Neohapsis is currently accepting applications for employment. For more information, please visit our website www.neohapsis.com or email hr@neohapsis.com |
From: Jerry Shenk (jas
DECNS.COM)Date: Fri Apr 06 2001 - 21:53:34 CDT
How do different switches handle high load. I think some of them throttle
the entire monitored VLAN to the speed of the span port and I think some
just drop packets going to the span port. Anybody know which switches
handle it which way.....or some other way.
-----Original Message-----
From: Focus on Intrusion Detection Systems
[mailto:FOCUS-IDS
SECURITYFOCUS.COM]On Behalf Of Scott Cothrell
Sent: Friday, April 06, 2001 7:51 PM
To: FOCUS-IDS
SECURITYFOCUS.COM
Subject: Re: Switch Configuration
For Catalyst 6K
Usage: set span disable [dest_mod/dest_port|all]
set span <src_mod/src_ports...|src_vlans...|sc0>
<dest_mod/dest_port> [rx|tx|both]
[inpkts <enable|disable>]
[learning <enable|disable>]
[multicast <enable|disable>]
[filter <vlans...>]
[create]
(example of src_mod/src_ports: 2/1-4 or 2/1-2 or 2/5,2/6
example of src_vlans: 2-10,105
> -----Original Message-----
> From: Focus on Intrusion Detection Systems
> [mailto:FOCUS-IDS
SECURITYFOCUS.COM]On Behalf Of Raul Rubio Rueda
> Sent: Friday, April 06, 2001 3:02 AM
> To: FOCUS-IDS
SECURITYFOCUS.COM
> Subject: Switch Configuration
>
>
> Sombody can tell me what i have to do to configure a Cisco
> switch port to
> put in it a IDS, i mean, which are the instruction??
>
> Thanks.
>
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]