> Hi,
>
> I don't quite understand why the distance from RT3 to Ia is 20 in Table 5 of
> RFC 2328. Can anyone tell me why?
>
> Thanks,
> Sam
Because Ia is advertised by RT10, so RT3 has a cost of 8 to get to RT6, a cost
of 7 to get to RT10 (15 so far) and then a cost of 5 to get to Ia, for a
total of 20.