Neohapsis is currently accepting applications for employment. For more information, please visit our website www.neohapsis.com or email hr@neohapsis.com |
From: Francisco Jesus Monserrat Coll (francisco.monserrat
rediris.es)Date: Thu May 31 2001 - 14:17:15 CDT
Hello,
I'm having problem using the Immnunix RPM kernel package
for 2.2.19 with raid5.
Booting with a normal kernel (2.2.17) the md driver
initilized correctly and the raid5 is mounted, but when
I tried to boot the kernel 2.2.19 from the RPM packages
the driver is loaded, but nothing happen and the kernel
don't recognize the raid disks.
Below there is an extract of the booting process , have
anyone simmilar problems ?
Best regards
francisco monserrat
Linux 2.2.17
.........
md driver 0.90.0 MAX_MD_DEVS=256, MAX_REAL=12
raid5: measuring checksumming speed
raid5: KNI detected, trying cache-avoiding KNI checksum routine
pIII_kni : 1079.754 MB/sec
raid5: MMX detected, trying high-speed MMX checksum routines
pII_mmx : 1330.833 MB/sec
p5_mmx : 1415.034 MB/sec
8regs : 948.309 MB/sec
32regs : 543.687 MB/sec
using fastest function: p5_mmx (1415.034 MB/sec)
.......
autodetecting RAID arrays
autorun ...
... autorun DONE.
VFS: Mounted root (ext2 filesystem) readonly.
Freeing unused kernel memory: 76k freed
Adding Swap: 1052216k swap-space (priority -1)
(read) sdb's sb offset: 8971200 [events: 00000014]
(read) sdc's sb offset: 8971200 [events: 00000026]
(read) sdd's sb offset: 8971200 [events: 00000026]
autorun ...
considering sdd ...
adding sdd ...
adding sdc ...
adding sdb ...
created md0
bind<sdb,1>
bind<sdc,2>
bind<sdd,3>
running: <sdd><sdc><sdb>
now!
sdd's event counter: 00000026
sdc's event counter: 00000026
sdb's event counter: 00000014
md: superblock update time inconsistency -- using the most recent one
freshest: sdd
md: kicking non-fresh sdb from array!
unbind<sdb,2>
export_rdev(sdb)
raid5 personality registered
md0: max total readahead window set to 256k
md0: 2 data-disks, max readahead per data-disk: 128k
raid5: device sdd operational as raid disk 2
raid5: device sdc operational as raid disk 1
raid5: md0, not all disks are operational -- trying to recover array
raid5: allocated 3197kB for md0
raid5: raid level 5 set md0 active with 2 out of 3 devices, algorithm 2
RAID5 conf printout:
--------
linux 2.2.19 from kernel-smp-2.2.19-3_6.x_imnx
......
Floppy drive(s): fd0 is 1.44M
FDC 0 is a post-1991 82077
md driver 0.36.6 MAX_MD_DEV=4, MAX_REAL=8
scsi : 0 hosts.
scsi : detected total.
Partition check:
RAMDISK: Compressed image found at block 0
apm: BIOS version 1.2 Flags 0x0b (Driver version 1.13)
apm: disabled - APM is not SMP safe.
WireX/Immunix Scaffold v 0.2.6 initialized
SubDomain scaffold enabled.
..........
sdd:
scsi4 : AdvanSys SCSI 3.3D: PCI Ultra 16 CDB: IO ED00/F, IRQ 5
scsi : 5 hosts.
raid5 personality registered
VFS: Mounted root (ext2 filesystem) readonly.
change_root: old root has d_count=1
................
_______________________________________________
Immunix-users mailing list
Immunix-users
mail.wirex.com
http://mail.wirex.com/mailman/listinfo/immunix-users