/omni/databases/vendor/sap/ibm/rs6000/aix-42/A.04.10/
                packet.Z
        /opt/omni/databases/vendor/sap/sun/sparc/solaris-26/A.04.10/
                packet.Z
        /opt/omni/databases/vendor/sap/dec/alpha/osf1-4/A.04.10/
                packet.Z
        /opt/omni/databases/vendor/sap/dec/alpha/osf1-4/A.04.10/
                require.dat

what(1) Output:
        /opt/omni/databases/vendor/sap/gpl/i386/linux-60/A.04.10/
                packet.Z:
                None
        /opt/omni/databases/vendor/sap/hp/s800/hp-ux-1020/A.04.10/
                packet.Z:
                None
        /opt/omni/databases/vendor/sap/hp/s800/hp-ux-11/A.04.10/
                packet.Z:
                None
        /opt/omni/databases/vendor/sap/ibm/rs6000/aix-42/A.04.10/
                packet.Z:
                None
        /opt/omni/databases/vendor/sap/sun/sparc/solaris-26/A.04.10/
                packet.Z:
                None
        /opt/omni/databases/vendor/sap/dec/alpha/osf1-4/A.04.10/
                packet.Z:
                None
        /opt/omni/databases/vendor/sap/dec/alpha/osf1-4/A.04.10/
                require.dat:
                None

cksum(1) Output:
        2964783613 966776 /opt/omni/databases/vendor/sap/gpl/i386/
                linux-60/A.04.10/packet.Z
        33902731 1329979 /opt/omni/databases/vendor/sap/hp/s800/
                hp-ux-1020/A.04.10/packet.Z
        4249096554 1322505 /opt/omni/databases/vendor/sap/hp/s800/
                hp-ux-11/A.04.10/packet.Z
        3393402820 1188666 /opt/omni/databases/vendor/sap/ibm/
                rs6000/aix-42/A.04.10/packet.Z
        3871788517 1239699 /opt/omni/databases/vendor/sap/sun/sparc/
                solaris-26/A.04.10/packet.Z
        3610240235 1872690 /opt/omni/databases/vendor/sap/dec/alpha/
                osf1-4/A.04.10/packet.Z
        1650591381 18 /opt/omni/databases/vendor/sap/dec/alpha/
                osf1-4/A.04.10/require.dat

Patch Conflicts: None

Patch Dependencies: None

Hardware Dependencies: None

Other Dependencies:
        If any newer SSP for the SAP is installed
        on your system, you must re-apply the SSP after
        installing this SAP patch.

        PHSS_28331:
        Release Date: Available
        Id = HSLco37193 SR:H555008807
        PHSS_28331 (or later) is required for this defect fix.

        PHSS_28232:
        Release Date: Available
        Id = HSLco37193 SR:H555008807
        Bad catalog access message is displayed without PHSS_28232
        (or later).

        PHSS_28341:
        Release Date: Available
        Id = HSLco37193 SR:H555008807
        PHSS_28341 (or later) is required for this defect fix.

        PHSS_27602:
        Release Date: Available
        Id = HSLco37193 SR:H555008807
        Id = HSLco37783 SR:H555008908
        PHSS_27602 (or later) is required for these defect fixes.

        PHSS_27456:
        Release Date: Available
        Id = HSLco33795 SR: H555007605
        PHSS_27456 (or later) is required for this enhancement.

Supersedes:
        PHSS_26887 PHSS_27452 PHSS_28343

Equivalent Patches:
        PHSS_28724:
        s700: 11.00 11.11 11.20
        s800: 11.00 11.11 11.20

Patch Package Size: 7800 KBytes

Installation Instructions:
        Please review all instructions and the Hewlett-Packard
        SupportLine User Guide or your Hewlett-Packard support terms
        and conditions for precautions, scope of license,
        restrictions, and, limitation of liability and warranties,
        before installing this patch.
        ------------------------------------------------------------
        1. Back up your system before installing a patch.

        2. Login as root.

        3. Copy the patch to the /tmp directory.

        4. Move to the /tmp directory and unshar the patch:

                cd /tmp
                sh PHSS_28723

        5a. For a standalone system, run swinstall to install the
            patch:

                swinstall -x autoreboot=true -x match_target=true \
                        -s /tmp/PHSS_28723.depot

        By default swinstall will archive the original software in
        /var/adm/sw/patch/PHSS_28723. If you do not wish to retain a
        copy of the original software, you can create an empty file
        named /var/adm/sw/patch/PATCH_NOSAVE.

        WARNING: If this file exists when a patch is installed, the
                 patch cannot be deinstalled. Please be careful
                 when using this feature.

        It is recommended that you move the PHSS_28723.text file to
        /var/adm/sw/patch for future reference.

        To put this patch on a magnetic tape and install from the
        tape drive, use the command:

                dd if=/tmp/PHSS_28723.depot of=/dev/rmt/0m bs=2k

Special Installation Instructions:
        PHSS_28723:
        NOTE!
        This Patch has to be installed on the Installation
        Server host.

        The OB2 SAP agent must be redistributed to the SAP
        client system(s) after the installation of the patch
        in order to get the fixes into effect.

        For distribution of the SAP agent, refer to
        the OmniBackII Installation guide.

        Patch includes the following Site Specific Patches:
           SSPUX410_014
           SSPUX410_023
           SSPUX410_025
           SSPUX410_027
           SSPUX410_033
           SSPUX410_036
           SSPUX410_050
           SSPUX410_064
           SSPUX410_067
-----End of Document ID: PHSS_28723------------------------------------------


Document ID: PHSS_28578
Date Loaded: 20030404
      Title: s700_800 10.X OV OB3.50 patch - SSEA packet

Patch Name: PHSS_28578

Patch Description: s700_800 10.X OV OB3.50 patch - SSEA packet

Creation Date: 03/03/24

Post Date: 03/04/04

Hardware Platforms - OS Releases:
        s700: 10.00 10.01 10.10 10.20
        s800: 10.00 10.01 10.10 10.20

Products:
        OmniBackII A.03.50

Filesets:
        OMNIBACK-II.OMNI-SSEA-P,A.03.50

Automatic Reboot?: No

Status: General Release

Critical: No

Path Name: /hp-ux_patches/s700_800/10.X/PHSS_28578

Symptoms:
        PHSS_28578:
        Id = HSLco37090 SR:H555008776
            SSEA LVM BC backup fails with:

              "[Critical] From: SSEA<hostname> "" Time:<time>
               Command "/usr/bin/raidscan -p <port>"
               failed with exit code 238.
               For details check the following log directories:
               Log file directory in operation:
               /var/opt/omni/log/<session_ID>/curlog<num>Log
               file directory for automatic storing:
               /var/opt/omni/log/<session_ID>/tmp<num>"

        Id = HSLco37449 SR:H555008860
            When resolving ssea reports all of its data for every
            single object to be backed up.

        Id = HSLco40537 SR:H555009863
            When backing up very large SAP databases with SSEA
            split mirror, backups can fail with error:

              "BR280I Time stamp <time>
               BR296I Split of mirror disks successful
               BR274E File /<sapdata_path>/system.data1 not found"

        PHSS_27591:
        Id = HSLco32398 SR:H555007043
            When there is a firewall between the application and
            the backup host, the split mirror backup fails.

        Id = HSLco32470 SR:H555007071
            Resolving performance is poor.

        Id = HSLco33214 SR:H555007361
            SSEA backup fails with:

              "[Major] From: SSEA<hostname> "" Time: <time>
               [224:106] Resolving of object <object_path> has
               failed. (Search for backup logical volume failed.)"

        Id = HSLco35074 SR:H555008259
            SSEA backup fails with:

              "[Critical] From: SSEA<hostname> "" Time:<time>
               Failed to get pair for LDEV <ldev#> in RAID <seq#>.
                        (Details unknown.)"

        Id = HSLco36105 SR:H555008599
            SSEA backup fails with:

              "[Critical] From: SSEA<host> <mailto:SSEA<host>
               "" Time:<time>
               Command "/usr/bin/pairdisplay -g" failed with exit
               code 242."

        Id = HSLco36476 SR:H555008656
            SSEA backup fails with:

              "[Major] From: SSEA<hostname> "" Time:<time>
               [224:106] Resolving of object <object_name> has
               failed. (Search for backup logical volume failed.)"

        Id = HSLco36975 SR:H555008750
            The SSEA SMB session on the backup host abnormally ends
            when trying to activate backup volume group after the
            paired LDEVs have been split.

        PHSS_26215:
        Id = HSLco32218 SR: H555006986
            Horc instance number is not configurable.

        Id = HSLco32253 SR: H555006993
            SSEA agent reports disks in SIMPLEX state although
            they are in PAIR state in HORCM.

        Id = HSLco32264 SR: H555006994
            OmniBack II SSEA Integration does not work with
            logical devices with XP LUN number greater than 128.

        Id = HSLco32274 SR: H555006996
            Performance of SSEA integration drastically decreases
            after the installation of PHSS_25817/PHSS_25818.

        PHSS_25817:
        Id = JAGad48627 SR:8606179403
            If preexec script fails OmniBack II by default just
            aborts the agent and exits. It does not run post-exec
            script or clean up.

        Id = NSMex04226
            Restore fails with:

              "[Major] From: SYMA<hostname> "" Time: <time>
               [223:325] Could not activate volume group
               /dev/sg_sap.

               [Major] From: SYMA<hostname> "" Time: <time>
               [223:363] Could not prepare mirror disks of object
               /sg_sap for backup.
               (Activation of volume group failed.)".

        Id = HSLco30300 SR:H555006603
            Split mirror backup fails with:

              "[Critical] From: SSEA<host> "" Time: <time>
                Command "/etc/horcmgr" failed with exit code 3.
                For details please check log directories:
                Log file directory in operation:
                        /var/opt/omni/log/yyyy-mm-dd-xx/curlogxx
                Log file directory for automatic storing:
                        /var/opt/omni/log/yyyy-mm-dd-xx/tmpxx".

        Id = HSLco31032 SR:H555006753
            Split mirror backup session fails with:

              "[Critical] From: SSEA<host> "" Time: <time>
               Failed to find T-VOL/R-Vol of LDEVs.

               [SseMapLdevToRdsk] Unable to found /dev/rdsks
               file for LDEV = <number>".

        Id = HSLco31434 SR:H555006835
            Unexpected close reading message from the agent on the
            Backup System (SSEA abnormally ends on R2).

        Id = HSLco30701 SR:H555006685
            Resolving fails on the Application host. The spt inq
            structure returns corrupted results.

        Id = HSLco31490 SR:H555006844
            SSEA integration backup fails with:

              "[Critical] From: SSEA<host_name> "" Time: <time>
                Command "/etc/horcmgr" failed with exit code 3.
               [Critical] From: SSEA<host_name> "" Time: <time>
                Failed to start RAID Manager instance.
                    (Command /etc/horcmgr failed.)".

        PHSS_24425:
        Id = NSMex04086
            Session status is "Completed/Failures" although there
            is no any indication of errors.

        Id = NSMex04209
            SSEA Integration backup fails with an error:

              "[Critical] From: SSEA<hostname> "" Time: <time>
                 Failed to find <volume/volume No.> of LDEVs.".

        Id = NSMex04216
            SSEA Integration backup reports the following warning:

              "[Warning] Cascading structure of BC pairs found
                (THIS IS UNSUPPORTED).".

        Id = NSMex04392
            SSEA Integration backup fails with an error:

              "Filesystem <path> could not be mounted.".

        Id = NSMex04267
            SSEA Integration backup fails with an error:

              "[61:1005] Got unexpected close from Split Mirror
               Agent.".

        Id = HSLco23886
            LVM Mirror (XP Campus Cluster) is not supported
            within OmniBack II SSEA Integration.

        PHSS_22436:
        Id = NSMex03360
            SSEA Integration split does not appear to mount some
            filesystems.

        Id = NSMex03700
            Disk resolving failed on Backup Host.

        Id = NSMex03717
            a) SSEA integration backup fails with an error:

               "[Major] From: SSEA<hostname> "" Time: <time>
                [224:106] Resolving of object "filename" has failed.
                    (Cannot find block device path name of a logical
                 volume)"

            b) SSEA Integration backup fails with an error:

               "[Major] From: SSEA<hostname> "" Time: <time>
                File system <filesystem> could
                not be mounted to . (Invalid filesystem type.)"

        Id = NSMex03482
            Disk synchronization messages are incorrect.

        Id = HSLco22201
            OmniBack II SSEA integration is not supported on Sun
            Solaris operating system.

        Id = NSMex03651
            Disk synchronization fails with:

              "[Critical] From: SSEA<hostname> "" Time: <time>
               [225:110] Mapping from LDEV to character device
                 file or disk failed for LDEV <dev> on
                 array <array>. (Unable to find character device
                 file for SureStoreE XP256 disk (LDEV))."

        Id = NSMex03673
            Backup fails with the following message:

              "[Critical] From: SSEA<hostname> "" Time: <time>
               Command "/usr/bin/pairdisplay -g" failed with
               exit code 242.".

        Id = NSMbb39679
            OmniBack II aborts Business Copy split mirror
            backup because one of the disks in a pair is in
            status COPY.

        Id = NSMex03547
            SSEA Agent intermittently fails to resolve objects.

        Id = NSMex03739
            Pre- and post-exec scripts return invalid exit status.

        Id = NSMex03913
            SSEA backup fails with the following message:

              "[Critical] From: SSEA<hostname> "" Time: <time>
               Command "/usr/bin/pairdisplay -g" failed with
               exit code 221.".

        Id = NSMex03960
            SSEA backup fails with the following error:

              "Failed to start RAID Manager instance.
               (Unable to find SureStoreE XP256 COMMAND device
                file.)".

        Id = NSMex03850
            Sometimes volumes cannot be mounted on JFS 3.3
            filesystem.

        Id = NSMex03749
            Mount function does not restore mount options.

        Id = NSMex03563
            Mounting of a filesystem fails.

        Id = NSMex03931
            OmniBack II SSEA Integration does not work on XP 512
            for LDEVs with XP LUN addresses above 128.

Defect Description:
        PHSS_28578:
        Id = HSLco37090
            If the LVM mirroring is done between two XP boxes with
            the BC configuration on the second XP box and the BC
            license present only on the second XP box, the raidscan
            command fails on the first XP box causing the session
            to fail.

        Resolution:
            BC license on the first XP is not needed. When
            executing the raidscan command, the SSEA session does
            not fail if the raidscan command fails, but just marks
            the rdsks and LDEVs from the first XP box with an
            error. The marked rdsks and LDEVs are skipped later in
            the session.

        Id = HSLco37449
            Extensive reporting is only needed in case of errors,
            so reporting data for every object can mean a lot of
            unwanted information, especially in big environments.

        Resolution:
            New environment variable is introduced:
            SSEA_RESOLVING_DISPLAY. Its default value is 1. Set
            it to 0 if you want to switch off extensive object
            data reporting.

        Id = HSLco40537
            In split mirror environment with very large SAP
            databases, it can happen that the size of the message
            buffer that OmniBack II uses is too small to fit in
            for the complete list of SAP files to be backed up.

        Resolution:
            New environment variable is introduced: OB2IPCBUFSIZE.
            In order to solve this problem, the buffer size can
            be increased by setting the OB2IPCBUFSIZE environment
            variable in the .omnirc file on CM, R1 and R2 hosts,
            specifying the desired amount of memory to be used
            for the buffer.
            Please read the following instructions and make sure
            that the patches listed in "Other Dependencies" section
            (see below) are installed and the environment
            variable is set on Cell Server, R1 and R2 systems before
            running the backup!

            How to determine the buffer size?
            ---------------------------------

            N_obj: number of objects (files)
            N_fs: number of file systems
            N_lvmvg: number of volume groups
            N_dg: number of disk groups
            N_rdsk: number of rawdisks
            Obj: Object Name
            ObjBack: Object Backup Name
            MntPathLen: Path name on backup (R2) host
                         (example: /var/opt/omni/tmp/App_host)
            fsmnt: File System Mount Point
            fsdev: File System Device File
                         (example: /dev/dsk/[c0t1d1,lvol1])
            vg: Volume group
                         (ex: /dev/vg01)
            dg: Disk group (VxVM) - dependence on mapfile
                         which is required for creating disk group
                         (example:/dev/vx/dsk/dg01)
            rdsk: Raw disk file name
                         (example: /dev/rdsk/c1t1d1)
            AvgLen_<xxx> average length of <xxx>

            There are two different buffers used:

            1. BSM <-> R1
            2. R1 <-> R2

            Calculating the BSM <-> R1 buffer size
            --------------------------------------
            MsgSize_BSM_R1 = N_obj * (AvgLen_Obj + 1 + MntPathLen)

            Calculating the R1 <-> R2 buffer size
            -------------------------------------
            MsgSize_R1_R2 =
              N_obj*(AvgLen_Obj+1+AvgLen_ObjBack) +
              N_fs*(AvgLen_fsmnt*2 + MntPathLen + AvgLen_fsdev*2)+
              N_lvmvg*(AvgLen_vg*2) + N_dg*(AvgLen_dg*2) +
              N_rdsk*(AvgLen_rdsk*2)

            Calculating the OB2IPCBUFSIZE value
            -----------------------------------
            OB2IPCBUFSIZE > max (MsgSize_BSM_R1, MsgSize_R1_R2)

            RESTORE NOTE:
            -------------
            If restore is started using the sapbda utility,
            the variable OB2IPCBUFSIZE must be exported to
            environment prior to starting sapbda.

            Part of SSPUX350_088.

        PHSS_27591:
        Id = HSLco32398
            OmniBack II selects by random the port to use and than
            checks if it is free. When there is a firewall between
            the application and the backup host, not all the ports
            can be used, but just those in a specified range.

        Resolution:
            Two environment variables are added to set the port
            range in .omnirc file that can be used by OmniBack II:

            SSEA_RM_PORT_LOW
            SSEA_RM_PORT_HIGH

        Id = HSLco32470
            In the resolving phase SSEA executes two ioscan
            commands in the SseXIoScanRdsk and ScsiIquiry
            functions. Since these two functions are called
            several times the resolving performance decreases,
            especially in big environments.

        Resolution:
            SSEA executes just one ioscan command in the
            SseXIoScanRdsk and ScsiIquiry functions. The ioscan
            output is cached into a buffer and parsed for
            information twice.

        Id = HSLco33214
            In case of non-XP rdsk, SSEA can not find the volume
            group belonging to this rdsk and resolving can not
            be done.

        Resolution:
            SSEA finds and checks all the rdsks belonging to an LDEV
            on the R2 side. Than it uses only those rdsks which are
            included in a volume group, in this way skips the non-XP
            rdsks.

        Id = HSLco35074
            When there are more than one smb sessions running
            simultaneously, horcm instances could be attached to
            the same command device.

        Resolution:
            SSEA retries the getldev() call for 10 times. The
            timeout before calling the getldev() API again is
            randomly set. From now on SSEA tries to attach up
            to 5 command devices if necessary.

        Id = HSLco36105
            A time out occurs on remote communication, and HORC
            manager fails to re-execute.

        Resolution:
            A new environment variable SSEA_RM_TIMEOUT is
            introduced. Its default value is 6000 milliseconds.

        Id = HSLco36476
            When mapping the LDEVs to the appropriate rdsks,
            rdsks statuses are not correctly updated.

        Resolution:
            Mapping is done correctly.

            Part of SSPUX350_083.

        Id = HSLco36975
            When the LDEVs belonging to a volume group are in PAIR
            status and the SSEA smb session is started on some of
            these LDEVs, the vgchange command on this volume group
            takes a long time. After splitting the disks on on the
            R2 side, the LDEVs included in the SMB session are in
            PSUS state, the rest of the LDEVs are still in PAIR
            state and vgchange command can not proceed, which
            causes the session to ends abnormally.

        Resolution:
            If the SMB_SPLIT_ENTIRE_VG environment variable is set
            to 1 in the .omnirc file on both hosts, then all the
            LDEV pairs included in the backup volume group are
            synchronized and split.

            Part of SSPUX350_084.

        PHSS_26215:
        Id = HSLco32218
            Horc instance number is not configurable.

        Resolution:
            Horc instance number can be configured using new
            environment variables, SSEA_RMINST_LOW and
            SSEA_RMINST_HIGH. When set in ${OMNI_HOME}/.omnirc
            file, these variables set instance number range. Default
            values for SSEA_RMINST_LOW and SSEA_RMINST_HIGH
            are 50 and 80, respectively.

            Part of SSPUX350_070.

        Id = HSLco32253
            Incorrect comparison of the strings causes incorrect
            state of the disks reported.

        Resolution:
            SSEA agent properly reports disk state.

        Id = HSLco32264
            SSEA agent creates invalid configuration files for
            logical devices exported to LUN's above 128.

        Resolution:
            New environment variable is introduced: SSEA_XP_PORTS.
            Setting the variable to the value "FC" in
            ${OMNI_HOME}/.omnirc file enables OmniBack II SSEA
            Integration to work properly with logical devices
            exported to XP LUN's greater than 128.

        Id = HSLco32274
            Multiple ioscan calls when extracting needed data
            cause bad performance.

        Resolution:
            Scripts for obtaining data needed by OmniBack II SSEA
            Integration are improved.

        PHSS_25817:
        Id = JAGad48627
            If pre-exec script fails, cleanup does not start
            post-exec script.

        Resolution:
            New environment variable is introduced. When
            SSEA_ALWAYS_POST_SCRIPT in .omnirc file on
            application host is set to 1, post-exec script
            is always executed.

        Id = NSMex04226
            Backup is made in SSEA/split mirror backup environment
            with the Application host in the cluster. When
            restoring object on the Backup host (R2), which is not
            in the cluster the cluster tag (-c y) from the
            Application host is also restored, so the volume group
            can not be activated properly.

        Resolution:
            By default the cluster tag on the Backup host (R2) is
            disabled with the "vgchange -q n -c n" command. To
            enable the cluster tag on Backup host, set the new
            environment variable SMB_CLUS_DEACT=1 in the
            /opt/omni/.omnirc file.

        Id = HSLco30300
            The command /etc/horcmgr fails if the command
            device is used by another split mirror session.

        Resolution:
            New environment variables are introduced
            SSEA_RM_RETRY and SSEA_RM_SLEEP.

            SSEA_RM_RETRY defines the number of retries.
            SSEA_RM_SLEE defines sleeping time in seconds,
            before new retry is started.

        Id = HSLco31032
            The resolving from LDEVs to rdsks on the backup host
            fails due to incorrect reporting of LDEVs to rdsks.

        Resolution:
            The resolving from LDEVs to rdsks is corrected.

        Id = HSLco31434
            SSEA agent on R2 does not read the number of rdsk
            from the R1. Bug is produced while fixing the
            NSMex04787 case on NT platform, but affected the
            SSEA agent on the HP-UX platform.

        Resolution:
            The correct number of strings is read from the SSEA
            agent on the R2 side.

        Id = HSLco30701
            The SCTL_InquiryDisk function returns empty or
            corrupted inq structure.

        Resolution:
            The ioctl system function writes its output directly
            to the inq structure. The "mapping from rdsks to LDEVs"
            and the ScsiInquiry are enhanced.

            Part of SSPUX350_057.

        Id = HSLco31490
            SSEA can not start the selected HORCMINST instance
            number. It is already started by another RaidManager
            process.

        Resolution:
            SSEA tries to start the instance with different
            instance number up to five times.

        PHSS_24425:
        Id = NSMex04086
            Message level of a resolving failure in XP environment
            is set to "Normal" instead of "Major".

        Resolution:
            Message level is corrected.

        Id = NSMex04209
            If backup devices are exported to more than one port
            and original devices have more than two mirrors, when
            session is started and two of these ports are used for
            that session, SSEA Integration detects more mirrors
            than it is allowed.

        Resolution:
            Parsing of raidscan() output is improved.

        Id = NSMex04216
            If there are two or three mirror disks to source
            disk, OmniBack II reports that cascading structure is
            found although cascading structure is present only
            when there are mirror disks to targer disk.

        Resolution:
            Searching for cascading structure is excluded as
            this feature is not supported with OmniBack II
            A.03.50 version.

        Id = NSMex04392
            Incorrect filesystem options are sent to R2 side.
            For HFS filesystems the entries in the mnttab file
            are not updated promptly.

        Resolution:
            Correct filesystem options are sent to R2 side.
            /etc/mnttab is promptly updated for HFS filesystem.

        Id = NSMex04267
            SSEA API fails after 60 seconds during the change of
            volume groups. SMB_TIMEOUT is hardcoded to 60 seconds.

        Resolution:
            SMB_TIMEOUT can be configured in .omnirc file for
            situations where the changing of volume groups takes
            more than one minute.

            Part of SSPUX350_037.

        Id = HSLco23886
            LVM Mirror (XP Campus Cluster) is not supported within
            OmniBack II SSEA Integration.

        Resolution:
            LVM Mirror (XP Campus Cluster) is supported within
            OmniBack II SSEA Integration.

        PHSS_22436:
        Id = NSMex03360
            XP256 Raid Manager's pairdisplay command returns
            invalid status which causes some raw disks to fail
            during resolving.

        Resolution:
            Status checking changed to ignore invalid status from
            pairdisplay command.

        Id = NSMex03700
            If there is a lot of backup objects (usually case with
            SAP databases) and these objects are placed in volume
            group with a lot of stripped disks, then the size of
            the internal message sent from SSEA-R1 to SSEA-R2 can
            overflow hardcoded 100k limit.

        Resolution:
            New message format reduces message size significantly.

            Part of the SSPUX350_007.

        Id = NSMex03717
            a) OmniBack II does not handle soft links correctly.

            b) SSEA integration backup does not work properly in
               case that a single session contains both filesystem
               and rawdisk objects.

        Resolution:
            Fixes are implemented in ssea.

            Part of the SSPUX350_007.

        Id = NSMex03482
            Disk synchronization failure reported as "Normal".

        Resolution:
            Message statuses are properly reported.

        Id = HSLco22201
            OmniBack II SSEA integration is not supported on Sun
            Solaris operating system.

        Resolution:
            OmniBack II SSEA integration is supported on Sun
            Solaris 7 and 8 operating systems.
            Please find the integration manual in the
            /usr/omni/bin/utilns directory after the patch is
            installed.

        Id = NSMex03651
            IPC buffer for communication between SSEA Agents on
            backup and application host is too small.

        Resolution:
            IPC buffer increased.

        Id = NSMex03673
            Pairdisplay command fails in ServiceGuard environment.

        Resolution:
            Hostname resolving is improved.

        Id = NSMbb39679
            OmniBack II does not treat status COPY as a valid
            status.

        Resolution:
            OmniBack II waits (for configurable timeout) for the
            second disk to change the status to PAIR.

            Environment variables are:

              SSEA_SYNC_SLEEP_TIME = <time in seconds>
              SSEA_SYNC_RETRY = <number of retries>

            Default values are 5 for SSEA_SYNC_SLEEP_TIME and
            10 for SSEA_SYNC_RETRY.

        Id = NSMex03547
            Resolving of objects fails if stat() function reports
            error for any entry in /etc/mnttab.

        Resolution:
            Irrelevant errors are skipped during the resolving.

        Id = NSMex03739
            Pre- and post-exec scripts return invalid exit status
            because of timing problem.

        Resolution:
            Environment variable OB2EXECTIMEOUT is introduced.
            Variable represents timeout (in seconds) after the end
            of pre- and post-exec script. Default value is 0.
            Recommended value is between 5 and 10 seconds.

        Id = NSMex03913
            Pairdisplay command fails if two sessions are started
            at the same time.

        Resolution:
            SSEA Agent correctly detects service port numbers
            availability.

        Id = NSMex03960
            SSEA Agent uses only those disks for which ioscan
            reports state CLAIMED. Backup fails due to a fact that
            some of the disks needed for session are in state SCAN.

        Resolution:
            Disks in state SCAN are reported as well as those in
            state CLAIMED.

        Id = NSMex03850
            Changes made for JFS 3.3 support cause mount problems
            on HP-UX 10.20 platform.

        Resolution:
            Code now properly works also for the HP-UX 10.20
            platform.

            Part of SSPUX350_016.

        Id = NSMex03749
            Filesystem is not mounted with the options that were
            used before split mirror backup was performed.

        Resolution:
            Command line mount command is used instead of mount
            function for vxfs filesystem.

        Id = NSMex03563
            Mount operation does not work properly on systems
            with Online JFS 3.3 installed.

        Resolution:
            Mount API uses proper arguments.

        Id = NSMex03931
            Invalid configuration files are created for LDEVs
            exported to LUN addresses above 128.

        Resolution:
            New environment variable SSEA_XP_PORTS is introduced.
            Its value has to be set to "FC" when using Fibre channel
            and LUN addresses greater than 128.

            Part of SSPUX350_032.

SR:
        H555009863 H555008776 H555008860 H555008656 B554000692
        H555007043 H555008599 H555007071 B554000869 B554000879
        H555007361 H555008750 H555008259 H555006993 H555006994
        H555006986 H555006996 H555006685 H555006753 8606179403
        H555006844 H555006835 H555006603 H555005488 H555005717
        H555005689 H555005681 H555004065 H555005289 H555003697
        B554000781 B554000676 B554000847 B554000829 H555004533
        H555004741 H555003490 H555003716 B554000521 B554000612
        H555003817 H555004474 B554000803 B554000491 H555004919

Patch Files:
        /opt/omni/databases/vendor/ssea/hp/s800/hp-ux-1020/A.03.50/
                packet.Z
        /opt/omni/databases/vendor/ssea/hp/s800/hp-ux-11/A.03.50/
                packet.Z
        /opt/omni/databases/vendor/ssea/sun/sparc/solaris-26/
                A.03.50/packet.Z
        /opt/omni/databases/vendor/ssea/sun/sparc/solaris-26/
                A.03.50/require.dat

what(1) Output:
        /opt/omni/databases/vendor/ssea/hp/s800/hp-ux-1020/A.03.50/
                packet.Z:
                None
        /opt/omni/databases/vendor/ssea/hp/s800/hp-ux-11/A.03.50/
                packet.Z:
                None
        /opt/omni/databases/vendor/ssea/sun/sparc/solaris-26/
                A.03.50/packet.Z:
                None
        /opt/omni/databases/vendor/ssea/sun/sparc/solaris-26/
                A.03.50/require.dat:
                None

cksum(1) Output:
        1343273602 2050307 /opt/omni/databases/vendor/ssea/hp/s800/
                hp-ux-1020/A.03.50/packet.Z
        3097561959 2059081 /opt/omni/databases/vendor/ssea/hp/s800/
                hp-ux-11/A.03.50/packet.Z
        3903783657 1550093 /opt/omni/databases/vendor/ssea/sun/
                sparc/solaris-26/A.03.50/packet.Z
        1830950196 19 /opt/omni/databases/vendor/ssea/sun/sparc/
                solaris-26/A.03.50/require.dat

Patch Conflicts: None

Patch Dependencies: None

Hardware Dependencies: None

Other Dependencies:
        If any newer SSP for the SSEA is installed
        on your system, you must re-apply the SSP after
        installing this SSEA patch.

        PHSS_28727:
        Release date: Late April
        Id = HSLco40537 SR:H555009863
        PHSS_28727 is required for this defect fix.

        PHSS_28725:
        Release date: Late April
        Id = HSLco40537 SR:H555009863
        PHSS_28725 is required for this defect fix.

        PHSS_28570:
        Release date: Available
        Id = HSLco40537 SR:H555009863
        Bad catalog access message is displayed without PHSS_28570.

        PHSS_28017:
        Release Date: Available
        Id = HSLco40537 SR:H555009863
        PHSS_28017 is required for this defect fix.

Supersedes:
        PHSS_22436 PHSS_24425 PHSS_25817 PHSS_26215 PHSS_27591

Equivalent Patches:
        PHSS_28579:
        s700: 11.00 11.11 11.20
        s800: 11.00 11.11 11.20

Patch Package Size: 5590 KBytes

Installation Instructions:
        Please review all instructions and the Hewlett-Packard
        SupportLine User Guide or your Hewlett-Packard support terms
        and conditions for precautions, scope of license,
        restrictions, and, limitation of liability and warranties,
        before installing this patch.
        ------------------------------------------------------------
        1. Back up your system before installing a patch.

        2. Login as root.

        3. Copy the patch to the /tmp directory.

        4. Move to the /tmp directory and unshar the patch:

                cd /tmp
                sh PHSS_28578

        5a. For a standalone system, run swinstall to install the
            patch:

                swinstall -x autoreboot=true -x match_target=true \
                        -s /tmp/PHSS_28578.depot

        By default swinstall will archive the original software in
        /var/adm/sw/patch/PHSS_28578. If you do not wish to retain a
        copy of the original software, you can create an empty file
        named /var/adm/sw/patch/PATCH_NOSAVE.

        WARNING: If this file exists when a patch is installed, the
                 patch cannot be deinstalled. Please be careful
                 when using this feature.

        It is recommended that you move the PHSS_28578.text file to
        /var/adm/sw/patch for future reference.

        To put this patch on a magnetic tape and install from the
        tape drive, use the command:

                dd if=/tmp/PHSS_28578.depot of=/dev/rmt/0m bs=2k

Special Installation Instructions:
        PHSS_28578:
        NOTE!
        This patch has to be installed on the Installation
        Server host.

        The OB2 SSEA agent must be redistributed to the SSEA
        client system(s) after the installation of the patch
        in order to get the fixes into effect.

        For distribution of the SSEA agent, refer to
        the OmniBackII Installation guide.

        Patch includes the following Site Specific Patches:
           SSPUX350_007
           SSPUX350_016
           SSPUX350_032
           SSPUX350_037
           SSPUX350_057
           SSPUX350_070
           SSPUX350_083
           SSPUX350_084
           SSPUX350_088
-----End of Document ID: PHSS_28578------------------------------------------


Document ID: PHSS_27297
Date Loaded: 20030404
      Title: s700_800 10.20 OV ITO6.0X Solaris Agent Patch A.06.11

Patch Name: PHSS_27297

Patch Description: s700_800 10.20 OV ITO6.0X Solaris Agent Patch A.06.11

Creation Date: 03/04/03

Post Date: 03/04/04

Hardware Platforms - OS Releases:
        s700: 10.20
        s800: 10.20

Products:
        OpenView IT/Operations 6.0

Filesets:
        OVOPC-CLT.OVOPC-SOL-CLT,A.06.00

Automatic Reboot?: No

Status: General Release

Critical: No

Path Name: /hp-ux_patches/s700_800/10.X/PHSS_27297

Symptoms:
        PHSS_27297:
        - SR: H555003664
          option "-" of dmesg is not supported any more
        - SR: H555006719
          If the agent is running as a non-root user, when the
          management server processes are restarted, the agent has
          to be restarted, else messages are buffered.
        - SR: H555006934
          After agent installation internal messages are sent with
          wrong codeset.
        - SR: H555008352
          ITO agent installation check on Solaris 2.9
        - SR: 8606213476
          The distribution to nodes may hang or fail. This is more
          likely to happen while distributing to Windows NT/2000
          nodes rather than on UNIX nodes. On Windows NT/Windows
          2000 nodes the control agent may produces a Dr. Watson
          error.
        - SR: 8606217814
          If customer calls agent init script manually from
          non posix shell it will fail.So shell definition need
          to be added.
        - SR: 8606222554
          Certain policies in VPW do not work as expected, for
          example:
          VP_WIN-WINS-FwdAllInformation
          VP_WIN-WINS-FwdAllWarnError
          VP_WIN-DHCPCl_FwdAllInfo
          VP_WIN-DHCPCl_FwdAllWarnError
          This problem can also occur for VPO during condition
          matching. Matching the application and object attributes
          is now case sensitive. For example, a message with
          application "TEST" is matched but application "tEST" is
          unmatched.
        - SR: 8606227840
          Variables in the template default message key are not
          resolved for unmatched messages.
        - SR: 8606233602
          If using a pattern like '<*.prefix>ERR<*.suffix>', the
          prefix variable will get assigned a wrong text if it
          should be empty.
        - SR: 8606242614
          Messages are incorrectly suppressed by the logfile
          encapsulator if "suppress identical output messages" is
          specified and the messages differ only in the values of
          <$LOGFILE> and/or <$LOGPATH>.
        - SR: 8606244523
          When using the syntax <`script`> in the logfile template
          and the script returns the same logfile name twice, the
          opcle will abort.
        - SR: B555007980
          Local automatic actions are started immediately, even
          though the agent MSI is enabled in divert mode and the
          Immediate Local Automatic Action box is not checked.
        - SR: B555008220
          The <$MSG_TIME_CREATED> variable is not substituted in
          the message template.
        - SR: B555008838
          The event correlation engine creates a "Time cannot go
          backwards" error if the system is very busy.
        - SR: B555009745
          The template default of the object field of a monitor
          template is not used.
        - SR: B555010620
          Some messages are missing in the Japanese message
          catalogue. You get a Cannot generate message error.
        - SR: B555010966
          A message key relation containing <*> does not always
          match message keys correctly. This results in messages
          not being acknowledged when they should.
        - SR: B555011184
          opcagt fails to start opcctla if it is started as
          ./opcagt and /opt/OV/bin/OpC is not in the search PATH
        - SR: B555011594
          The original message text of a logfile encapsulator
          message is wrong if <$LOGPATH> or <$LOGFILE> is used.
        - SR: B555011638
          The pattern matching cannot match the new line
          character(s) of multiline messages.
        - SR: B555011979
          The pattern matching hangs if only single byte Japanese
          HANKAKU KANA characters are used.
        - SR: B555011990
          The ECS event log (ecevilg) has an invalid time
          difference to the next message which can cause the ECS
          simulator to hang or appear to hang when loading an event
          log file with such values.
        - SR: B555012210
          ECS circuit using reset on unless node causes opceca to
          abort.
        - SR: B555012929
          If you run opcdista from commandline, you don't get any
          useful messages, only the internal status letters.
          For supportability, it would be better to have
          some explicit status and error reporting.
        - SR: B555013371
          Sometimes the new scheduled action template configuration
          is not loaded after a distribution. Instead, the old
          scheduled actions are still started.
        - SR: B555013435
          The message agent opcmsga hangs unpredictably. This is
          more likely to happen on systems with a very high ICMP
          traffic.
        - SR: B555013495
          In Japanese environments programs using the agent APIs
          can fail with errors on invalid or incompatible codesets.
        - SR: B555013620
          Support for pmd's "u" option needed in opctrapi: use the
          UDP packet's address as source of the trap.
        - SR: B555013719
          Message agent doesn't stop message buffering when the
          management server is available again after a network
          outage, fixed DNS problem or similar.
          This can happen when the agent restarts/the machine
          reboots during the network problem occured.
        - SR: B555013794
          The current directory should be removed from the agent's
          environment PATH. That way only files can be executed
          that are either specified with the full path or the path
          is explicitly specified in the PATH.
        - SR: B555013891
          In MoM environments, opcmsga does not return action
          responses to SECONDARY managers, if their name is not
          resolveable.
        - SR: B555014093
          opcmona may crash (UNIX) or doesn't process all SCHEDULE
          templates (Windows) when using SCHEDULE templates.
        - SR: B555014132
          During a distribution the agent may report an error like:
          ITO responsible manager configuration. (OpC30-1203)
          Cannot open file \usr\OV\tmp\OpC\cfgchg.
          System Error Number: 13 (d) - The data is invalid.
           (OpC20-63)
        - SR: B553000162
          After opcagt -stop, opcagt -status does tell that the
          control agent does not run although it is running and
          sometimes you get following error in the message browser:
          ouput of kill -0 differs from internal pids-table for
          index <number> (OpC30-1094)

        :
        - SR: H555005793
          after A.06.06 opcctla might core dump during
          distribution
        - SR: H555005720
          vcs_monitor.sh script is missing from the NCS comm package
        - SR: H555005837
          Japanese catalogs are missing in A.06.06 patch
        - SR: H555004515
          Subagent cannot be stopped on Solaris 8
        - SR: B555010879
          opctrapi aborts during template distribution if
          conditions with the 'Suppress Identical Output Messages'
          features are used.
        - SR: B555010899
          opcdista requests distribution data from a wrong manager
          if there is a secondary manager with the same short
          hostname than the appropriate primary manager.
        - SR: B555010948
          Nested alternatives were not handled correctly in the
          pattern matching algorithm, e.g. the pattern '[a|b]c|d'
          was handled like '[a|b|d]c'.
        - SR: B555010980
          Traps without a SNMP variable are not matched because
          server patch adds an extra attribute to the template.

        :
        - SR: 8606180891
          The template default for the service name is not used.
        - SR: 8606181988
          The event interceptor doesn't forward on
          "forward unmatched" if a "supress unmatched" condition
          is used in a second template
        - SR: B555010341
          Agent sometimes does not start automatically after reboot
          while manual start works fine.
        - SR: 8606146160
          Veritas Cluster was not supported on VPO for Sun
          Solaris

        PHSS_23824:
        - The VPO A.06.03 patches for HP-UX and Solaris
          do not work as expected in firewall environments:
          While server port restrictions are still regarded,
          client-side port restrictions are ignored.
        - The event correlation process opcecm might crash
          after processing several annotation nodes
         - HPlwdce Kill(shutdown) scripts are missing.

        PHSS_22885:
         - Changes were required for the security add-on product
           VantagePoint Advanced Security.
         - The IT/O Agent API call opcagtmsg_send()
           might leak memory if the opcmsgi isn't running.
         - The opctrapi might abort with OpC30-104
         - disk_mon.sh returns invalid values if the bdf command
           returns more than one line output for a filesystem
           (e.g. if the filesystem name exceeds its column width)
         - ITO Agent might hang during ITA synchronisation
           when transferring bigger files (>0.5 MB) from several
           nodes to the ITO server at the same time
         - swap_util monitoring does not work on Solaris 8
         - in Japanese environment.
         - Problems with allowed port range.
         - In case of an error the ITO Agent might hang
           during startup without terminating

        PHSS_22255:
        - Agent needs better handling for firewall environments.
        - When executing large numbers of autoactions, some of them
          were staying in 'running' state.
        - opctrapi aborts after getting traps with unresolvable IP
          address.
        - The handling of '\' was different in the pattern
          definition and the "matching pattern".
        - the opcmsga reported Message Receiver service not
          registered even if the connection to the server was ok
        - Running a VBScript-tool on a unix node gave a strange
          error message
        - if buffer file size limitation is enabled the agent may
          discard low-severity messages even if there is still
          space in the buffer file
        - swap_util template did not work on Solaris 8
          in Japanese environment

Defect Description:
        PHSS_27297:
        - SR: H555006719
          When a communication to a message receiver fails, the
          message agent starts buffering messages. It periodically
          checks if a server is alive by sending it ICMP packets.
          If the server cannot be reached with ICMP packets, no RPC
          communication is attempted. Sending ICMP packets is not
          possible when the agent is running as a non-root user, so
          the sending function cannot actually send anything.
          Therefore we also never receive any replies and the
          message agent will buffer messages forever. To fix this,
          the internal state of the message agent is updated after
          we tried to send an ICMP packet if the agent is running
          as a non-root user.
        - SR: H555006934
          It is necessary to check nodeinfo file and then set
          appropriate language (same like in nodeinfo) in start-up
          script to start agent.
          There are not all releases known where this defect should
          be included.This should be checked from time to time.
        - SR: 8606213476
          While the agent receives several RPC calls, like "Start
          Distribution", "Execute Action" or "Set Primary Manager"
          in parallel, it may happen that the call results in a
          conflict within the control agent, which causes the
          control agent to bring a Dr. Watson window.
          This conflict can also occur on UNIX but the control
          agent doesn't die, rather the RPC request may fail.
          With this version the RPC calls which could cause
          conflicts are serialised.
        - SR: 8606217814
          To avoid problems with different shells an interpreting
          shell has been defined explicitly.
        - SR: 8606222554
          The condition test for the message attributes
          application, object and message group are always done
          case sensitive, therefore a message with the application
          "TEST" matches but "tEST" does not match.
          With this patch an opcinfo flag is introduced, which
          allows to switch between case sensitive and case
          insensitive check.
          flag : OPC_COND_FIELD_ICASE
          type : boolean
          default: FALSE
          By setting this to true the policies mentioned above will
          work.
        - SR: 8606242614
          The variables <$LOGFILE> and <$LOGPATH> were replaced
          after the suppression rules were evaluated. Therefore the
          comparison did not use the actual logfile name or path,
          but compared the string "<$LOGFILE>" or "<$LOGPATH>".
        - SR: 8606244523
          The opcle aborts when a <`script`> returns a logfile name
          twice. This is because of referencing and handling the
          same file twice.
          To fix this, the opcle checks whether the same logfile
          has been returned already and when adding to the internal
          list, each logfile gets added exactly once.
        - SR: B555010966
          The processing of the key relation is wrong for the log
          file encapsulator. The problem is that all unresolved
          entries followed by a resolved entry are removed.
          Other unresolved entries are kept as is.
        - SR: B555011184
          The working directory for the ITO agent was changed
          from /opt/OV/bin/OpC to /tmp to avoid problems if
          the agent is running in an MC/SG environment.
        - SR: B555011638
          The pattern matching could not match the new line
          character(s) of multi line messages. The following
          changes have been made to allow this:
          It is now possible to use ^M (\r) as a field separator.
          A new pattern </> was introduced to match any number of
          line breaks (UNIX style \n or NT style \r\n). <n/> will
          match exactly n line breaks, for example <1/> will match
          exactly one line break.
          This change works only for sources that already can
          create multi line messages (for example opcmsg or NT
          event log), it does not allow multi line logfile
          encapsulation.
          This change requires changes for management server and
          agent. Therefore a patch for the management server and
          a patch for the agent is required to use the new
          functionality.
        - SR: B555012210
          Linked with new ECS runtime library that contains
          a fix for this problem.
        - SR: B555012929
          The opcdista communicates with the opcctla process via
          stdin/stdout so if you run it from commandline, you only
          see the status letters but don't know what they mean.
          The new '-v' option prints more output, e.g.:
              $ ./opcdista -v
              0 - No distribution data available.
        - SR: B555013435
          One thread tried to read from a socket while another
          thread closed it. This could happen due to missing
          locking of global data. This data is now guarded by a
          mutex.
        - SR: B555013495
          When tracing was added to the API functions a necessary
          NLS initialisation was not done. This problem was
          introduced only by the A.06.10 patches for HPUX.
        - SR: B555013620
          NNM 6.2 introduced an event option to pmd - "u". This
          option specifies to prefer the IP address in an SNMPv1
          trap's UDP header over the contents of the SNMPv1 trap
          PDU's agent_addr field.
          A new opcinfo variable OPC_USE_UDP_AS_TRAP_SOURCE was
          added for opctrapi. If set to TRUE, opctrapi will use the
          UDP address instead of the agent_addr.
        - SR: B555013719
          Message agent remains in buffering mode even when
          the management server is available again.
          The reason is that the agent wasn't able to resolve
          the management server name to an IP address at startup
          and the agent doesn't try again during runtime.
          This has been fixed by checking for a resolvable name
          every time a message should be buffered till the name can
          be resolved, after this the normal checkalive mechanism
          which handles buffered message takes place.
        - SR: B555013891
          Even if the IP address of the management server was
          specified in the mgrconf file, it was not used except for
          the primary manager. This behaviour was changed to give
          the mgrconf file precedence over name resolution.
        - SR: B555014093
          opcmona may crash (UNIX) or doesn't process all SCHEDULE
          templates (Windows) when using SCHEDULE templates.
          This can occur when there are only spaces in
          one of the schedule fields (Minute, Hour, Day of the
          Month, Month, Year, Day of the Week).
          You can verify this by going to the conf/OpC directory on
          the node and doing an opcdcode monitor. When
          there are entries like WEEKDAY " " the problem can occur.
          Now the monitor agent treats sequences of spaces like
          an empty string that is a wildcard and uses all valid
          values in the possible range.
          For WEEKDAY this is 0-6.
        - SR: B555014132
          During a distribution the agent may report error number
          OPC30-1203/OPC20-63 when trying to access the cfgchg
          file.
          The cause for this problem is that there are several
          processes trying to get exclusive access to this file
          at the same time. The problem has been fixed by doing a
          retry for 10 times in case the error should occur with a
          delay of one second.

        for SR's not listed in this section please see
        the list of symptoms

        :
        check the list of the symptoms
        Resolution:
        check the list of the symptoms

        :
         NSMbb40742
        - SR: B555010341
          When the process ID of the 'opcctla -start' is the same
          as of the running opcctla before the shutdown, the
          internal logic concluded that the agent is already
          running and did not start up the subprocesses.

        for all other defects not listed in this section please see
        the list of symptoms
        Resolution:
        check the list of the symptoms

        PHSS_23824:
        check the list of the symptoms
        Resolution:
        check the list of the symptoms

        PHSS_22885:
        check the list of the symptoms
        Resolution:
        check the list of the symptoms

        PHSS_22255:
        check the list of the symptoms
        Resolution:
        check the list of the symptoms

SR:
        H555008352 H555006934 H555006719 H555005837 H555005793
        H555005720 H555005007 H555004515 H555003664 H555003507
        H555003505 H555003466 H555003277 H555002616 B555014132
        B555014093 B555013891 B555013794 B555013719 B555013620
        B555013495 B555013435 B555013371 B555012929 B555012210
        B555011990 B555011979 B555011638 B555011594 B555011505
        B555011184 B555010980 B555010966 B555010948 B555010899
        B555010879 B555010620 B555010341 B555010079 B555009745
        B555009212 B555009155 B555009152 B555008838 B555008314
        B555008220 B555007980 B555007752 B555007709 B555007602
        B555007426 B555006890 B555006267 B553000162 8606244523
        8606242614 8606233602 8606227840 8606222554 8606217814
        8606213476 8606181988 8606180891 8606146160 8606141434
        8606137088

Patch Files:
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/opc_pkg.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/install/opcrclchk
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/install/opcrdschk
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/install/opcrndchk
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/install/opcroschk
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/install/opcrverchk
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/install/opcrinst
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/install/opcnsl
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/ana_disk.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/cpu_mon.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/disk_mon.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/last_logs.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/mailq_l.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/proc_mon.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/sh_procs.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/swap_mon.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/vp_chk.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/mondbfile.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/dist_mon.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/ssp_chk.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/vcs_monitor.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/opcfwtmp.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/actions/mailq_pr.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/actions/st_inetd.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/actions/st_syslogd.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/actions/st_mail.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/actions/dist_del.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/cmds/opcdf.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/cmds/opclpst.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/cmds/opcps.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/cmds/E10000Log.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/cmds/ssp_config.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/opc_pkg.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/install/opcrclchk
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/install/opcrdschk
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/install/opcrndchk
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/install/opcroschk
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/install/opcrverchk
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/install/opcrinst
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/install/opcnsl
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/ana_disk.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/cpu_mon.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/disk_mon.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/last_logs.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/mailq_l.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/proc_mon.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/sh_procs.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/swap_mon.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/vp_chk.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/mondbfile.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/dist_mon.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/ssp_chk.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/vcs_monitor.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/opcfwtmp.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/actions/mailq_pr.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/actions/st_inetd.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/actions/st_syslogd.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/actions/st_mail.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/actions/dist_del.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/cmds/opc_sec_v.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/cmds/opcdf.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/cmds/opclpst.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/cmds/opcps.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/cmds/E10000Log.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/cmds/ssp_config.sh.Z
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/AgentPlatform
        /var/opt/OV/share/tmp/OpC_appl/new_syslog/C/TEMPLATES/
                LOGFILE/logfile.dat
        /var/opt/OV/share/tmp/OpC_appl/new_syslog/C/new_sysl.idx
        /var/opt/OV/share/tmp/OpC_appl/new_syslog/ja_JP.SJIS/
                TEMPLATES/LOGFILE/logfile.dat
        /var/opt/OV/share/tmp/OpC_appl/new_syslog/ja_JP.SJIS/
                new_sysl.idx
        /opt/OV/OpC/examples/progs/Makef.solaris
        /opt/OV/OpC/examples/progs/Makef.solarisdce

what(1) Output:
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/opc_pkg.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/install/opcrclchk:
                HP OpenView VantagePoint for Sun Solaris A.06.11 (07
                        /09/02)
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/install/opcrdschk:
                HP OpenView VantagePoint for Sun Solaris A.06.11 (07
                        /09/02)
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/install/opcrndchk:
                HP OpenView VantagePoint for Sun Solaris A.06.11 (07
                        /09/02)
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/install/opcroschk:
                HP OpenView VantagePoint for Sun Solaris A.06.11 (07
                        /09/02)
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/install/opcrverchk:
                HP OpenView VantagePoint for Sun Solaris A.06.11 (07
                        /09/02)
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/install/opcrinst:
                HP OpenView VantagePoint for Sun Solaris A.06.11 (07
                        /09/02)
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/install/opcnsl:
                HP OpenView VantagePoint for Sun Solaris A.06.11 (07
                        /09/02)
                stdio.h 1.39 95/12/04 SMI
                feature_tests.h 1.7 94/12/06 SMI
                va_list.h 1.6 96/01/26 SMI
                types.h 1.38 95/11/14 SMI
                isa_defs.h 1.7 94/10/26 SMI
                machtypes.h 1.9 94/11/05 SMI
                select.h 1.10 92/07/14 SMI
                time.h 2.47 95/08/24 SMI
                time.h 1.23 95/08/28 SMI
                siginfo.h 1.36 95/08/24 SMI
                machsig.h 1.10 94/11/05 SMI
                socket.h 1.15 95/02/24 SMI
                netconfig.h 1.13 95/02/24 SMI
                sockio.h 1.11 93/10/26 SMI
                ioccom.h 1.10 92/07/14 SMI
                in.h 1.4 93/07/06 SMI
                stream.h 1.56 94/09/28 SMI
                vnode.h 1.54 98/10/09 SMI
                t_lock.h 1.42 94/11/02 SMI
                machlock.h 1.14 94/10/20 SMI
                dki_lkinfo.h 1.8 93/05/03 SMI
                dl.h 1.13 93/08/18 SMI
                sleepq.h 1.17 94/07/29 SMI
                turnstile.h 1.27 94/10/27 SMI
                param.h 1.34 95/11/05 SMI
                unistd.h 1.24 95/08/24 SMI
                pirec.h 1.11 93/12/20 SMI
                mutex.h 1.14 94/07/29 SMI
                rwlock.h 1.3 94/07/29 SMI
                semaphore.h 1.4 94/07/29 SMI
                condvar.h 1.6 94/07/29 SMI
                cred.h 1.18 94/12/04 SMI
                uio.h 1.21 94/04/22 SMI
                seg_enum.h 1.1 93/04/03 SMI
                poll.h 1.19 94/08/31 SMI
                strmdep.h 1.8 92/07/14 SMI
                byteorder.h 1.9 94/01/04 SMI
                netdb.h 1.17 97/12/23 SMI
                types.h 1.38 95/11/14 SMI
                feature_tests.h 1.7 94/12/06 SMI
                isa_defs.h 1.7 94/10/26 SMI
                machtypes.h 1.9 94/11/05 SMI
                select.h 1.10 92/07/14 SMI
                time.h 2.47 95/08/24 SMI
                time.h 1.23 95/08/28 SMI
                siginfo.h 1.36 95/08/24 SMI
                machsig.h 1.10 94/11/05 SMI
                types.h 1.38 95/11/14 SMI
                feature_tests.h 1.7 94/12/06 SMI
                isa_defs.h 1.7 94/10/26 SMI
                machtypes.h 1.9 94/11/05 SMI
                select.h 1.10 92/07/14 SMI
                time.h 2.47 95/08/24 SMI
                time.h 1.23 95/08/28 SMI
                siginfo.h 1.36 95/08/24 SMI
                machsig.h 1.10 94/11/05 SMI
                unistd.h 1.33 95/08/28 SMI
                unistd.h 1.24 95/08/24 SMI
                utsname.h 1.24 95/07/14 SMI
                errno.h 1.13 95/09/10 SMI
                errno.h 1.15 95/01/22 SMI
                in.h 1.4 93/07/06 SMI
                stream.h 1.56 94/09/28 SMI
                vnode.h 1.54 98/10/09 SMI
                t_lock.h 1.42 94/11/02 SMI
                machlock.h 1.14 94/10/20 SMI
                dki_lkinfo.h 1.8 93/05/03 SMI
                dl.h 1.13 93/08/18 SMI
                sleepq.h 1.17 94/07/29 SMI
                turnstile.h 1.27 94/10/27 SMI
                param.h 1.34 95/11/05 SMI
                pirec.h 1.11 93/12/20 SMI
                mutex.h 1.14 94/07/29 SMI
                rwlock.h 1.3 94/07/29 SMI
                semaphore.h 1.4 94/07/29 SMI
                condvar.h 1.6 94/07/29 SMI
                cred.h 1.18 94/12/04 SMI
                uio.h 1.21 94/04/22 SMI
                seg_enum.h 1.1 93/04/03 SMI
                poll.h 1.19 94/08/31 SMI
                strmdep.h 1.8 92/07/14 SMI
                byteorder.h 1.9 94/01/04 SMI
                socket.h 1.15 95/02/24 SMI
                netconfig.h 1.13 95/02/24 SMI
                sockio.h 1.11 93/10/26 SMI
                ioccom.h 1.10 92/07/14 SMI
                netdb.h 1.15 96/05/29 SMI
                types.h 1.38 95/11/14 SMI
                feature_tests.h 1.7 94/12/06 SMI
                isa_defs.h 1.7 94/10/26 SMI
                machtypes.h 1.9 94/11/05 SMI
                select.h 1.10 92/07/14 SMI
                time.h 2.47 95/08/24 SMI
                time.h 1.23 95/08/28 SMI
                siginfo.h 1.36 95/08/24 SMI
                machsig.h 1.10 94/11/05 SMI
                unistd.h 1.33 95/08/28 SMI
                unistd.h 1.24 95/08/24 SMI
                socket.h 1.15 95/02/24 SMI
                netconfig.h 1.13 95/02/24 SMI
                sockio.h 1.11 93/10/26 SMI
                ioccom.h 1.10 92/07/14 SMI
                ipc.h 1.15 94/09/03 SMI
                un.h 1.8 92/07/14 SMI
                netdb.h 1.15 96/05/29 SMI
                in.h 1.4 93/07/06 SMI
                stream.h 1.56 94/09/28 SMI
                vnode.h 1.54 98/10/09 SMI
                t_lock.h 1.42 94/11/02 SMI
                machlock.h 1.14 94/10/20 SMI
                dki_lkinfo.h 1.8 93/05/03 SMI
                dl.h 1.13 93/08/18 SMI
                sleepq.h 1.17 94/07/29 SMI
                turnstile.h 1.27 94/10/27 SMI
                param.h 1.34 95/11/05 SMI
                pirec.h 1.11 93/12/20 SMI
                mutex.h 1.14 94/07/29 SMI
                rwlock.h 1.3 94/07/29 SMI
                semaphore.h 1.4 94/07/29 SMI
                condvar.h 1.6 94/07/29 SMI
                cred.h 1.18 94/12/04 SMI
                uio.h 1.21 94/04/22 SMI
                seg_enum.h 1.1 93/04/03 SMI
                poll.h 1.19 94/08/31 SMI
                strmdep.h 1.8 92/07/14 SMI
                byteorder.h 1.9 94/01/04 SMI
                inet.h 1.8 92/07/14 SMI
                in_systm.h 1.4 93/02/04 SMI
                ip.h 1.4 93/08/18 SMI
                ip_icmp.h 1.2 93/02/04 SMI
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/ana_disk.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/cpu_mon.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/disk_mon.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/last_logs.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/mailq_l.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/proc_mon.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/sh_procs.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/swap_mon.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/vp_chk.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/mondbfile.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/dist_mon.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/ssp_chk.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/vcs_monitor.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/monitor/opcfwtmp.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/actions/mailq_pr.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/actions/st_inetd.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/actions/st_syslogd.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/actions/st_mail.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/actions/dist_del.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/cmds/opcdf.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/cmds/opclpst.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/cmds/opcps.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/cmds/E10000Log.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_NCS/cmds/ssp_config.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/opc_pkg.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/install/opcrclchk:
                HP OpenView VantagePoint for Sun Solaris A.06.11 (07
                        /09/02)
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/install/opcrdschk:
                HP OpenView VantagePoint for Sun Solaris A.06.11 (07
                        /09/02)
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/install/opcrndchk:
                HP OpenView VantagePoint for Sun Solaris A.06.11 (07
                        /09/02)
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/install/opcroschk:
                HP OpenView VantagePoint for Sun Solaris A.06.11 (07
                        /09/02)
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/install/opcrverchk:
                HP OpenView VantagePoint for Sun Solaris A.06.11 (07
                        /09/02)
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/install/opcrinst:
                HP OpenView VantagePoint for Sun Solaris A.06.11 (07
                        /09/02)
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/install/opcnsl:
                HP OpenView VantagePoint for Sun Solaris A.06.11 (07
                        /09/02)
                stdio.h 1.39 95/12/04 SMI
                feature_tests.h 1.7 94/12/06 SMI
                va_list.h 1.6 96/01/26 SMI
                types.h 1.38 95/11/14 SMI
                isa_defs.h 1.7 94/10/26 SMI
                machtypes.h 1.9 94/11/05 SMI
                select.h 1.10 92/07/14 SMI
                time.h 2.47 95/08/24 SMI
                time.h 1.23 95/08/28 SMI
                siginfo.h 1.36 95/08/24 SMI
                machsig.h 1.10 94/11/05 SMI
                socket.h 1.15 95/02/24 SMI
                netconfig.h 1.13 95/02/24 SMI
                sockio.h 1.11 93/10/26 SMI
                ioccom.h 1.10 92/07/14 SMI
                in.h 1.4 93/07/06 SMI
                stream.h 1.56 94/09/28 SMI
                vnode.h 1.54 98/10/09 SMI
                t_lock.h 1.42 94/11/02 SMI
                machlock.h 1.14 94/10/20 SMI
                dki_lkinfo.h 1.8 93/05/03 SMI
                dl.h 1.13 93/08/18 SMI
                sleepq.h 1.17 94/07/29 SMI
                turnstile.h 1.27 94/10/27 SMI
                param.h 1.34 95/11/05 SMI
                unistd.h 1.24 95/08/24 SMI
                pirec.h 1.11 93/12/20 SMI
                mutex.h 1.14 94/07/29 SMI
                rwlock.h 1.3 94/07/29 SMI
                semaphore.h 1.4 94/07/29 SMI
                condvar.h 1.6 94/07/29 SMI
                cred.h 1.18 94/12/04 SMI
                uio.h 1.21 94/04/22 SMI
                seg_enum.h 1.1 93/04/03 SMI
                poll.h 1.19 94/08/31 SMI
                strmdep.h 1.8 92/07/14 SMI
                byteorder.h 1.9 94/01/04 SMI
                netdb.h 1.17 97/12/23 SMI
                types.h 1.38 95/11/14 SMI
                feature_tests.h 1.7 94/12/06 SMI
                isa_defs.h 1.7 94/10/26 SMI
                machtypes.h 1.9 94/11/05 SMI
                select.h 1.10 92/07/14 SMI
                time.h 2.47 95/08/24 SMI
                time.h 1.23 95/08/28 SMI
                siginfo.h 1.36 95/08/24 SMI
                machsig.h 1.10 94/11/05 SMI
                types.h 1.38 95/11/14 SMI
                feature_tests.h 1.7 94/12/06 SMI
                isa_defs.h 1.7 94/10/26 SMI
                machtypes.h 1.9 94/11/05 SMI
                select.h 1.10 92/07/14 SMI
                time.h 2.47 95/08/24 SMI
                time.h 1.23 95/08/28 SMI
                siginfo.h 1.36 95/08/24 SMI
                machsig.h 1.10 94/11/05 SMI
                unistd.h 1.33 95/08/28 SMI
                unistd.h 1.24 95/08/24 SMI
                utsname.h 1.24 95/07/14 SMI
                errno.h 1.13 95/09/10 SMI
                errno.h 1.15 95/01/22 SMI
                in.h 1.4 93/07/06 SMI
                stream.h 1.56 94/09/28 SMI
                vnode.h 1.54 98/10/09 SMI
                t_lock.h 1.42 94/11/02 SMI
                machlock.h 1.14 94/10/20 SMI
                dki_lkinfo.h 1.8 93/05/03 SMI
                dl.h 1.13 93/08/18 SMI
                sleepq.h 1.17 94/07/29 SMI
                turnstile.h 1.27 94/10/27 SMI
                param.h 1.34 95/11/05 SMI
                pirec.h 1.11 93/12/20 SMI
                mutex.h 1.14 94/07/29 SMI
                rwlock.h 1.3 94/07/29 SMI
                semaphore.h 1.4 94/07/29 SMI
                condvar.h 1.6 94/07/29 SMI
                cred.h 1.18 94/12/04 SMI
                uio.h 1.21 94/04/22 SMI
                seg_enum.h 1.1 93/04/03 SMI
                poll.h 1.19 94/08/31 SMI
                strmdep.h 1.8 92/07/14 SMI
                byteorder.h 1.9 94/01/04 SMI
                socket.h 1.15 95/02/24 SMI
                netconfig.h 1.13 95/02/24 SMI
                sockio.h 1.11 93/10/26 SMI
                ioccom.h 1.10 92/07/14 SMI
                netdb.h 1.15 96/05/29 SMI
                types.h 1.38 95/11/14 SMI
                feature_tests.h 1.7 94/12/06 SMI
                isa_defs.h 1.7 94/10/26 SMI
                machtypes.h 1.9 94/11/05 SMI
                select.h 1.10 92/07/14 SMI
                time.h 2.47 95/08/24 SMI
                time.h 1.23 95/08/28 SMI
                siginfo.h 1.36 95/08/24 SMI
                machsig.h 1.10 94/11/05 SMI
                unistd.h 1.33 95/08/28 SMI
                unistd.h 1.24 95/08/24 SMI
                socket.h 1.15 95/02/24 SMI
                netconfig.h 1.13 95/02/24 SMI
                sockio.h 1.11 93/10/26 SMI
                ioccom.h 1.10 92/07/14 SMI
                ipc.h 1.15 94/09/03 SMI
                un.h 1.8 92/07/14 SMI
                netdb.h 1.15 96/05/29 SMI
                in.h 1.4 93/07/06 SMI
                stream.h 1.56 94/09/28 SMI
                vnode.h 1.54 98/10/09 SMI
                t_lock.h 1.42 94/11/02 SMI
                machlock.h 1.14 94/10/20 SMI
                dki_lkinfo.h 1.8 93/05/03 SMI
                dl.h 1.13 93/08/18 SMI
                sleepq.h 1.17 94/07/29 SMI
                turnstile.h 1.27 94/10/27 SMI
                param.h 1.34 95/11/05 SMI
                pirec.h 1.11 93/12/20 SMI
                mutex.h 1.14 94/07/29 SMI
                rwlock.h 1.3 94/07/29 SMI
                semaphore.h 1.4 94/07/29 SMI
                condvar.h 1.6 94/07/29 SMI
                cred.h 1.18 94/12/04 SMI
                uio.h 1.21 94/04/22 SMI
                seg_enum.h 1.1 93/04/03 SMI
                poll.h 1.19 94/08/31 SMI
                strmdep.h 1.8 92/07/14 SMI
                byteorder.h 1.9 94/01/04 SMI
                inet.h 1.8 92/07/14 SMI
                in_systm.h 1.4 93/02/04 SMI
                ip.h 1.4 93/08/18 SMI
                ip_icmp.h 1.2 93/02/04 SMI
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/ana_disk.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/cpu_mon.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/disk_mon.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/last_logs.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/mailq_l.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/proc_mon.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/sh_procs.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/swap_mon.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/vp_chk.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/mondbfile.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/dist_mon.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/ssp_chk.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/
                vcs_monitor.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/monitor/opcfwtmp.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/actions/mailq_pr.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/actions/st_inetd.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/actions/st_syslogd.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/actions/st_mail.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/actions/dist_del.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/cmds/opc_sec_v.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/cmds/opcdf.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/cmds/opclpst.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/cmds/opcps.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/cmds/E10000Log.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/A.06.11/RPC_DCE_TCP/cmds/ssp_config.sh.Z:
                None
        /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/
                solaris/AgentPlatform:
                None
        /var/opt/OV/share/tmp/OpC_appl/new_syslog/C/TEMPLATES/
                LOGFILE/logfile.dat:
                None
        /var/opt/OV/share/tmp/OpC_appl/new_syslog/C/new_sysl.idx:
                None
        /var/opt/OV/share/tmp/OpC_appl/new_syslog/ja_JP.SJIS/
                TEMPLATES/LOGFILE/logfile.dat:
                None
        /var/opt/OV/share/tmp/OpC_appl/new_syslog/ja_JP.SJIS/
                new_sysl.idx:
                None
        /opt/OV/OpC/examples/progs/Makef.solaris:
                None
        /opt/OV/OpC/examples/progs/Makef.solarisdce:
                OpC T.02.00 (08/30/93)

cksum(1) Output:
        2061327999 4252895 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/opc_pkg.Z
        2237779693 28090 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/install/
                opcrclchk
        3752962863 29760 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/install/
                opcrdschk
        3442561377 29793 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/install/
                opcrndchk
        3432754939 6462 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/install/
                opcroschk
        149297459 28472 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/install/
                opcrverchk
        991581781 132521 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/install/
                opcrinst
        4003991183 11164 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/install/
                opcnsl
        1220754222 2773 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
                ana_disk.sh.Z
        4280390360 6356 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
                cpu_mon.sh.Z
        2881416142 6536 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
                disk_mon.sh.Z
        4229255977 6240 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
                last_logs.sh.Z
        2408827558 6255 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
                mailq_l.sh.Z
        3848157904 6370 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
                proc_mon.sh.Z
        251849355 5868 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
                sh_procs.sh.Z
        1275846550 6141 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
                swap_mon.sh.Z
        3108378072 6094 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
                vp_chk.sh.Z
        851170547 14834 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
                mondbfile.sh.Z
        1901943676 6495 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
                dist_mon.sh.Z
        2351147485 6385 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
                ssp_chk.sh.Z
        2243064473 6975 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
                vcs_monitor.sh.Z
        3999310668 5520 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/monitor/
                opcfwtmp.Z
        3154234756 2567 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/actions/
                mailq_pr.sh.Z
        166264868 2663 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/actions/
                st_inetd.sh.Z
        4285343665 2666 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/actions/
                st_syslogd.sh.Z
        3472746591 2608 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/actions/
                st_mail.sh.Z
        4194304892 6515 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/actions/
                dist_del.sh.Z
        682661947 350 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/cmds/
                opcdf.Z
        2782906264 411 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/cmds/
                opclpst.Z
        190629175 425 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/cmds/
                opcps.Z
        867475868 4229 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/cmds/
                E10000Log.sh.Z
        261739739 4031 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_NCS/cmds/
                ssp_config.sh.Z
        506459518 6967631 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                opc_pkg.Z
        2237779693 28090 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                install/opcrclchk
        3752962863 29760 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                install/opcrdschk
        3442561377 29793 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                install/opcrndchk
        3432754939 6462 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                install/opcroschk
        149297459 28472 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                install/opcrverchk
        4091915525 132169 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                install/opcrinst
        4003991183 11164 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                install/opcnsl
        1220754222 2773 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                monitor/ana_disk.sh.Z
        4280390360 6356 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                monitor/cpu_mon.sh.Z
        2881416142 6536 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                monitor/disk_mon.sh.Z
        4229255977 6240 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                monitor/last_logs.sh.Z
        2408827558 6255 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                monitor/mailq_l.sh.Z
        3848157904 6370 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                monitor/proc_mon.sh.Z
        251849355 5868 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                monitor/sh_procs.sh.Z
        1275846550 6141 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                monitor/swap_mon.sh.Z
        3108378072 6094 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                monitor/vp_chk.sh.Z
        851170547 14834 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                monitor/mondbfile.sh.Z
        1901943676 6495 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                monitor/dist_mon.sh.Z
        2351147485 6385 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                monitor/ssp_chk.sh.Z
        2243064473 6975 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                monitor/vcs_monitor.sh.Z
        3343981619 20662 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                monitor/opcfwtmp.Z
        3154234756 2567 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                actions/mailq_pr.sh.Z
        166264868 2663 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                actions/st_inetd.sh.Z
        4285343665 2666 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                actions/st_syslogd.sh.Z
        3472746591 2608 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                actions/st_mail.sh.Z
        4194304892 6515 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/
                actions/dist_del.sh.Z
        2504716616 14033 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/cmds/
                opc_sec_v.sh.Z
        682661947 350 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/cmds/
                opcdf.Z
        2782906264 411 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/cmds/
                opclpst.Z
        190629175 425 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/cmds/
                opcps.Z
        867475868 4229 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/cmds/
                E10000Log.sh.Z
        261739739 4031 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/A.06.11/RPC_DCE_TCP/cmds/
                ssp_config.sh.Z
        2158188735 4368 /var/opt/OV/share/databases/OpC/mgd_node/
                vendor/sun/sparc/solaris/AgentPlatform
        2950102209 7107 /var/opt/OV/share/tmp/OpC_appl/new_syslog/C/
                TEMPLATES/LOGFILE/logfile.dat
        675288195 557 /var/opt/OV/share/tmp/OpC_appl/new_syslog/C/
                new_sysl.idx
        610799592 5231 /var/opt/OV/share/tmp/OpC_appl/new_syslog/
                ja_JP.SJIS/TEMPLATES/LOGFILE/logfile.dat
        1991845724 553 /var/opt/OV/share/tmp/OpC_appl/new_syslog/
                ja_JP.SJIS/new_sysl.idx
        1913040897 1058 /opt/OV/OpC/examples/progs/Makef.solaris
        4262292733 1239 /opt/OV/OpC/examples/progs/Makef.solarisdce

Patch Conflicts: None

Patch Dependencies: None

Hardware Dependencies: None

Other Dependencies: None

Supersedes:
        PHSS_22255 PHSS_22885 PHSS_23824

Equivalent Patches:
        ITOSOL_00158:
        sparcSOL: 2.6 2.7 2.8

        PHSS_27298:
        s700: 11.00
        s800: 11.00

Patch Package Size: 11950 KBytes

Installation Instructions:
        Please review all instructions and the Hewlett-Packard
        SupportLine User Guide or your Hewlett-Packard support terms
        and conditions for precautions, scope of license,
        restrictions, and, limitation of liability and warranties,
        before installing this patch.
        ------------------------------------------------------------
        1. Back up your system before installing a patch.

        2. Login as root.

        3. Copy the patch to the /tmp directory.

        4. Move to the /tmp directory and unshar the patch:

                cd /tmp
                sh PHSS_27297

        5a. For a standalone system, run swinstall to install the
            patch:

                swinstall -x autoreboot=true -x match_target=true \
                        -s /tmp/PHSS_27297.depot

        By default swinstall will archive the original software in
        /var/adm/sw/patch/PHSS_27297. If you do not wish to retain a
        copy of the original software, you can create an empty file
        named /var/adm/sw/patch/PATCH_NOSAVE.

        WARNING: If this file exists when a patch is installed, the
                 patch cannot be deinstalled. Please be careful
                 when using this feature.

        It is recommended that you move the PHSS_27297.text file to
        /var/adm/sw/patch for future reference.

        To put this patch on a magnetic tape and install from the
        tape drive, use the command:

                dd if=/tmp/PHSS_27297.depot of=/dev/rmt/0m bs=2k

Special Installation Instructions:
        NOTE: This patch contains an updated "Syslog (Solaris)"
              template. If you want to update the template in your
              DB, please enter:

              # opccfgupld -add -subentity new_syslog

              This will add the new conditions to the
              "Syslog (Solaris)" template.

              In the Admin GUI you can now remove the template
              "Kernel Logs (Solaris)" as the conditions from the
              default template "Kernel Logs (Solaris)" have been
              added to the template "Syslog (Solaris)". If you have
              modified the default "Kernel Logs (Solaris)" template
              you might want to compare the "Syslog" and the
              "Kernel Logs" template and decide whether you still
              need the "Kernel Logs" template or not.

        (A) Patch Installation Instructions
            -------------------------------

        (A1) Install the patch, following the standard installation
              instructions provided above under "Installation
              Instructions".

              Observe that you can use opc_backup(5) for backing up
              your system before installing a patch.

        NOTE: Make sure that no agent of the platform
              addressed by this patch is distributed (either
              from the ITO Administrator's GUI or from command
              line using inst.sh) while running swremove.

              If you are running VPO in a MC/ServiceGuard
              installation:

              - Note, that only files on the shared disk volume
                at /var/opt/OV/share will be patched. Therefore
                install the patch on one cluster node while the
                shared disks are mounted. The server processes
                may be running during patch installation.

              - It is not necessary to install this patch on all
                cluster nodes. Even if the software inventory on
                the other cluster nodes will not be updated, the
                patched files will be available there when the
                shared disk is switched to them.

        NOTE: This patch must be installed on the VPO Management
              Server system, NOT on an VPO Managed Node directly.
              Changes will take effect on managed nodes by means of
              VPO Software Distribution (using 'Force Update' if
              there is already an agent installed on the managed
              node). See chapter 2 of the VPO Administrator's
              Reference manual for more information.

        (B) Patch Deinstallation Instructions
            ---------------------------------

            NOTE: Make sure that no agent of the platform
                  addressed by this patch is distributed (either
                  from the ITO Administrator's GUI or from
                  command line using inst.sh) while running
                  swremove.

              If you are running VPO in a MC/ServiceGuard
              installation make sure to mount the shared
              disks at the node and only at the node that
              had them mounted during patch installation.
              Otherwise restoration of the original files
              onto the shared disk will fail.
-----End of Document ID: PHSS_27297------------------------------------------


Document ID: PHSS_28570
Date Loaded: 20030402
      Title: s700_800 10.X OV OB3.50 patch - CORE packet

Patch Name: PHSS_28570

Patch Description: s700_800 10.X OV OB3.50 patch - CORE packet

Creation Date: 03/03/31

Post Date: 03/04/02

Hardware Platforms - OS Releases:
        s700: 10.00 10.01 10.10 10.20
        s800: 10.00 10.01 10.10 10.20

Products:
        OmniBackII A.03.50

Filesets:
        OMNIBACK-II.OMNI-CORE-IS,A.03.50
        OMNIBACK-II.OMNI-CORE,A.03.50

Automatic Reboot?: No

Status: General Release

Critical: No

Path Name: /hp-ux_patches/s700_800/10.X/PHSS_28570

Symptoms:
        PHSS_28570:
        Id = HSLco39544 SR:H555009435
            Restore session on HP-UX with VXFS 3 reports error:

              "Cannot restore ACLs"

            for every file restored.

        Id = HSLco40537 SR:H555009863
            When backing up very large SAP databases with SSEA
            split mirror, backups can fail with error:

              "BR280I Time stamp <time>
               BR296I Split of mirror disks successful
               BR274E File /<sapdata_path>/system.data1 not found"

        PHSS_27589:
        Id = HSLco37266 SR: H555008830
            CORE patch breaks Oracle8 Integration functionality.

        PHSS_25819:
        Id = HSLco20414 SR: H555003134
            Device maintenance from command line is not sufficient.

        Id = HSLco27521 SR: H555005696
            During scheduled purge error message is displayed:

              "Bad catalog access for message #3137 in set 11".

        Id = HSLco27649 SR: H555005721
            Upgrade of AIX client fails with error:

              "Unexpected untar problem".

        Id = HSLco31142 SR: H555006771
            Load balancing is not working properly.

        Id = JAGad96899 SR: 8606227839
            Omniback II does not support Ext3 filesystem on
            Linux systems.

        PHSS_24429:
        Id = HSLco27823
            OmniBack II does not recognize Reiser filesystem on
            Linux.

        Id = HSLco26064
            Installation of OmniBack II clients on Linux 7.x
            systems does not complete.

        PHSS_23687:
        Id = NSMbb37117
            util_oracle8.exe complains that Oracle is not linked
            with OmniBack II for backup.

        Id = NSMex03956
            ".util ISINFO" returns corrupted bytes_to_be_received
            size.

        Id = HSLco23481
            Installation on HP-UX 11.20 systems does not complete.

        PHSS_22914:
        Id = NSMex03937
            User can gain an unauthorized access to an OmniBack
            client.

        Id = NSMex03757, NSMex03667
            Backup of one object fails with:

             "IPC Read Error. Connection reset by peer".

        PHSS_22434:
        Id = NSMex03372
            A backup of 129 Sybase databases fails with

              "[61:1005] Got unexpected close from INET on
               <hostname>.".

        Id = NSMex03638 SR: B554000768
            Omnidbutil's option "-change_objname" does not work
            properly.
              "[61:1005] Got unexpected close from INET on
               <hostname>.".

Defect Description:
        PHSS_28570:
        Id = HSLco39544
            If files are backed up on JFS filesystem and restored
            to VXFS filesystem, minor error is reported for every
            file restored.

        Resolution:
            Message "Destination file system does not support ACLs!"
            is added and is reported only once, subsequent error
            messages are suppressed.

        Id = HSLco40537
            In split mirror environment with very large SAP
            databases, it can happen that the size of the message
            buffer that OmniBack II uses is too small to fit in
            for the complete list of SAP files to be backed up.

        Resolution:
            New environment variable is introduced: OB2IPCBUFSIZE.
            In order to solve this problem, the buffer size can
            be increased by setting the OB2IPCBUFSIZE environment
            variable in the .omnirc file on CM, R1 and R2 hosts,
            specifying the desired amount of memory to be used
            for the buffer.

        PHSS_27589:
        Id = HSLco37266 SR: H555008830
            Omniback Core patch packets erroneously contain an
            outdated version of the libob2oracle8(_64bit).sl
            library.
            As a result, the correct version of this library
            is always overwritten by the old version when the
            Core patch is applied or another OmniBack II agent is
            installed on the Oracle8 system.

        Resolution:
           libob2oracle8(_64bit).sl is removed from the CORE
           package.

        PHSS_25819:
        Id = HSLco20414
            Device enabling, disabling and status report can not be
            performed using OmniBack II command line.

        Reslution:
            New options "-disable_device", "-enable_device" and
            "-device" are added to omnimm, omniupload and
            omnidownload. The appropriate messages are added to
            catalog.

            Part of SSPUX350_038.

        Id = HSLco27521
            The message 3137 is not defined in the catalog.

        Resolution:
            The appropriate message is added to catalog.

        Id = HSLco27649
            Shared libraries libdc and libde have to be removed
            before upgrade of AIX clients. Due to changes in
            OmniBack II linking process, extensions for the
            libraries are changed, so the libraries are not
            removed during the installation.

        Resolution:
            Correct shared libraries are removed during the
            upgrade process.

        Id = HSLco31142
            There is no warning reported when one creates a datalist
            or a barlist with load balancing enabled and minimum
            number of devices greater than number of configured
            logical devices.

        Resolution:
            Comparison of minimum and configured devices number
            is implemented and appropriate warning message is added
            to catalog.

        Id = JAGad96899
            Omniback II does not support Ext3 filesystem on
            Linux systems.

        Resolution:
            Omniback II supports Ext3 filesystem on Linux systems.

            Part of SSPUX350_065.

        PHSS_24429:
        Id = HSLco27823
            OmniBack II does not recognize Reiser filesystem om
            Linux systems.

        Resolution:
            OmniBack II recognizes Reiser filesystem.

        Id = HSLco26064
            OmniBack II client installation on Linux 7.x does not
            complete because of missing entries in /etc/xinetd.conf
            file.

        Resolution:
            Proper entries are added to /etc/xinetd.conf file
            during the installation of OmniBack II client on a
            Linux 7.x system.

        PHSS_23687:
        Id = NSMbb37117
            Library $ORACLE_HOME/lib/libobk.so is not properly
            linked and the error message is incorrect.

        Resolution:
            A proper message is added to message catalog.

        Id = NSMex03956
            Logging messages redirection does not work properly.

        Resolution:
            Exporting VUE variable is added.

        Id = HSLco23481
            Installation on HP-UX 11.20 systems does not complete.

        Resolution:
            Installation on HP-UX 11.20 systems completes.

        PHSS_22914:
        Id = NSMex03937
            User can gain access to an OmniBack client.

        Resolution:
            Code is changed.
            To preserve the previous behaviour, a variable must
            be set in the /opt/omni/.omnirc file (not recommended):

               OB2INETSECUEREXEC = 1

            Part of SSPUX350_022.

        Id = NSMex03757, NSMex03667
            Inet times out during the export of variables.

        Resolution:
            Environment variable OB2INETTIMEOUT is introduced. It
            should be set in /opt/omni/.omnirc file in form

              OB2INETTIMEOUT=<time_in_seconds>

            where time_in_seconds is timeout period for inet.
            Recommended value is 150.

            Part of SSPUX350_023.

        PHSS_22434:
        Id = NSMex03372
            Backup fails if there are more than 256 objects in a
            single barlist.

        Resolution:
            Number of objects in a barlist increased to 1024.

        Id = NSMex03638
            Omnidbutil's option "-change_objname" should not be a
            part of OmniBack II A.03.50.

        Resolution:
            Option "-change_objname" is removed.

SR:
        H555009863 H555009435 B554000887 B554000797 H555008830
        H555005696 H555003134 8606227839 H555006771 H555005721
        H555005779 H555005136 H555003879 H555004628 B555007579
        B554000503 B554000768

Patch Files:
        /opt/omni/databases/vendor/omnicf/hp/s800/hp-ux-1020/
                A.03.50/packet.Z
        /opt/omni/databases/vendor/omnicf/hp/s800/hp-ux-10/A.03.50/
                packet.Z
        /opt/omni/databases/vendor/omnicf/hp/s800/hp-ux-11/A.03.50/
                packet.Z
        /opt/omni/databases/vendor/omnicf/dec/alpha/osf1-4/A.03.50/
                packet.Z
        /opt/omni/databases/vendor/omnicf/gpl/i386/linux/A.03.50/
                packet.Z
        /opt/omni/databases/vendor/omnicf/ibm/rs6000/aix-42/A.03.50/